Hearth and Home Technologies SL-550TR-IPI-E, SL-950TR-E, SL-750TR-E Install the Log Assembly

Page 64

F. Install the Log Assembly

If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately, refer to the following instructions.

Note: Figure 1 illustrates the recommended gap between the burner and the lava rock retainer.

Carefully remove the logs from the packaging. CAUTION: Logs are fragile!

Log Set Assembly: LOGS-550-E, 750-E, 950-E

Model: SL-550TR-E, 750TR-E, 950TR-E,

SL-550TV-E, SL-750TV-E, SL-950TV-E

3/8 in.

Burner

Lava Rock

retainer

No lava rock may be placed past this edge.

Figure 1

Indentation

1

Slot

Figure 2

Left rear log tab

Indentation

1

Mate slot with tab

Figure 4

Log #1: Locate the slot on the bottom right side of log 1. Mate the slot with the right rear log tab. Pull the left end of log #1 forward until it touches the left rear log tab.

Left rear log tabRight rear log tab

Shoulder screw

Lava Rock retainer

Grate tine (4)

Figure 3

Log # 2 should touch firebox

2

Figure 5

Mate notch with grate tine

 

Log #2: Mate the left grate tine with the notch located on the left end of log #2. The right end of log #2 should rest on log #1 as shown. Be sure that the top of log # 2 touches the back of the firebox.

2118-935D 6/07

64

Heat & Glo • SL-550 / 750 / 950TR-E2118-900 Rev. L • 11/08

Image 64
Contents What to do if you smell gas HOT SurfacesHomeowner Reference Information CongratulationsXxxxxxxx Table of Contents User GuideAppliance Setup TroubleshootingFinishing Reference MaterialsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty High Altitude Installations Listing and Code ApprovalsAppliance Certification Tempered Glass SpecificationsNon-Combustible Materials Specification Combustible Materials SpecificationElectrical Codes C22.1Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Heat & Glo SL-550 / 750 / 950TR-E 2118-900 Rev. L 11/08Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFan Kit optional Clear SpaceTo light the burner, flip the ON/OFF switch to Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASLighting Instructions Standing Pilot Issue Solutions Frequently Asked QuestionsAfter Fireplace is Lit Maintenance and Service Maintenance Tasks-HomeownerGlass Cleaning Remote ControlMaintenance Tasks-Qualified Service Technician Gasket Seal and Glass Assembly InspectionVenting LogsEither cobrahead or SIT Getting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Framing and Clearances Selecting Appliance LocationClearances Constructing the Appliance ChaseModels Mantel and Wall Projections Mantel Leg Acceptable on both sides of openingVent Termination Minimum Clearances Termination LocationsOpening = Area Where Terminal is not Permitted = Vent Terminal = AIR Supply InletVent Information and Diagrams Approved PipeVent Table Key Use of ElbowsUse of Flex Vent Minimum Maximum Top Vent Horizontal Termination Venting with 2 elbows MinimumVenting with 3 elbows V1 Minimum H1 + H2 MaximumTop Vent Vertical Termination No Elbows V1 = 60 ft. Max .3 m Exhaust restrictor InstructionsTop Vent Vertical Termination Venting with 2 elbows SL-550TR-E SL-750TR-E SL-950TR-ETop Vent Vertical Termination Venting with 3 elbows MIN SL-550TR-E SL-750TR-E SL-950TR-ETop Vent Vertical Termination Venting with 4 elbows V1 MIN H1 MAX V2 MIN H2 MAX V3 MINRear Vent Horizontal Termination One 45º Elbow Rear Vent Horizontal Termination No ElbowsH1 = 9 in mm Maximum Rear Vent Horizontal Termination Venting with 2 elbows Rear Vent Horizontal Termination Venting with 3 elbowsH1 + H2 MAX H2 + H3 MAX H1 + H2+ H3 MAXRear Vent Vertical Termination Venting with 2 elbows Rear Vent Vertical Termination Venting with 1 elbow+ H 2 MAX MIN Rear Vent Vertical Termination Venting with 3 elbows MIN MAX + H 2 MAXVent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Installing Ceiling FirestopFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Appliance Preparation Top VentRear Vent Cut the metal retaining band and fold the sides outSecuring and Leveling the Appliance 13 Proper Positioning and Securing of an ApplianceInstalling Vent Pipe DVP and SLP Pipe Attach Vent to the Firebox AssemblyAssemble Vent Sections DVP Pipe Only Assemble Pipe SectionsAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Assemble and Install Storm Collar Install Metal Roof FlashingFoot minimum in snow regions Install RF4-8 18 Secure Pipe with SLP-FSInstall Decorative Wall Components SLP only Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination Ansi Z223.1 and CAN/CGA-B149 installation codes Install Horizontal Termination Cap DVP and SLP PipeRefer to of this manual Gas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Intellifire Ignition System WiringStanding Pilot Ignition System Wiring Optional Accessories RequirementsIntellifire Ignition Wiring Diagram with Remote Receiver Electrical Service and Repair Standing Pilot Ignition Wiring DiagramJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing Material Facing MaterialsTo install the Splatter Guard Splatter GuardTo Close the Lower Access Panel To Remove the Splatter GuardDoors Finishing Clearances for Aero, Chad and Halston FrontsElevated Hearth Systems Appliance Setup Install the Log Assembly SRV2115-701 SRV2118-701 SRV2121-701 Air Shutter Setting Install Trim and/or SurroundShutter Settings Symptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Ues to spark, and main Reference Materials Appliance Dimension DiagramInches Millimeters Vent Components Diagrams P 4 5 4 5 E lb o wDVP-TRAP DVP vent componentsRF6M RF12M BEK DVP-BEK2COOL-ADD DVP-TRAPFLDVP-TVHW For use with IPI and DSI appliances onlySLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAP DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAPDVP-TB1 Elbow Extended Heat ShieldRF4-8 Roof Flashing Ceiling FirestopWall Thimble-Black Snorkel Black Support Box-BlackAdapter Log Set Assembly Service PartsStocked Service Parts List SL-550TR-E, SL-550TR-IPI-EAt Depot SL-750TR-E, SL-750TR-IPI-E Service Parts List StockedSL-950TR-E, SL-950TR-IPI-E Service Parts List SL-950TR-E, SL-950TR-IPI-E GLA-950TRSL-550 / 750 / 950TR-IPI-E Description Serial # Part NumberStanding Pilot Valve Assembly Description Comments Part NumberContact Information

