Hearth and Home Technologies SL-950TR-E, SL-750TR-E, SL-550TR-E = Vent Terminal = AIR Supply Inlet

Page 24

 

 

 

E

 

 

 

 

C

 

 

A

 

F

 

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

 

J

B

 

 

 

U.S

 

 

 

 

 

 

 

 

 

V

V

B

 

 

 

 

B

(3 FT.)

 

 

 

 

V

 

 

 

 

 

i

 

 

 

 

 

 

 

 

 

 

 

 

D

V

V

 

G

M

X

 

 

 

A

 

 

V

 

 

 

 

 

 

 

H or i

 

 

O

 

 

 

V

 

 

 

N

 

 

 

 

 

 

 

 

 

 

P

 

L

 

 

R

 

 

 

V

K

Electrical

K

V

 

 

 

 

Service

 

 

 

 

 

 

 

 

 

C

Q

V

(See Note 2)

Measure vertical clearances from this surface.

Measure horizontal clearances from this surface.

 

V

= VENT TERMINAL

X = AIR SUPPLY INLET

A

=

12 inches

clearances above grade, veranda,

 

 

 

(See Note 1)

porch, deck or balcony

B

=

12 inches

clearances to window or door

 

 

 

 

that may be opened, or to perma-

 

 

 

 

nently closed window. (Glass)

C

=

18 inches

vertical clearance to unventilated

 

 

 

 

soffit or to ventilated soffit located

 

 

 

 

above the terminal

 

 

 

30 inches

for vinyl clad soffits and below

 

 

 

 

electrical service

D

=

9 inches

clearance to outside corner

E

=

6 inches

clearance to inside corner

F

=

3 ft. (Canada)

not to be installed above a gas

 

 

 

 

meter/regulator assembly within 3

 

 

 

 

feet (90 cm) horizontally from the

 

 

 

 

center-line of the regulator

G

=

3 ft

clearance to gas service regulator

H

=

9 inches (U.S.A.)

vent outlet

 

 

 

 

12 inches (Canada) clearance to non-mechanical

 

 

 

(See Note 2)

air supply inlet to building or the

 

 

 

 

combustion air inlet to any other

i

=

3 ft. (U.S.A.)

appliance

 

 

 

 

6 ft. (Canada)

clearance to a mechanical (pow-

 

 

 

(See Note 2)

ered) air supply inlet

**a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

***only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor, or meets Note 2.

Note 1: On private property where termination is less than 7 feet above a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap shield is suggested. (See vents components page)

Note 2: Termination in a covered alcove space (spaces open only on one side and with an overhang) are permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be 3 feet minimum between termination caps. 2. All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap. 3. All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot below the termination cap.

Figure 6.4 Minimum Clearances for Termination

= AREA WHERE TERMINAL IS NOT PERMITTED

J**

=

7 ft

clearance above paved

 

 

(See Note 1)

sidewalk or a paved driveway

 

 

 

located on public property

K

=

6 inches

clearance from sides of electri-

 

 

(See Note 5)

cal service

L

=

12 inches

clearance above electrical

 

 

(See Note 5)

service

Covered Alcove Applications

M*** =

18 inches

clearance under veranda, porch,

 

 

 

 

deck, balcony or overhang

 

 

42 inches

......... vinyl

 

 

N

=

6 inches

non-vinyl sidewalls

 

 

12 inches

......... vinyl sidewalls

O

=

18 inches

......... non-vinyl soffit and overhang

 

 

42 inches

......... vinyl soffit and overhang

P

=

8 ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QMIN

RMAX

 

 

1 cap

 

3 feet

2 x Q ACTUAL

 

 

2 caps

 

6 feet

1 x Q ACTUAL

 

 

3 caps

 

9 feet

2/3 x Q ACTUAL

 

 

4 caps

 

12 feet

1/2 x Q ACTUAL

 

 

 

 

 

 

 

QMIN = # termination caps x 3 RMAX = (2 / # termination caps) x QACTUAL

Note 3: Local codes or regulations may require different clearances.

