Before making gas connections ensure that appliance be- ing installed is compatible with the available gas type.

Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a qualified technician using Hearth & Home Technologies specified and approved parts.

Note: Have the gas supply line installed in accordance with local building codes, if any. If not, follow ANSI

223.1.Installation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter).

B. Gas Pressures

Proper input pressures are required for optimum appli- ance performance. Gas line sizing requirements need to be made following NFPA54.

WARNING

Fire Risk. Explosion Hazard.

High pressure will damage valve.

• Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig.

Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig.

WARNING

Verify inlet pressures.

• High pressure may cause overfire condition.

• Low pressure may cause explosion.

Verify minimum pressures when other household gas appliances are operating.

Install regulator upstream of valve if line pressure is greater than 1/2 psig.

Pressure requirements for appliance are shown in the table below. Minimum pressures must be met when other household gas appliances are operating.

Pressure

Natural Gas

Propane

Minimum inlet pressure

5.0 inches

11.0 inches

w.c.

w.c.

 

Maximum inlet gas pressure

14.0 inches

14.0 inches

w.c.

w.c.

 

Manifold pressure

3.5 inches

10.0 inches

w.c.

w.c.

 

NOTE: A listed (and Commonwealth of Massachusetts ap- proved) 1/2 inch (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 inch (13 mm) control valve inlet.

If substituting for these components, please consult local codes for compliance.

Refer to Section 15 for location of gas line access in ap- pliance.

NOTE: Gas line may be run from either side of the appliance provided the hole in the outer wrap does NOT exceed 2-1/2 inches in diameter and does not penetrate the firebox.

WARNING

Gas Leak Risk

Support control when attaching pipe to prevent bending gas line.

NOTE: The gap between supply piping and gas access hole may be caulked with high temperature caulk or stuffed with non-combustible, unfaced insulation to prevent cold air infiltration.

Ensure that gas line does not come in contact with outer wrap of appliance. Follow local codes.

Incoming gas line should be piped into the valve compartment and connected to the 1/2 inch connection on the manual shutoff valve.

Check all fittings and connections of appliance which may have loosened during shipping.

Quadra-FireQVI-25FB-S2031-910 Rev. E • 9/08

15

Image 15
Contents Model What to do if you smell gasHOT Surfaces Xxxxxxxx Homeowner Reference InformationTable of Contents Listing and Code Approvals Tools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsMinimum Fireplace Opening Fireplace Size RequirementsClearances to Mantels or other Combustibles above Appliance ClearancesVent Termination Minimum Clearances Termination LocationsMeasuring Standards Vent Information and DiagramsVent Table Key Horizontal VentingInstallation Preparation Installing Vent Pipe and Appliance Connecting Vent PipeVenting Components Class a Wood Pipe Inlet AIR Vent Pipe Stainless Steel Placing, Securing and Leveling the Appliance Damper Flashing Kit Optional Installing Adaptor and Termination CapMasonry Factory Built Wood BurningGas Information Fuel Conversions Gas ConnectionGas Pressures Check for GAS Leaks High Altitude InstallationsAppliance Requirements Wiring the ApplianceON/OFF Switch Electrical InformationJunction Box Installation Installation for Fan OptionalOptional Accessories Fan Wiring Diagram Mantel Projections FinishingEmber Placement Appliance SetupClean the Appliance AccessoriesLog Set Assembly LOGS-2031 Log PlacementPositioning the Logs Quadra-Fire QVI-25FB-S 2031-910 Rev. E 9/08 Replacing Glass Assembly Glass AssemblyAir Shutter Setting Removing Glass AssemblyOperating Instructions Before Lighting ApplianceBefore operating this appliance have a qualified technician Lighting Appliance Standing Pilot IgnitionWhat to do if YOU Smell GAS After Appliance is Lit Initial Break-in ProcedurePilot Adjustment Check Pilot Flame AppearanceIssue Solutions Frequently Asked QuestionsTroubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingMaintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksAppliance Dimension Diagram QVI-25FB-S Model DimensionsReference Materials Direct Vent Flex Liner Kits Vent Kits ComponentsPart number list on following Log Set AssemblyService Parts List 119 1312Service Parts StockedAt Depot Valve Assembly CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

QVI-25FB-S specifications

Hearth and Home Technologies has carved a niche for itself in the realm of modern heating solutions, and the QVI-25FB-S fireplace is a testament to their commitment to innovation, efficiency, and aesthetic appeal. This model brings together cutting-edge technologies and design elements that elevate any living space, combining functionality with style.

The QVI-25FB-S is a direct vent gas fireplace insert, which means it can be installed into an existing fireplace or new construction. One of its standout features is its aesthetic versatility, available in multiple finishes and styles to fit seamlessly into various home decors. Its clean, contemporary lines and realistic flame presentation create an inviting ambiance, making it a perfect focal point in any room.

This model excels in energy efficiency, boasting an impressive efficiency rating. It utilizes advanced combustion technology that ensures minimal energy wastage while providing consistent heat output. The direct venting system is designed to draw air from outside, making it a great choice for energy-conscious homeowners looking to reduce their heating bills without sacrificing comfort.

One of the hallmark features of the QVI-25FB-S is its user-friendly interface. Equipped with a simplified remote control, this fireplace enables easy adjustment of flame height and heat output, catering to the user's comfort preferences. This allows for maximum convenience, whether you want to create a cozy atmosphere on a chilly night or provide moderate warmth during cooler seasons.

For safety and reliability, the QVI-25FB-S includes several important safety features. An automatic shut-off system ensures the unit will turn off if it detects any irregularities. Additionally, its glass front comes with a safety screen to prevent accidental contact with the hot surface, making it an ideal choice for homes with children or pets.

The QVI-25FB-S also supports eco-conscious lifestyles. By utilizing natural or propane gas, it produces lower emissions compared to traditional wood-burning fireplaces, making it a cleaner option for heating. The fireplace's innovative design minimizes pollutants while maximizing heat output, aligning perfectly with sustainable living practices.

In conclusion, the Hearth and Home Technologies QVI-25FB-S fireplace insert is a superior choice for those seeking an efficient, stylish, and user-friendly heating solution. With its advanced technology, safety features, and environmental considerations, it is well-suited for today’s modern home, delivering warmth and elegance year-round. Whether you are remodeling or building anew, this fireplace promises to be a stunning and practical addition to your living space.