Hearth and Home Technologies SL-950TR-IPI-E Top Vent Vertical Termination Venting with 3 elbows

Page 32

Top Vent - Vertical Termination

Venting with 3 elbows

V1 MIN.

SL-550TR-E

SL-750TR-E

SL-950TR-E

 

 

H MAX.

H MAX.

H MAX.

V2

V1 + V2 MIN.

 

 

90 Elbow

1/2 ft.

152 mm

1/2 ft.

152 mm

0 ft.

0 mm

*

*

 

 

 

 

 

 

 

 

 

 

1/2 ft.

152 mm

1 ft.

305 mm

1 ft.

305 mm

1 ft.

305 mm

*

*

 

 

 

 

 

 

 

 

 

 

1-1/2 ft.

457 mm

2 ft.

610 mm

2 ft.

610 mm

2 ft.

610 mm

*

*

 

 

 

 

 

 

 

 

 

 

2-1/2 ft.

762 mm

4 ft.

1.2 m

4 ft.

1.2 m

4 ft.

1.2 m

*

*

 

 

 

 

 

 

 

 

 

 

3-1/2 ft.

1.1 m

6 ft.

1.8 m

6 ft.

1.8 m

6 ft.

1.8 m

*

*

 

 

 

 

 

 

 

 

 

 

4-1/2 ft.

1.4 m

14 ft.

4.3 m

14 ft.

4.3 m

14 ft.

4.3 m

*

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H MAX. =14 ft. (4.6 m)

 

 

 

 

V1 + V2 + H1 + H2 MAX. = 40 ft. (12.2 m)

* No specific restrictions on this value EXCEPT V1 + V2 + H1 + H2 cannot exceed 40 ft. (12.2 m)

Note: Use SLP Series components only.

Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 7.3).

V2

H1

H2

V1

 

 

INSTALLED

 

HORIZONTALLY

Figure 7.10

32

Heat & Glo • SL-550 / 750 / 950TR-E2118-900 Rev. L • 11/08

Image 32
Contents What to do if you smell gas HOT SurfacesXxxxxxxx CongratulationsHomeowner Reference Information Table of Contents User GuideAppliance Setup TroubleshootingFinishing Reference MaterialsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty High Altitude Installations Listing and Code ApprovalsAppliance Certification Tempered Glass SpecificationsNon-Combustible Materials Specification Combustible Materials SpecificationElectrical Codes C22.1Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Heat & Glo SL-550 / 750 / 950TR-E 2118-900 Rev. L 11/08Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFan Kit optional Clear SpaceTo light the burner, flip the ON/OFF switch to Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASLighting Instructions Standing Pilot After Fireplace is Lit Frequently Asked QuestionsIssue Solutions Maintenance and Service Maintenance Tasks-HomeownerGlass Cleaning Remote ControlMaintenance Tasks-Qualified Service Technician Gasket Seal and Glass Assembly InspectionVenting LogsEither cobrahead or SIT Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Framing and Clearances Selecting Appliance LocationModels Constructing the Appliance ChaseClearances Mantel and Wall Projections Mantel Leg Acceptable on both sides of openingOpening Termination LocationsVent Termination Minimum Clearances = Area Where Terminal is not Permitted = Vent Terminal = AIR Supply InletVent Information and Diagrams Approved PipeVent Table Key Use of ElbowsUse of Flex Vent Minimum Maximum Top Vent Horizontal Termination Venting with 2 elbows MinimumVenting with 3 elbows V1 Minimum H1 + H2 MaximumTop Vent Vertical Termination No Elbows V1 = 60 ft. Max .3 m Exhaust restrictor InstructionsTop Vent Vertical Termination Venting with 2 elbows SL-550TR-E SL-750TR-E SL-950TR-ETop Vent Vertical Termination Venting with 3 elbows MIN SL-550TR-E SL-750TR-E SL-950TR-ETop Vent Vertical Termination Venting with 4 elbows V1 MIN H1 MAX V2 MIN H2 MAX V3 MINH1 = 9 in mm Maximum Rear Vent Horizontal Termination No ElbowsRear Vent Horizontal Termination One 45º Elbow Rear Vent Horizontal Termination Venting with 2 elbows Rear Vent Horizontal Termination Venting with 3 elbowsH1 + H2 MAX H2 + H3 MAX H1 + H2+ H3 MAX+ H 2 MAX MIN Rear Vent Vertical Termination Venting with 1 elbowRear Vent Vertical Termination Venting with 2 elbows Rear Vent Vertical Termination Venting with 3 elbows MIN MAX + H 2 MAXVent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Installing Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Appliance Preparation Top VentRear Vent Cut the metal retaining band and fold the sides outSecuring and Leveling the Appliance 13 Proper Positioning and Securing of an ApplianceInstalling Vent Pipe DVP and SLP Pipe Attach Vent to the Firebox AssemblyAssemble Vent Sections DVP Pipe Only Assemble Pipe SectionsAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Foot minimum in snow regions Install Metal Roof FlashingAssemble and Install Storm Collar Install RF4-8 18 Secure Pipe with SLP-FSHeat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Decorative Wall Components SLP only Refer to of this manual Install Horizontal Termination Cap DVP and SLP PipeAnsi Z223.1 and CAN/CGA-B149 installation codes Gas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Intellifire Ignition System WiringStanding Pilot Ignition System Wiring Optional Accessories RequirementsIntellifire Ignition Wiring Diagram with Remote Receiver Electrical Service and Repair Standing Pilot Ignition Wiring DiagramJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing Material Facing MaterialsTo install the Splatter Guard Splatter GuardTo Close the Lower Access Panel To Remove the Splatter GuardDoors Finishing Clearances for Aero, Chad and Halston FrontsElevated Hearth Systems Appliance Setup Install the Log Assembly SRV2115-701 SRV2118-701 SRV2121-701 Shutter Settings Install Trim and/or SurroundAir Shutter Setting Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Ues to spark, and main Inches Millimeters Appliance Dimension DiagramReference Materials Vent Components Diagrams P 4 5 4 5 E lb o wDVP-TRAP DVP vent componentsRF6M RF12M BEK DVP-BEK2COOL-ADD DVP-TRAPFLDVP-TVHW For use with IPI and DSI appliances onlyDVP-TB1 DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAPSLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAP Elbow Extended Heat ShieldRF4-8 Roof Flashing Ceiling FirestopAdapter Snorkel Black Support Box-BlackWall Thimble-Black Log Set Assembly Service PartsAt Depot Service Parts List SL-550TR-E, SL-550TR-IPI-EStocked SL-750TR-E, SL-750TR-IPI-E Service Parts List StockedSL-950TR-E, SL-950TR-IPI-E Service Parts List SL-950TR-E, SL-950TR-IPI-E GLA-950TRSL-550 / 750 / 950TR-IPI-E Description Serial # Part NumberStanding Pilot Valve Assembly Description Comments Part NumberContact Information