Note 4: Termination caps may be hot. Consider their proximity to doors or other traffic areas.

Note 5: Location of the vent termination must not interfere with access to the electrical service.

In the U.S and Canada: Vent system termination is NOT permitted in screened porches.

Vent system termination is permitted in porch areas with two or more sides open. You must follow all side walls, overhang and ground clearances as stated in the instructions.

Heat & Glo assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.

CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.

24

Heat & Glo • SL-550 / 750 / 950TR-E2118-900 Rev. L • 11/08

Image 24
Contents What to do if you smell gas HOT SurfacesCongratulations Homeowner Reference InformationXxxxxxxx Table of Contents User GuideAppliance Setup TroubleshootingFinishing Reference MaterialsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty High Altitude Installations Listing and Code ApprovalsAppliance Certification Tempered Glass SpecificationsNon-Combustible Materials Specification Combustible Materials SpecificationElectrical Codes C22.1Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Heat & Glo SL-550 / 750 / 950TR-E 2118-900 Rev. L 11/08Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFan Kit optional Clear SpaceTo light the burner, flip the ON/OFF switch to Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASLighting Instructions Standing Pilot Frequently Asked Questions Issue SolutionsAfter Fireplace is Lit Maintenance and Service Maintenance Tasks-HomeownerGlass Cleaning Remote ControlMaintenance Tasks-Qualified Service Technician Gasket Seal and Glass Assembly InspectionVenting LogsEither cobrahead or SIT Getting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesModels Mantel and Wall Projections Mantel Leg Acceptable on both sides of openingTermination Locations Vent Termination Minimum ClearancesOpening = Area Where Terminal is not Permitted = Vent Terminal = AIR Supply InletVent Information and Diagrams Approved PipeVent Table Key Use of ElbowsUse of Flex Vent Minimum Maximum Top Vent Horizontal Termination Venting with 2 elbows MinimumVenting with 3 elbows V1 Minimum H1 + H2 MaximumTop Vent Vertical Termination No Elbows V1 = 60 ft. Max .3 m Exhaust restrictor InstructionsTop Vent Vertical Termination Venting with 2 elbows SL-550TR-E SL-750TR-E SL-950TR-ETop Vent Vertical Termination Venting with 3 elbows MIN SL-550TR-E SL-750TR-E SL-950TR-ETop Vent Vertical Termination Venting with 4 elbows V1 MIN H1 MAX V2 MIN H2 MAX V3 MINRear Vent Horizontal Termination No Elbows Rear Vent Horizontal Termination One 45º ElbowH1 = 9 in mm Maximum Rear Vent Horizontal Termination Venting with 2 elbows Rear Vent Horizontal Termination Venting with 3 elbowsH1 + H2 MAX H2 + H3 MAX H1 + H2+ H3 MAXRear Vent Vertical Termination Venting with 1 elbow Rear Vent Vertical Termination Venting with 2 elbows+ H 2 MAX MIN Rear Vent Vertical Termination Venting with 3 elbows MIN MAX + H 2 MAXVent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Installing Ceiling FirestopInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Top VentRear Vent Cut the metal retaining band and fold the sides outSecuring and Leveling the Appliance 13 Proper Positioning and Securing of an ApplianceInstalling Vent Pipe DVP and SLP Pipe Attach Vent to the Firebox AssemblyAssemble Vent Sections DVP Pipe Only Assemble Pipe SectionsAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarFoot minimum in snow regions Install RF4-8 18 Secure Pipe with SLP-FSInstall Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap DVP and SLP Pipe Ansi Z223.1 and CAN/CGA-B149 installation codesRefer to of this manual Gas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Intellifire Ignition System WiringStanding Pilot Ignition System Wiring Optional Accessories RequirementsIntellifire Ignition Wiring Diagram with Remote Receiver Electrical Service and Repair Standing Pilot Ignition Wiring DiagramJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing Material Facing MaterialsTo install the Splatter Guard Splatter GuardTo Close the Lower Access Panel To Remove the Splatter GuardDoors Finishing Clearances for Aero, Chad and Halston FrontsElevated Hearth Systems Appliance Setup Install the Log Assembly SRV2115-701 SRV2118-701 SRV2121-701 Install Trim and/or Surround Air Shutter SettingShutter Settings Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Ues to spark, and main Appliance Dimension Diagram Reference MaterialsInches Millimeters Vent Components Diagrams P 4 5 4 5 E lb o wDVP-TRAP DVP vent componentsRF6M RF12M BEK DVP-BEK2COOL-ADD DVP-TRAPFLDVP-TVHW For use with IPI and DSI appliances onlyDVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP SLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAPDVP-TB1 Elbow Extended Heat ShieldRF4-8 Roof Flashing Ceiling FirestopSnorkel Black Support Box-Black Wall Thimble-BlackAdapter Log Set Assembly Service PartsService Parts List SL-550TR-E, SL-550TR-IPI-E StockedAt Depot SL-750TR-E, SL-750TR-IPI-E Service Parts List StockedSL-950TR-E, SL-950TR-IPI-E Service Parts List SL-950TR-E, SL-950TR-IPI-E GLA-950TRSL-550 / 750 / 950TR-IPI-E Description Serial # Part NumberStanding Pilot Valve Assembly Description Comments Part NumberContact Information

