Hearth and Home Technologies SL-750TR-IPI-E Install Decorative Ceiling Components SLP only

Page 47

F. Install Decorative Ceiling Components (SLP only)

A decorative ceiling thimble can be installed on a flat ceil- ing through which the vent passes. The decorative ceiling thimble is used to cover the firestop.

Seal the gap between the vent pipe and firestop using high temperature silicone to prevent cold air infiltration.

Install the decorative ceiling thimble by sliding it up to the ceiling and attaching it using the provided screws.

A decorative cathedral ceiling support box can be installed on a cathedral ceiling through which the vent passes.

Use a plumb-bob to mark the center line of the venting system on the ceiling and drill a small hole through the ceiling and roof at this point. Locate the hole and mark the outline of the cathedral ceiling support box on the outside roof.

Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box. Cut the hole 1/8 in. (3 mm) larger than the support box outline.

Lower the support box through the hole in the roof until its bottom is at least 2 in. (51 mm) below the ceiling (Figure 10.12).

Level the support box both vertically and horizontally and temporarily tack it in place through the inside walls into the roof sheathing.

Use tin snips to cut the support box from the top corners down to the roof line and fold the resulting flaps to the roof. See Figure 10.13.

Nail the flaps to the roof AFTER running a bead of non hardening sealant between the flaps and the roof.

WARNING! Risk of Fire! Clean out ALL materials from inside the support box and complete the vertical vent run and termination.

LEVEL

CATHEDRAL CEILING

SUPPORT BOX

2 in. (51 mm) MIN. BELOW FINISHED CEILING

CUT HOLE 1/8 in. (3 mm)

GREATER IN SIZE THAN

PATTERN OF SUPPORT

BOX AS IT IS PROJECTED

ONTO ROOF LINE

Figure 10.12

Figure 10.13

Heat & Glo • SL-550 / 750 / 950TR-E2118-900 Rev. L • 11/08

47

Image 47
Contents HOT Surfaces What to do if you smell gasXxxxxxxx CongratulationsHomeowner Reference Information User Guide Table of ContentsReference Materials Appliance SetupTroubleshooting FinishingCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Tempered Glass Specifications High Altitude InstallationsListing and Code Approvals Appliance CertificationC22.1 Non-Combustible Materials SpecificationCombustible Materials Specification Electrical CodesRequirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsHeat & Glo SL-550 / 750 / 950TR-E 2118-900 Rev. L 11/08 Gas Fireplace SafetyOperating Instructions User Guide Your FireplaceClear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalWhat to do if YOU Smell GAS To light the burner, flip the ON/OFF switch toLighting Instructions IPI Final inspection byLighting Instructions Standing Pilot After Fireplace is Lit Frequently Asked QuestionsIssue Solutions Remote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningLogs Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection VentingEither cobrahead or SIT Typical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Selecting Appliance Location Framing and ClearancesModels Constructing the Appliance ChaseClearances Mantel Leg Acceptable on both sides of opening Mantel and Wall ProjectionsOpening Termination LocationsVent Termination Minimum Clearances = Vent Terminal = AIR Supply Inlet = Area Where Terminal is not PermittedUse of Elbows Vent Information and DiagramsApproved Pipe Vent Table KeyUse of Flex Vent Minimum Maximum Minimum Top Vent Horizontal Termination Venting with 2 elbowsV1 Minimum H1 + H2 Maximum Venting with 3 elbowsExhaust restrictor Instructions Top Vent Vertical Termination No Elbows V1 = 60 ft. Max .3 mSL-550TR-E SL-750TR-E SL-950TR-E Top Vent Vertical Termination Venting with 2 elbowsMIN SL-550TR-E SL-750TR-E SL-950TR-E Top Vent Vertical Termination Venting with 3 elbowsV1 MIN H1 MAX V2 MIN H2 MAX V3 MIN Top Vent Vertical Termination Venting with 4 elbowsH1 = 9 in mm Maximum Rear Vent Horizontal Termination No ElbowsRear Vent Horizontal Termination One 45º Elbow H2 + H3 MAX H1 + H2+ H3 MAX Rear Vent Horizontal Termination Venting with 2 elbowsRear Vent Horizontal Termination Venting with 3 elbows H1 + H2 MAX+ H 2 MAX MIN Rear Vent Vertical Termination Venting with 1 elbowRear Vent Vertical Termination Venting with 2 elbows MIN MAX + H 2 MAX Rear Vent Vertical Termination Venting with 3 elbowsCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingInstalling Ceiling Firestop Install the Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Top Vent Appliance PreparationCut the metal retaining band and fold the sides out Rear Vent13 Proper Positioning and Securing of an Appliance Securing and Leveling the ApplianceAssemble Pipe Sections Installing Vent Pipe DVP and SLP PipeAttach Vent to the Firebox Assembly Assemble Vent Sections DVP Pipe OnlyAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Foot minimum in snow regions Install Metal Roof FlashingAssemble and Install Storm Collar 18 Secure Pipe with SLP-FS Install RF4-8Heat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Decorative Wall Components SLP only Refer to of this manual Install Horizontal Termination Cap DVP and SLP PipeAnsi Z223.1 and CAN/CGA-B149 installation codes Gas Connection Gas InformationFuel Conversion Gas PressureOptional Accessories Requirements Wiring RequirementsIntellifire Ignition System Wiring Standing Pilot Ignition System WiringIntellifire Ignition Wiring Diagram with Remote Receiver Standing Pilot Ignition Wiring Diagram Electrical Service and RepairWall Switch Installation for Fan Optional Junction Box InstallationFinishing Facing Materials Facing MaterialSplatter Guard To install the Splatter GuardTo Remove the Splatter Guard To Close the Lower Access PanelFinishing Clearances for Aero, Chad and Halston Fronts DoorsElevated Hearth Systems Appliance Setup Install the Log Assembly SRV2115-701 SRV2118-701 SRV2121-701 Shutter Settings Install Trim and/or SurroundAir Shutter Setting Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Ues to spark, and main Inches Millimeters Appliance Dimension DiagramReference Materials P 4 5 4 5 E lb o w Vent Components DiagramsDVP vent components DVP-TRAPDVP-TRAPFL RF6M RF12MBEK DVP-BEK2 COOL-ADDFor use with IPI and DSI appliances only DVP-TVHWDVP-TB1 DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAPSLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAP Roof Flashing Ceiling Firestop ElbowExtended Heat Shield RF4-8Adapter Snorkel Black Support Box-BlackWall Thimble-Black Service Parts Log Set AssemblyAt Depot Service Parts List SL-550TR-E, SL-550TR-IPI-EStocked SL-750TR-E, SL-750TR-IPI-E Stocked Service Parts ListSL-950TR-E, SL-950TR-IPI-E GLA-950TR Service Parts List SL-950TR-E, SL-950TR-IPI-EDescription Serial # Part Number SL-550 / 750 / 950TR-IPI-EDescription Comments Part Number Standing Pilot Valve AssemblyContact Information