SL-750TR-E, SL-750TR-IPI-E, SL-550TR-IPI-E, SL-550TR-E, SL-950TR-IPI-E specifications

Hearth and Home Technologies is renowned for its innovative fireplace solutions, and their SL series of gas fireplaces exemplifies this commitment to quality and technology. The SL-950TR-E, SL-950TR-IPI-E, SL-550TR-E, SL-550TR-IPI-E, and SL-750TR-IPI-E models are designed to enhance the beauty and comfort of any living space while offering a range of advanced features.

The SL-950TR-E and SL-950TR-IPI-E are both large, linear models that provide a striking focal point for modern homes. With a glass front and sleek design, they can be installed in various settings, giving users flexibility in home design. The SL-950TR-E uses a traditional ignition system, while the SL-950TR-IPI-E incorporates an innovative intermittent pilot ignition (IPI) system that enhances energy efficiency. This technology reduces gas usage by activating the pilot light only when needed, contributing to lower utility bills.

The SL-550TR-E and SL-550TR-IPI-E models are slightly smaller but still deliver impressive heating performance. Similar to their larger counterparts, these models feature a contemporary design, perfect for homeowners who wish to blend warmth with modern aesthetics. The SL-550TR-E operates using a traditional ignition method, while the IPI variant also benefits from energy-efficient technology, ensuring that users can enjoy the ambiance of a fireplace without excessive energy consumption.

For those seeking a balance of size and efficiency, the SL-750TR-IPI-E stands out with its powerful output and sleek design. This model offers customizable flame and ember bed options, allowing users to create the ambiance they desire. The IPI system in the SL-750TR-IPI-E also enables users to control the fireplace with greater precision, providing convenience and comfort at the touch of a button.

All models feature advanced safety features, including glass safety barriers and an automated shut-off mechanism, ensuring peace of mind for homeowners. The easy-to-use remote controls offer additional convenience, allowing users to adjust flame intensity and heat output without leaving their seats.

In summary, the Hearth and Home Technologies SL series of gas fireplaces, including the SL-950TR-E, SL-950TR-IPI-E, SL-550TR-E, SL-550TR-IPI-E, and SL-750TR-IPI-E, combine aesthetic appeal with cutting-edge technology. With their modern designs, various size options, and efficient ignition systems, they provide homeowners with both warmth and elegance, making them a perfect choice for any contemporary living space.