Hearth and Home Technologies QVI-25FB-S owner manual Clearances

Page 7

B. Clearances

WARNING

Fire Risk.

Odor Risk.

• Clearance to combustible material under the insert is 1/4 inch (0.6 cm).

Use leveling legs to raise insert minimum 1/4 inch above combustible material or outer wrap of factory built firebox.

WARNING

Fire Risk.

• Locate and install appliance to all clearance specifications in manual.

MANTEL

12 in. MAX.

12 in. MAX.

TOP OF UNIT

Figure 3.2 Clearances to Mantels or other Combustibles above Appliance

Quadra-FireQVI-25FB-S2031-910 Rev. E • 9/08

7

Image 7 Contents
What to do if you smell gas ModelHOT Surfaces Xxxxxxxx Homeowner Reference Information Table of Contents Listing and Code Approvals Tools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsMinimum Fireplace Opening Fireplace Size RequirementsClearances to Mantels or other Combustibles above Appliance ClearancesVent Termination Minimum Clearances Termination LocationsMeasuring Standards Vent Information and DiagramsVent Table Key Horizontal VentingInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVenting Components Class a Wood Pipe Inlet AIR Vent Pipe Stainless Steel Placing, Securing and Leveling the Appliance Damper Flashing Kit Optional Installing Adaptor and Termination CapMasonry Factory Built Wood BurningFuel Conversions Gas Connection Gas InformationGas Pressures Check for GAS Leaks High Altitude InstallationsAppliance Requirements Wiring the ApplianceON/OFF Switch Electrical InformationInstallation for Fan Optional Junction Box InstallationOptional Accessories Fan Wiring Diagram Mantel Projections FinishingEmber Placement Appliance SetupClean the Appliance AccessoriesLog Placement Log Set Assembly LOGS-2031Positioning the Logs Quadra-Fire QVI-25FB-S 2031-910 Rev. E 9/08 Replacing Glass Assembly Glass AssemblyAir Shutter Setting Removing Glass AssemblyBefore Lighting Appliance Operating InstructionsBefore operating this appliance have a qualified technician Standing Pilot Ignition Lighting ApplianceWhat to do if YOU Smell GAS After Appliance is Lit Initial Break-in ProcedurePilot Adjustment Check Pilot Flame AppearanceIssue Solutions Frequently Asked QuestionsSymptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingMaintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksQVI-25FB-S Model Dimensions Appliance Dimension DiagramReference Materials Direct Vent Flex Liner Kits Vent Kits ComponentsPart number list on following Log Set AssemblyService Parts List 119 1312Stocked Service PartsAt Depot Valve Assembly CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information