SL-750TR-E, SL-750TR-IPI-E, SL-550TR-IPI-E, SL-550TR-E, SL-950TR-IPI-E specifications

Hearth and Home Technologies is renowned for its innovative fireplace solutions, and their SL series of gas fireplaces exemplifies this commitment to quality and technology. The SL-950TR-E, SL-950TR-IPI-E, SL-550TR-E, SL-550TR-IPI-E, and SL-750TR-IPI-E models are designed to enhance the beauty and comfort of any living space while offering a range of advanced features.

The SL-950TR-E and SL-950TR-IPI-E are both large, linear models that provide a striking focal point for modern homes. With a glass front and sleek design, they can be installed in various settings, giving users flexibility in home design. The SL-950TR-E uses a traditional ignition system, while the SL-950TR-IPI-E incorporates an innovative intermittent pilot ignition (IPI) system that enhances energy efficiency. This technology reduces gas usage by activating the pilot light only when needed, contributing to lower utility bills.

The SL-550TR-E and SL-550TR-IPI-E models are slightly smaller but still deliver impressive heating performance. Similar to their larger counterparts, these models feature a contemporary design, perfect for homeowners who wish to blend warmth with modern aesthetics. The SL-550TR-E operates using a traditional ignition method, while the IPI variant also benefits from energy-efficient technology, ensuring that users can enjoy the ambiance of a fireplace without excessive energy consumption.

For those seeking a balance of size and efficiency, the SL-750TR-IPI-E stands out with its powerful output and sleek design. This model offers customizable flame and ember bed options, allowing users to create the ambiance they desire. The IPI system in the SL-750TR-IPI-E also enables users to control the fireplace with greater precision, providing convenience and comfort at the touch of a button.

All models feature advanced safety features, including glass safety barriers and an automated shut-off mechanism, ensuring peace of mind for homeowners. The easy-to-use remote controls offer additional convenience, allowing users to adjust flame intensity and heat output without leaving their seats.

In summary, the Hearth and Home Technologies SL series of gas fireplaces, including the SL-950TR-E, SL-950TR-IPI-E, SL-550TR-E, SL-550TR-IPI-E, and SL-750TR-IPI-E, combine aesthetic appeal with cutting-edge technology. With their modern designs, various size options, and efficient ignition systems, they provide homeowners with both warmth and elegance, making them a perfect choice for any contemporary living space.