Hearth and Home Technologies QVI-25FB-S Maintaining and Servicing Appliance, Maintenance Tasks

Page 31

14 Maintaining and Servicing Appliance

A. Maintenance Tasks

Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualified service technician should perform an appliance checkup at the beginning of each heating season.

WARNING

Risk of injury or property damage.

Before servicing:

Turn off gas.

Turn off electricity to appliance.

Disable remote control, if one is present.

Ensure appliance is completely cooled.

After servicing:

Replace any screen or barrier that was removed.

Reseal and reinstall any venting removed for servicing.

WARNING

Annual inspection by qualified technician recommended.

Check:

Condition of doors, surrounds and fronts.

Condition of glass, glass assembly and glass seal.

Obstructions of combustion and ventilation air.

Condition of logs.

Condition of firebox.

Burner ignition and operation.

Burner air shutter adjustment

Gas connections and fittings.

Obstructions of termination cap.

Clean:

• Glass

Air passageways, grilles, control compartment

Burner, burner ports

Risk of:

Fire

Delayed ignition or explosion

Exposure to combustion fumes

Odors

CAUTION

Handle glass assembly with care.

NOTE: Clean glass after initial 3-4 hours operation.

Longer operation without cleaning glass may cause a permanent white film on glass.

When cleaning glass door:

Avoid striking, scratching or slamming glass.

Do NOT use abrasive cleaners.

Use a hard water deposit glass cleaner on white film.

Do NOT clean glass when hot.

Turn off appliance after 3-4 hours of operation and

ALLOW TO COOL.

Remove and clean glass assembly.

Replace glass assembly and operate appliance for additional 12 hours.

Refer to maintenance instructions.

WARNING

Inspect external vent cap regularly.

Ensure no debris blocks cap.

Combustible materials blocking cap may ignite.

Restricted air flow affects burner operation.

Quadra-FireQVI-25FB-S2031-910 Rev. E • 9/08

31

Image 31
Contents What to do if you smell gas ModelHOT Surfaces Xxxxxxxx Homeowner Reference InformationTable of Contents Listing and Code Approvals Tools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsMinimum Fireplace Opening Fireplace Size RequirementsClearances to Mantels or other Combustibles above Appliance ClearancesVent Termination Minimum Clearances Termination LocationsMeasuring Standards Vent Information and DiagramsVent Table Key Horizontal VentingInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVenting Components Class a Wood Pipe Inlet AIR Vent Pipe Stainless Steel Placing, Securing and Leveling the Appliance Damper Flashing Kit Optional Installing Adaptor and Termination CapMasonry Factory Built Wood BurningFuel Conversions Gas Connection Gas InformationGas Pressures Check for GAS Leaks High Altitude InstallationsAppliance Requirements Wiring the ApplianceON/OFF Switch Electrical InformationInstallation for Fan Optional Junction Box InstallationOptional Accessories Fan Wiring Diagram Mantel Projections FinishingEmber Placement Appliance SetupClean the Appliance AccessoriesLog Placement Log Set Assembly LOGS-2031Positioning the Logs Quadra-Fire QVI-25FB-S 2031-910 Rev. E 9/08 Replacing Glass Assembly Glass AssemblyAir Shutter Setting Removing Glass AssemblyBefore Lighting Appliance Operating InstructionsBefore operating this appliance have a qualified technician Standing Pilot Ignition Lighting ApplianceWhat to do if YOU Smell GAS After Appliance is Lit Initial Break-in ProcedurePilot Adjustment Check Pilot Flame AppearanceIssue Solutions Frequently Asked QuestionsSymptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingMaintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksQVI-25FB-S Model Dimensions Appliance Dimension DiagramReference Materials Direct Vent Flex Liner Kits Vent Kits ComponentsPart number list on following Log Set AssemblyService Parts List 119 1312Stocked Service PartsAt Depot Valve Assembly CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

QVI-25FB-S specifications

Hearth and Home Technologies has carved a niche for itself in the realm of modern heating solutions, and the QVI-25FB-S fireplace is a testament to their commitment to innovation, efficiency, and aesthetic appeal. This model brings together cutting-edge technologies and design elements that elevate any living space, combining functionality with style.

The QVI-25FB-S is a direct vent gas fireplace insert, which means it can be installed into an existing fireplace or new construction. One of its standout features is its aesthetic versatility, available in multiple finishes and styles to fit seamlessly into various home decors. Its clean, contemporary lines and realistic flame presentation create an inviting ambiance, making it a perfect focal point in any room.

This model excels in energy efficiency, boasting an impressive efficiency rating. It utilizes advanced combustion technology that ensures minimal energy wastage while providing consistent heat output. The direct venting system is designed to draw air from outside, making it a great choice for energy-conscious homeowners looking to reduce their heating bills without sacrificing comfort.

One of the hallmark features of the QVI-25FB-S is its user-friendly interface. Equipped with a simplified remote control, this fireplace enables easy adjustment of flame height and heat output, catering to the user's comfort preferences. This allows for maximum convenience, whether you want to create a cozy atmosphere on a chilly night or provide moderate warmth during cooler seasons.

For safety and reliability, the QVI-25FB-S includes several important safety features. An automatic shut-off system ensures the unit will turn off if it detects any irregularities. Additionally, its glass front comes with a safety screen to prevent accidental contact with the hot surface, making it an ideal choice for homes with children or pets.

The QVI-25FB-S also supports eco-conscious lifestyles. By utilizing natural or propane gas, it produces lower emissions compared to traditional wood-burning fireplaces, making it a cleaner option for heating. The fireplace's innovative design minimizes pollutants while maximizing heat output, aligning perfectly with sustainable living practices.

In conclusion, the Hearth and Home Technologies QVI-25FB-S fireplace insert is a superior choice for those seeking an efficient, stylish, and user-friendly heating solution. With its advanced technology, safety features, and environmental considerations, it is well-suited for today’s modern home, delivering warmth and elegance year-round. Whether you are remodeling or building anew, this fireplace promises to be a stunning and practical addition to your living space.