Hearth and Home Technologies QVI-30FB-S owner manual Table of Contents

Page 3

Table of Contents

1 Listing and Code Approvals

A. Appliance Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

B. BTU Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

C. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 4

D. Non-Combustible Materials Specification. . . . . . . . . . . . . . 4

E. Combustible Materials Specification . . . . . . . . . . . . . . . . . 4

F. Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

2 Getting Started

A. Design and Installation Considerations . . . . . . . . . . . . . . . 5

B. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . . 5

C. Inspect Appliance and Components. . . . . . . . . . . . . . . . . . 5

3 Fireplace Size Requirements

A. Minimum Fireplace Opening . . . . . . . . . . . . . . . . . . . . . . . 6 B. Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

4 Termination Locations

A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . . 8

5 Vent Information and Diagrams

A. Vent Table Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

B. Horizontal Venting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

C. Measuring Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

6 Installation Preparation

A. Flue Damper. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 B. Chimney . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 C. Gas Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 D. Hearth or Hearth Extension . . . . . . . . . . . . . . . . . . . . . . . 10 E. Fireplace Conversion Notice . . . . . . . . . . . . . . . . . . . . . . 10 F. Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

7 Installing Vent Pipe and Appliance

A. Venting Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

B. Connecting Vent Pipe. . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

C. Placing, Securing and Leveling the Appliance . . . . . . . . . 12

D. Installing Adaptor and Termination Cap . . . . . . . . . . . . . . 13

8 Gas Information

A. Fuel Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

B. Gas Pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

9 Electrical Information

A. Wiring the Appliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 B. Junction Box Installation. . . . . . . . . . . . . . . . . . . . . . . . . . 17 C. Installation for Fan (Optional). . . . . . . . . . . . . . . . . . . . . . 17

10 Finishing

A. Mantel Projections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 B. Installing Trim Surrounds . . . . . . . . . . . . . . . . . . . . . . . . . 19

11 Appliance Setup

A. Remove Shipping Materials . . . . . . . . . . . . . . . . . . . . . . . 20

B. Clean the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

C. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

D. Ember Placement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

E. Positioning the Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

F. Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

G. Air Shutter Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

12 Operating Instructions

A. Before Lighting Appliance. . . . . . . . . . . . . . . . . . . . . . . . . 25 B. Lighting Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 C. Check Pilot Flame Appearance . . . . . . . . . . . . . . . . . . . . 27 D. After Appliance is Lit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 E. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . 28

13 Troubleshooting

A. Standing Pilot Ignition System . . . . . . . . . . . . . . . . . . . . . 29

14 Maintaining and Servicing Appliance

A. Maintenance Tasks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

15 Reference Materials

A. Appliance Dimension Diagram. . . . . . . . . . . . . . . . . . . . . 33

B. Vent Kits Components . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

C. Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

D. Limited Lifetime Warranty. . . . . . . . . . . . . . . . . . . . . . . . . 38

E. Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

= Contains updated information.

Quadra-FireQVI-30FB-S2020-910 Rev. F • 9/08

3

Image 3
Contents Commonwealth of Massachusetts ModelsModel Number Serial Number Homeowner Reference InformationTable of Contents Listing and Code Approvals Tools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsLocation Fireplace Size RequirementsMinimum Fireplace Opening Minimum fireplace opening requirements are shown in FigureClearances to Mantels or other Combustibles above Appliance ClearancesFoot minimum in snow regions Termination LocationsVent Termination Minimum Clearances Fire Risk Asphyxiation RiskMeasuring Standards Vent Information and DiagramsVent Table Key Horizontal VentingInstallation Preparation Reference instructions in the termination kit Installing Vent Pipe and ApplianceConnecting Vent Pipe Venting ComponentsPlacing, Securing and Leveling the Appliance Damper Flashing Kit Optional Installing Adaptor and Termination CapMasonry Factory Built Wood BurningGas Pressures Refer to for location of gas line access in ap- plianceGas Information Fuel Conversions Gas ConnectionHigh Altitude Installations Appliance Requirements Wiring the ApplianceON/OFF Switch Electrical InformationShock hazard Junction Box InstallationInstallation for Fan Optional Optional AccessoriesFAN Junction BOX Installing Trim Surrounds FinishingMantel Projections Ember Placement Appliance SetupClean the Appliance AccessoriesLog Assembly LOGS-QVI30FB Log PlacementPositioning the Logs Quadra-Fire QVI-30FB-S 2020-910 Rev. F 9/08 Quadra-Fire QVI-30FB-S 2020-910 Rev. F 9/08 Replacing Glass Assembly Glass AssemblyAir Shutter Setting Removing Glass AssemblyBefore operating this appliance have a qualified technician Operating InstructionsBefore Lighting Appliance This appliance has a Standing Pilot IgnitionStanding Pilot Ignition Lighting ApplianceDo not operate appliance with glass door removed Initial Break-in ProcedureCheck Pilot Flame Appearance After Appliance is LitFrequently Asked Questions Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionMaximum flame impingement. Follow lighting instruc Maintenance Tasks Maintaining and Servicing ApplianceRisk of injury or property damage Inspect Maintenance Tasks Reference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsEnding Manufacturing Date Log Set AssemblyService Parts Beginning Manufacturing Date OctService Parts List StockedAt Depot Be ordered from an authorized dealer Valve AssemblyCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Important operating Contact Information

QVI-30FB-S specifications

Hearth and Home Technologies has long been a leader in the hearth industry, and their QVI-30FB-S model continues that tradition with a modern twist. The QVI-30FB-S is an innovative gas fireplace that combines a stylish design with advanced technology, providing both warmth and ambiance to any home.

One of the standout features of the QVI-30FB-S is its sleek, contemporary design. With a clean face and large viewing area, this fireplace is perfect for today’s open living spaces. The minimalist aesthetic allows it to blend seamlessly into various décor styles, enhancing the overall look of the room while providing a focal point that captivates the eye.

The QVI-30FB-S utilizes cutting-edge heating technology to deliver efficient warmth. It boasts a high efficiency rating, which means it can effectively heat larger areas without excessive gas consumption. The gas burner system is designed to maximize heat while minimizing emissions, making it an environmentally friendly choice for homeowners looking to reduce their carbon footprint.

Another notable feature is the adjustable flame height. Users can customize the intensity of the flames, allowing for a cozy glow or a more robust fire, depending on their mood and the occasion. The fireplace also includes a backup battery system, ensuring that it remains functional even during power outages, providing peace of mind during inclement weather.

The QVI-30FB-S is equipped with an advanced control system, offering users the convenience of remote operation. With the included remote control, it's easy to adjust the temperature and flame height from anywhere in the room. Additionally, it has a smartphone-compatible option that allows for operation via a mobile app, adding another layer of convenience for tech-savvy users.

Safety is a priority with the QVI-30FB-S. It features a safety shut-off system that activates in the event of a malfunction or abnormal operation, ensuring that users can enjoy their fireplace worry-free.

In summary, the Hearth and Home Technologies QVI-30FB-S is a remarkable gas fireplace that combines style, efficiency, and modern technology. Its design elements, heating capabilities, adjustable features, and safety systems make it an excellent choice for homeowners looking to enhance their living spaces with warmth and elegance.