Hearth and Home Technologies SL-550TR-E Maintenance and Service, Doors, Surrounds, Fronts

Page 15

3 Maintenance and Service

Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace.

When properly maintained, your fireplace will give you many years of trouble-free service. We recommend an- nual service by a qualified service technician.

Doors, Surrounds, Fronts

Frequency: Annually

By: Homeowner

Tools needed: Protective gloves, stable work surface

• Assess condition of screen and replace as necessary.

A. Maintenance Tasks-Homeowner

Installation and repair should be done by a qualified service technician only. The fireplace should be inspected before use and at least annually by a professional service person.

The following tasks may be performed annually by the homeowner. If you are uncomfortable performing any of the listed tasks, please call your dealer for a service ap- pointment.

More frequent cleaning may be required due to lint from carpeting or other factors. Control compartment, burner and circulating air passageway of the fireplace must be kept clean.

CAUTION! Risk of Burns! The fireplace should be turned off and cooled before servicing.

Glass Cleaning

Frequency: Seasonally

By: Homeowner

Tools Needed: Protective gloves, glass cleaner, drop cloth and a stable work surface.

CAUTION! Handle fixed glass assembly with care. Glass is breakable.

Avoid striking, scratching or slamming glass

Avoid abrasive cleaners

DO NOT clean glass while it is hot

Prepare a work area large enough to accommodate fixed glass assembly and door frame by placing a drop cloth on a flat, stable surface.

Note: Fixed glass assembly and gasketing may have res- idue that can stain carpeting or floor surfaces.

Remove door or decorative front from fireplace and set aside on work surface.

See Section 14.G for instructions to remove fixed glass assembly.

Clean glass with a non-abrasive commercially available cleaner.

-Light deposits: Use a soft cloth with soap and water

-Heavy deposits: Use commercial fireplace glass cleaner (consult with your dealer)

Carefully set fixed glass assembly in place on fireplace. Hold glass in place with one hand and secure glass latches with the other hand.

Reinstall door or decorative front.

Inspect for scratches, dents or other damage and repair as necessary.

Check that louvers are not blocked.

Vacuum and dust surfaces.

Remote Control

Frequency: Seasonally

By: Homeowner

Tools needed: Replacement batteries and remote con- trol instructions.

Locate remote control transmitter and receiver.

Verify operation of remote. Refer to remote control operation instructions for proper calibration and setup procedure.

Place batteries as needed in remote transmitters and battery-powered receivers.

Place remote control out of reach of children.

If not using your fireplace for an extended period of time (summer months, vacations/trips, etc), to prevent unin- tended operation:

Remove batteries from remote controls.

Unplug 3 volt adapter plug on IPI models.

