Hearth and Home Technologies SL-550TR-E, SL-950TR-E Assemble Vent Sections SLP Pipe Only

Page 45

B. Assemble Vent Sections (SLP Pipe Only)

To attach the first vent component to the starting collars of the appliance:

Attach an SLP-DVP24 adapter to the starting collar of the appliance.

Lock the vent components into place by sliding the pipe section onto the collar.

Align the seam of the pipe and seam of collar to allow engagement. Rotate the vent component to lock into place. Use this procedure for all vent components. See Figure 10.5.

Slide the gasket over the first vent section and place it flush to the appliance. This will prevent cold air infiltration. High temperature caulk may be used to hold the part in place.

Continue adding vent components, locking each succeeding component into place.

Ensure that each succeeding vent component is securely fitted and locked into the preceding component.

Commercial, Multi-family (Multi-level exceeding two sto- ries), or High-Rise Applications

For Installation into a commercial, multi-family (multi-level exceeding two stories) or high-rise applications: All outer pipe joints must be sealed with high temperature silicone, including the slip section that connects directly to the hori- zontal termination cap.

Apply a bead of silicone sealant inside the female outer pipe joint prior to joining sections. See Figure 10.1.

Only outer pipes need to be sealed. All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed in this manner, unless otherwise stated.

WARNING! Risk of Fire or Explosion! DO NOT break silicone seals on slip sections. Use care when remov- ing termination cap from slip pipe. If slip section seals are broken during removal of the termination cap, vent may leak.

Note: Align seams to engage pipe, then rotate counterclockwise to lock

Figure 10.5 Adding Venting Components

C. Assemble Slip Sections

Slide the inner flue of the slip section into the inner flue of the pipe section and the outer flue of the slip section over the outer flue of the pipe section. See Figure 10.6.

Slide together to the desired length.

Pilot hole

Figure 10.6 Slip Section Pilot Holes

Maintain a 1-1/2 in. (38 mm) overlap between the slip section and the pipe section.

Secure the pipe and slip section with two screws no longer than 1/2 in. (13 mm), using the pilot holes in the slip section. See Figure 10.7.

Figure 10.7 Screws into Slip Section

Continue adding pipe as necessary following instructions in “Assembling Pipe Sections.”

NOTICE: If slip section is too long, the inner and outer flues of the slip section can be cut to the desired length.

NOTICE: When installing a vent system with an HRC termination cap, all pipe system joints shall be sealed using a high temperature silicone sealant.

Apply a bead of silicone sealant inside the female outer pipe joint prior to joining sections.

Only outer pipes are sealed, sealing the inner flue is not required.

All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed.