SL-750TR-E, SL-750TR-IPI-E, SL-550TR-IPI-E, SL-550TR-E, SL-950TR-IPI-E specifications

Hearth and Home Technologies is renowned for its innovative fireplace solutions, and their SL series of gas fireplaces exemplifies this commitment to quality and technology. The SL-950TR-E, SL-950TR-IPI-E, SL-550TR-E, SL-550TR-IPI-E, and SL-750TR-IPI-E models are designed to enhance the beauty and comfort of any living space while offering a range of advanced features.

The SL-950TR-E and SL-950TR-IPI-E are both large, linear models that provide a striking focal point for modern homes. With a glass front and sleek design, they can be installed in various settings, giving users flexibility in home design. The SL-950TR-E uses a traditional ignition system, while the SL-950TR-IPI-E incorporates an innovative intermittent pilot ignition (IPI) system that enhances energy efficiency. This technology reduces gas usage by activating the pilot light only when needed, contributing to lower utility bills.

The SL-550TR-E and SL-550TR-IPI-E models are slightly smaller but still deliver impressive heating performance. Similar to their larger counterparts, these models feature a contemporary design, perfect for homeowners who wish to blend warmth with modern aesthetics. The SL-550TR-E operates using a traditional ignition method, while the IPI variant also benefits from energy-efficient technology, ensuring that users can enjoy the ambiance of a fireplace without excessive energy consumption.

For those seeking a balance of size and efficiency, the SL-750TR-IPI-E stands out with its powerful output and sleek design. This model offers customizable flame and ember bed options, allowing users to create the ambiance they desire. The IPI system in the SL-750TR-IPI-E also enables users to control the fireplace with greater precision, providing convenience and comfort at the touch of a button.

All models feature advanced safety features, including glass safety barriers and an automated shut-off mechanism, ensuring peace of mind for homeowners. The easy-to-use remote controls offer additional convenience, allowing users to adjust flame intensity and heat output without leaving their seats.

In summary, the Hearth and Home Technologies SL series of gas fireplaces, including the SL-950TR-E, SL-950TR-IPI-E, SL-550TR-E, SL-550TR-IPI-E, and SL-750TR-IPI-E, combine aesthetic appeal with cutting-edge technology. With their modern designs, various size options, and efficient ignition systems, they provide homeowners with both warmth and elegance, making them a perfect choice for any contemporary living space.