Heat & Glo • SL-550 / 750 / 950TR-E2118-900 Rev. L • 11/08

15

Image 15
Contents HOT Surfaces What to do if you smell gasCongratulations Homeowner Reference InformationXxxxxxxx User Guide Table of ContentsReference Materials Appliance SetupTroubleshooting FinishingCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Tempered Glass Specifications High Altitude InstallationsListing and Code Approvals Appliance CertificationC22.1 Non-Combustible Materials SpecificationCombustible Materials Specification Electrical CodesRequirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsHeat & Glo SL-550 / 750 / 950TR-E 2118-900 Rev. L 11/08 Gas Fireplace SafetyOperating Instructions User Guide Your FireplaceClear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalWhat to do if YOU Smell GAS To light the burner, flip the ON/OFF switch toLighting Instructions IPI Final inspection byLighting Instructions Standing Pilot Frequently Asked Questions Issue SolutionsAfter Fireplace is Lit Remote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningLogs Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection VentingEither cobrahead or SIT Typical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Selecting Appliance Location Framing and ClearancesConstructing the Appliance Chase ClearancesModels Mantel Leg Acceptable on both sides of opening Mantel and Wall ProjectionsTermination Locations Vent Termination Minimum ClearancesOpening = Vent Terminal = AIR Supply Inlet = Area Where Terminal is not PermittedUse of Elbows Vent Information and DiagramsApproved Pipe Vent Table KeyUse of Flex Vent Minimum Maximum Minimum Top Vent Horizontal Termination Venting with 2 elbowsV1 Minimum H1 + H2 Maximum Venting with 3 elbowsExhaust restrictor Instructions Top Vent Vertical Termination No Elbows V1 = 60 ft. Max .3 mSL-550TR-E SL-750TR-E SL-950TR-E Top Vent Vertical Termination Venting with 2 elbowsMIN SL-550TR-E SL-750TR-E SL-950TR-E Top Vent Vertical Termination Venting with 3 elbowsV1 MIN H1 MAX V2 MIN H2 MAX V3 MIN Top Vent Vertical Termination Venting with 4 elbowsRear Vent Horizontal Termination No Elbows Rear Vent Horizontal Termination One 45º ElbowH1 = 9 in mm Maximum H2 + H3 MAX H1 + H2+ H3 MAX Rear Vent Horizontal Termination Venting with 2 elbowsRear Vent Horizontal Termination Venting with 3 elbows H1 + H2 MAXRear Vent Vertical Termination Venting with 1 elbow Rear Vent Vertical Termination Venting with 2 elbows+ H 2 MAX MIN MIN MAX + H 2 MAX Rear Vent Vertical Termination Venting with 3 elbowsCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingInstalling Ceiling Firestop Install the Ceiling FirestopInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Top Vent Appliance PreparationCut the metal retaining band and fold the sides out Rear Vent13 Proper Positioning and Securing of an Appliance Securing and Leveling the ApplianceAssemble Pipe Sections Installing Vent Pipe DVP and SLP PipeAttach Vent to the Firebox Assembly Assemble Vent Sections DVP Pipe OnlyAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarFoot minimum in snow regions 18 Secure Pipe with SLP-FS Install RF4-8Install Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap DVP and SLP Pipe Ansi Z223.1 and CAN/CGA-B149 installation codesRefer to of this manual Gas Connection Gas InformationFuel Conversion Gas PressureOptional Accessories Requirements Wiring RequirementsIntellifire Ignition System Wiring Standing Pilot Ignition System WiringIntellifire Ignition Wiring Diagram with Remote Receiver Standing Pilot Ignition Wiring Diagram Electrical Service and RepairWall Switch Installation for Fan Optional Junction Box InstallationFinishing Facing Materials Facing MaterialSplatter Guard To install the Splatter GuardTo Remove the Splatter Guard To Close the Lower Access PanelFinishing Clearances for Aero, Chad and Halston Fronts DoorsElevated Hearth Systems Appliance Setup Install the Log Assembly SRV2115-701 SRV2118-701 SRV2121-701 Install Trim and/or Surround Air Shutter SettingShutter Settings Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Ues to spark, and main Appliance Dimension Diagram Reference MaterialsInches Millimeters P 4 5 4 5 E lb o w Vent Components DiagramsDVP vent components DVP-TRAPDVP-TRAPFL RF6M RF12MBEK DVP-BEK2 COOL-ADDFor use with IPI and DSI appliances only DVP-TVHWDVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP SLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAPDVP-TB1 Roof Flashing Ceiling Firestop ElbowExtended Heat Shield RF4-8Snorkel Black Support Box-Black Wall Thimble-BlackAdapter Service Parts Log Set AssemblyService Parts List SL-550TR-E, SL-550TR-IPI-E StockedAt Depot SL-750TR-E, SL-750TR-IPI-E Stocked Service Parts ListSL-950TR-E, SL-950TR-IPI-E GLA-950TR Service Parts List SL-950TR-E, SL-950TR-IPI-EDescription Serial # Part Number SL-550 / 750 / 950TR-IPI-EDescription Comments Part Number Standing Pilot Valve AssemblyContact Information

SL-750TR-E, SL-750TR-IPI-E, SL-550TR-IPI-E, SL-550TR-E, SL-950TR-IPI-E specifications

Hearth and Home Technologies is renowned for its innovative fireplace solutions, and their SL series of gas fireplaces exemplifies this commitment to quality and technology. The SL-950TR-E, SL-950TR-IPI-E, SL-550TR-E, SL-550TR-IPI-E, and SL-750TR-IPI-E models are designed to enhance the beauty and comfort of any living space while offering a range of advanced features.

The SL-950TR-E and SL-950TR-IPI-E are both large, linear models that provide a striking focal point for modern homes. With a glass front and sleek design, they can be installed in various settings, giving users flexibility in home design. The SL-950TR-E uses a traditional ignition system, while the SL-950TR-IPI-E incorporates an innovative intermittent pilot ignition (IPI) system that enhances energy efficiency. This technology reduces gas usage by activating the pilot light only when needed, contributing to lower utility bills.

The SL-550TR-E and SL-550TR-IPI-E models are slightly smaller but still deliver impressive heating performance. Similar to their larger counterparts, these models feature a contemporary design, perfect for homeowners who wish to blend warmth with modern aesthetics. The SL-550TR-E operates using a traditional ignition method, while the IPI variant also benefits from energy-efficient technology, ensuring that users can enjoy the ambiance of a fireplace without excessive energy consumption.

For those seeking a balance of size and efficiency, the SL-750TR-IPI-E stands out with its powerful output and sleek design. This model offers customizable flame and ember bed options, allowing users to create the ambiance they desire. The IPI system in the SL-750TR-IPI-E also enables users to control the fireplace with greater precision, providing convenience and comfort at the touch of a button.

All models feature advanced safety features, including glass safety barriers and an automated shut-off mechanism, ensuring peace of mind for homeowners. The easy-to-use remote controls offer additional convenience, allowing users to adjust flame intensity and heat output without leaving their seats.

In summary, the Hearth and Home Technologies SL series of gas fireplaces, including the SL-950TR-E, SL-950TR-IPI-E, SL-550TR-E, SL-550TR-IPI-E, and SL-750TR-IPI-E, combine aesthetic appeal with cutting-edge technology. With their modern designs, various size options, and efficient ignition systems, they provide homeowners with both warmth and elegance, making them a perfect choice for any contemporary living space.