Heat & Glo • SL-550 / 750 / 950TR-E2118-900 Rev. L • 11/08

45

Image 45
Contents HOT Surfaces What to do if you smell gasCongratulations Homeowner Reference InformationXxxxxxxx User Guide Table of ContentsTroubleshooting Appliance SetupFinishing Reference MaterialsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals High Altitude InstallationsAppliance Certification Tempered Glass SpecificationsCombustible Materials Specification Non-Combustible Materials SpecificationElectrical Codes C22.1Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsOperating Instructions User Guide Gas Fireplace SafetyYour Fireplace Heat & Glo SL-550 / 750 / 950TR-E 2118-900 Rev. L 11/08Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyFan Kit optional Clear SpaceLighting Instructions IPI To light the burner, flip the ON/OFF switch toFinal inspection by What to do if YOU Smell GASLighting Instructions Standing Pilot Frequently Asked Questions Issue SolutionsAfter Fireplace is Lit Maintenance Tasks-Homeowner Maintenance and ServiceGlass Cleaning Remote ControlGasket Seal and Glass Assembly Inspection Maintenance Tasks-Qualified Service TechnicianVenting LogsEither cobrahead or SIT Typical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Selecting Appliance Location Framing and ClearancesConstructing the Appliance Chase ClearancesModels Mantel Leg Acceptable on both sides of opening Mantel and Wall ProjectionsTermination Locations Vent Termination Minimum ClearancesOpening = Vent Terminal = AIR Supply Inlet = Area Where Terminal is not PermittedApproved Pipe Vent Information and DiagramsVent Table Key Use of ElbowsUse of Flex Vent Minimum Maximum Minimum Top Vent Horizontal Termination Venting with 2 elbowsV1 Minimum H1 + H2 Maximum Venting with 3 elbowsExhaust restrictor Instructions Top Vent Vertical Termination No Elbows V1 = 60 ft. Max .3 mSL-550TR-E SL-750TR-E SL-950TR-E Top Vent Vertical Termination Venting with 2 elbowsMIN SL-550TR-E SL-750TR-E SL-950TR-E Top Vent Vertical Termination Venting with 3 elbowsV1 MIN H1 MAX V2 MIN H2 MAX V3 MIN Top Vent Vertical Termination Venting with 4 elbowsRear Vent Horizontal Termination No Elbows Rear Vent Horizontal Termination One 45º ElbowH1 = 9 in mm Maximum Rear Vent Horizontal Termination Venting with 3 elbows Rear Vent Horizontal Termination Venting with 2 elbowsH1 + H2 MAX H2 + H3 MAX H1 + H2+ H3 MAXRear Vent Vertical Termination Venting with 1 elbow Rear Vent Vertical Termination Venting with 2 elbows+ H 2 MAX MIN MIN MAX + H 2 MAX Rear Vent Vertical Termination Venting with 3 elbowsPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationInstalling Ceiling Firestop Install the Ceiling FirestopInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Top Vent Appliance PreparationCut the metal retaining band and fold the sides out Rear Vent13 Proper Positioning and Securing of an Appliance Securing and Leveling the ApplianceAttach Vent to the Firebox Assembly Installing Vent Pipe DVP and SLP PipeAssemble Vent Sections DVP Pipe Only Assemble Pipe SectionsAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarFoot minimum in snow regions 18 Secure Pipe with SLP-FS Install RF4-8Install Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap DVP and SLP Pipe Ansi Z223.1 and CAN/CGA-B149 installation codesRefer to of this manual Fuel Conversion Gas InformationGas Pressure Gas ConnectionIntellifire Ignition System Wiring Wiring RequirementsStanding Pilot Ignition System Wiring Optional Accessories RequirementsIntellifire Ignition Wiring Diagram with Remote Receiver Standing Pilot Ignition Wiring Diagram Electrical Service and RepairWall Switch Installation for Fan Optional Junction Box InstallationFinishing Facing Materials Facing MaterialSplatter Guard To install the Splatter GuardTo Remove the Splatter Guard To Close the Lower Access PanelFinishing Clearances for Aero, Chad and Halston Fronts DoorsElevated Hearth Systems Appliance Setup Install the Log Assembly SRV2115-701 SRV2118-701 SRV2121-701 Install Trim and/or Surround Air Shutter SettingShutter Settings Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Ues to spark, and main Appliance Dimension Diagram Reference MaterialsInches Millimeters P 4 5 4 5 E lb o w Vent Components DiagramsDVP vent components DVP-TRAPBEK DVP-BEK2 RF6M RF12MCOOL-ADD DVP-TRAPFLFor use with IPI and DSI appliances only DVP-TVHWDVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP SLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAPDVP-TB1 Extended Heat Shield ElbowRF4-8 Roof Flashing Ceiling FirestopSnorkel Black Support Box-Black Wall Thimble-BlackAdapter Service Parts Log Set AssemblyService Parts List SL-550TR-E, SL-550TR-IPI-E StockedAt Depot SL-750TR-E, SL-750TR-IPI-E Stocked Service Parts ListSL-950TR-E, SL-950TR-IPI-E GLA-950TR Service Parts List SL-950TR-E, SL-950TR-IPI-EDescription Serial # Part Number SL-550 / 750 / 950TR-IPI-EDescription Comments Part Number Standing Pilot Valve AssemblyContact Information

SL-750TR-E, SL-750TR-IPI-E, SL-550TR-IPI-E, SL-550TR-E, SL-950TR-IPI-E specifications

Hearth and Home Technologies is renowned for its innovative fireplace solutions, and their SL series of gas fireplaces exemplifies this commitment to quality and technology. The SL-950TR-E, SL-950TR-IPI-E, SL-550TR-E, SL-550TR-IPI-E, and SL-750TR-IPI-E models are designed to enhance the beauty and comfort of any living space while offering a range of advanced features.

The SL-950TR-E and SL-950TR-IPI-E are both large, linear models that provide a striking focal point for modern homes. With a glass front and sleek design, they can be installed in various settings, giving users flexibility in home design. The SL-950TR-E uses a traditional ignition system, while the SL-950TR-IPI-E incorporates an innovative intermittent pilot ignition (IPI) system that enhances energy efficiency. This technology reduces gas usage by activating the pilot light only when needed, contributing to lower utility bills.

The SL-550TR-E and SL-550TR-IPI-E models are slightly smaller but still deliver impressive heating performance. Similar to their larger counterparts, these models feature a contemporary design, perfect for homeowners who wish to blend warmth with modern aesthetics. The SL-550TR-E operates using a traditional ignition method, while the IPI variant also benefits from energy-efficient technology, ensuring that users can enjoy the ambiance of a fireplace without excessive energy consumption.

For those seeking a balance of size and efficiency, the SL-750TR-IPI-E stands out with its powerful output and sleek design. This model offers customizable flame and ember bed options, allowing users to create the ambiance they desire. The IPI system in the SL-750TR-IPI-E also enables users to control the fireplace with greater precision, providing convenience and comfort at the touch of a button.

All models feature advanced safety features, including glass safety barriers and an automated shut-off mechanism, ensuring peace of mind for homeowners. The easy-to-use remote controls offer additional convenience, allowing users to adjust flame intensity and heat output without leaving their seats.

In summary, the Hearth and Home Technologies SL series of gas fireplaces, including the SL-950TR-E, SL-950TR-IPI-E, SL-550TR-E, SL-550TR-IPI-E, and SL-750TR-IPI-E, combine aesthetic appeal with cutting-edge technology. With their modern designs, various size options, and efficient ignition systems, they provide homeowners with both warmth and elegance, making them a perfect choice for any contemporary living space.