SL-750TR-E, SL-750TR-IPI-E, SL-550TR-IPI-E, SL-550TR-E, SL-950TR-IPI-E specifications

Hearth and Home Technologies is renowned for its innovative fireplace solutions, and their SL series of gas fireplaces exemplifies this commitment to quality and technology. The SL-950TR-E, SL-950TR-IPI-E, SL-550TR-E, SL-550TR-IPI-E, and SL-750TR-IPI-E models are designed to enhance the beauty and comfort of any living space while offering a range of advanced features.

The SL-950TR-E and SL-950TR-IPI-E are both large, linear models that provide a striking focal point for modern homes. With a glass front and sleek design, they can be installed in various settings, giving users flexibility in home design. The SL-950TR-E uses a traditional ignition system, while the SL-950TR-IPI-E incorporates an innovative intermittent pilot ignition (IPI) system that enhances energy efficiency. This technology reduces gas usage by activating the pilot light only when needed, contributing to lower utility bills.

The SL-550TR-E and SL-550TR-IPI-E models are slightly smaller but still deliver impressive heating performance. Similar to their larger counterparts, these models feature a contemporary design, perfect for homeowners who wish to blend warmth with modern aesthetics. The SL-550TR-E operates using a traditional ignition method, while the IPI variant also benefits from energy-efficient technology, ensuring that users can enjoy the ambiance of a fireplace without excessive energy consumption.

For those seeking a balance of size and efficiency, the SL-750TR-IPI-E stands out with its powerful output and sleek design. This model offers customizable flame and ember bed options, allowing users to create the ambiance they desire. The IPI system in the SL-750TR-IPI-E also enables users to control the fireplace with greater precision, providing convenience and comfort at the touch of a button.

All models feature advanced safety features, including glass safety barriers and an automated shut-off mechanism, ensuring peace of mind for homeowners. The easy-to-use remote controls offer additional convenience, allowing users to adjust flame intensity and heat output without leaving their seats.

In summary, the Hearth and Home Technologies SL series of gas fireplaces, including the SL-950TR-E, SL-950TR-IPI-E, SL-550TR-E, SL-550TR-IPI-E, and SL-750TR-IPI-E, combine aesthetic appeal with cutting-edge technology. With their modern designs, various size options, and efficient ignition systems, they provide homeowners with both warmth and elegance, making them a perfect choice for any contemporary living space.