Hearth and Home Technologies QVI-30FB-S owner manual Inspect Maintenance Tasks

Page 32

Inspect

 

Maintenance Tasks

 

 

 

Doors, Surrounds

1.

Assess condition of screen and replace as necessary. Recommend addition of screen if one is not present.

and Fronts

 

 

2.

Inspect for scratches, dents or other damage and repair as necessary.

 

 

 

 

 

3.

Verify no obstructions to airflow through the louvers.

 

 

 

 

4.

Verify maintenance of proper clearance to combustible household objects.

 

 

 

Gasket Seal, Glass

1.

Inspect gasket seal and its condition.

Assembly and Glass

 

 

2.

Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat.

 

 

 

 

 

3.

Confirm there is no damage to glass or glass frame. Replace as necessary.

 

 

 

 

4.

Verify that latches engage properly, clip studs are not stripped, and glass attachment components are

 

 

intact and operating properly. Replace as necessary.

 

5.

Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot be removed.

 

 

 

Valve Compartment

1.

Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw

and Firebox Top

 

tips that have penetrated the sheet metal are sharp and should be avoided.

 

 

 

 

2.

Remove any foreign objects.

 

 

 

 

3.

Verify unobstructed air circulation.

 

 

 

Logs

1.

Inspect for broken, damaged, or missing logs. Replace as necessary.

 

 

 

 

2.

Verify correct log placement and no flame impingement causing sooting. Correct as necessary.

 

 

 

Firebox

1.

Inspect for paint condition, warpage, corrosion or perforation. Contact Dealer for inspection.

 

 

 

 

2.

Replace appliance if firebox has been perforated.

 

 

 

Burner Ignition and

1.

Verify burner is properly secured and aligned with pilot or igniter.

Operation

 

 

2.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary.

 

 

 

 

 

3.

Replace ember materials with new dime-size and shape pieces. Do not block ports or obstruct lighting paths.

 

 

 

 

4.

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

 

 

 

5.

Inspect for lifting or other flame problems.

 

 

 

 

6.

Verify air shutter is clear of dust and debris.

 

 

 

 

7.

Inspect orifice for soot, dirt or corrosion.

 

 

 

 

8.

Verify manifold and inlet pressures. Adjust regulator as required.

 

 

 

 

9.

Inspect pilot flame strength. Clean or replace orifice as necessary.

 

 

 

 

10.

Inspect thermocouple/thermopile or IPI sensor rod for soot, corrosion and deterioration. Clean with emery

 

 

cloth or replace as required.

 

 

 

11. Verify millivolt output. Replace as necessary.

 

 

 

Venting

1.

Inspect venting for blockage or obstruction such as bird nests, leaves, etc.

 

 

 

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

 

 

 

3.

Verify that termination cap clearance to subsequent construction (building additions, decks, fences or

 

 

sheds) has been maintained.

 

 

 

 

4.

Inspect for corrosion or separation.

 

 

 

 

5.

Verify weather stripping, sealing and flashing remains intact.

 

 

 

 

6.

Inspect draft shield to verify it is not bent, damaged or missing.

 

 

 

Remote controls

1.

Verify operation of remote.

 

 

 

 

2.

Replace batteries in remote transmitters and battery-powered receivers.

 

 

 

 

3.

Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure

 

 

or leaking.

32

Quadra-FireQVI-30FB-S2020-910 Rev. F • 9/08

Image 32
Contents Models Commonwealth of MassachusettsHomeowner Reference Information Model Number Serial NumberTable of Contents Listing and Code Approvals Design and Installation Considerations Getting StartedInspect Appliance and Components Tools and Supplies NeededFireplace Size Requirements Minimum Fireplace OpeningMinimum fireplace opening requirements are shown in Figure LocationClearances Clearances to Mantels or other Combustibles above ApplianceTermination Locations Vent Termination Minimum ClearancesFire Risk Asphyxiation Risk Foot minimum in snow regionsVent Information and Diagrams Vent Table KeyHorizontal Venting Measuring StandardsInstallation Preparation Installing Vent Pipe and Appliance Connecting Vent PipeVenting Components Reference instructions in the termination kitPlacing, Securing and Leveling the Appliance Installing Adaptor and Termination Cap MasonryFactory Built Wood Burning Damper Flashing Kit OptionalRefer to for location of gas line access in ap- pliance Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Wiring the Appliance ON/OFF SwitchElectrical Information Appliance RequirementsJunction Box Installation Installation for Fan OptionalOptional Accessories Shock hazardFAN Junction BOX Mantel Projections Installing Trim SurroundsFinishing Appliance Setup Clean the ApplianceAccessories Ember PlacementPositioning the Logs Log Assembly LOGS-QVI30FBLog Placement Quadra-Fire QVI-30FB-S 2020-910 Rev. F 9/08 Quadra-Fire QVI-30FB-S 2020-910 Rev. F 9/08 Glass Assembly Air Shutter SettingRemoving Glass Assembly Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceThis appliance has a Standing Pilot Ignition Before operating this appliance have a qualified technicianLighting Appliance Standing Pilot IgnitionInitial Break-in Procedure Check Pilot Flame AppearanceAfter Appliance is Lit Do not operate appliance with glass door removedFrequently Asked Questions Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Maximum flame impingement. Follow lighting instruc TroubleshootingSymptom Possible Cause Corrective Action Risk of injury or property damage Maintenance TasksMaintaining and Servicing Appliance Inspect Maintenance Tasks Appliance Dimension Diagram Reference MaterialsVent Kits Components Direct Vent Flex Liner KitsLog Set Assembly Service PartsBeginning Manufacturing Date Oct Ending Manufacturing DateAt Depot Service Parts ListStocked Valve Assembly Be ordered from an authorized dealerCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information Important operating

QVI-30FB-S specifications

Hearth and Home Technologies has long been a leader in the hearth industry, and their QVI-30FB-S model continues that tradition with a modern twist. The QVI-30FB-S is an innovative gas fireplace that combines a stylish design with advanced technology, providing both warmth and ambiance to any home.

One of the standout features of the QVI-30FB-S is its sleek, contemporary design. With a clean face and large viewing area, this fireplace is perfect for today’s open living spaces. The minimalist aesthetic allows it to blend seamlessly into various décor styles, enhancing the overall look of the room while providing a focal point that captivates the eye.

The QVI-30FB-S utilizes cutting-edge heating technology to deliver efficient warmth. It boasts a high efficiency rating, which means it can effectively heat larger areas without excessive gas consumption. The gas burner system is designed to maximize heat while minimizing emissions, making it an environmentally friendly choice for homeowners looking to reduce their carbon footprint.

Another notable feature is the adjustable flame height. Users can customize the intensity of the flames, allowing for a cozy glow or a more robust fire, depending on their mood and the occasion. The fireplace also includes a backup battery system, ensuring that it remains functional even during power outages, providing peace of mind during inclement weather.

The QVI-30FB-S is equipped with an advanced control system, offering users the convenience of remote operation. With the included remote control, it's easy to adjust the temperature and flame height from anywhere in the room. Additionally, it has a smartphone-compatible option that allows for operation via a mobile app, adding another layer of convenience for tech-savvy users.

Safety is a priority with the QVI-30FB-S. It features a safety shut-off system that activates in the event of a malfunction or abnormal operation, ensuring that users can enjoy their fireplace worry-free.

In summary, the Hearth and Home Technologies QVI-30FB-S is a remarkable gas fireplace that combines style, efficiency, and modern technology. Its design elements, heating capabilities, adjustable features, and safety systems make it an excellent choice for homeowners looking to enhance their living spaces with warmth and elegance.