Hearth and Home Technologies SL-750TRS-IPI-E For Your Safety Read Before Lighting Instructions

Page 60

Standing Pilot Ignition

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

LIGHTING

INSTRUCTIONS

1.Turn off all electric power to the appliance.

2.Push in gas control knob slightly and turn clockwise to “OFF”.

A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explo- sion.

D. Do not use this appliance if any part has been under water. Im- mediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

NOTE: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do not force.

3.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the Safety Information located on the left side of this label. If you don’t smell gas, go to next step.

4.Find the pilot. The pilot is inside combustion chamber next to the main burner.

5.Turn knob on gas control counter clockwise

to “PILOT”.

6. Push in control knob all the way and hold in. Im-

mediately depress red or black piezo button. It may

require several depressions of the red or black

piezo button until PILOT lights. If PILOT light does

not light after 10 seconds, return to step 3. Continue to

WARNING: CAUTION:

hold the control knob in for about one minute after the

pilot is lit. Release knob and it will pop back out. Pilot

should remain lit. If it goes out, repeat steps 3 through 6.

DO NOT CONNECT 110 VAC TO THE CONTROL VALVE.

Improper installation, adjustment, al- teration, service or maintenance can cause injury or property damage. Re- fer to the owner’s information manual provided with this appliance.

This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

If not installed, operated, and main- tained in accordance with the man- ufacturer’s instructions, this product could expose you to substances in fuel or fuel combustion which are known to the State of California to cause can- cer, birth defects, or other reproduc- tive harm.

Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

Hot while in operation. Do not touch. Keep children, clothing, furniture, gaso- line and other liquids having flammable vapors away.

Do not operate the appliance with panel(s) removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified service person.

NOT FOR USE

WITH SOLID FUEL

For use with natural gas and propane. A conversion kit, as supplied by the manufacturer, shall be used to convert this appliance to the alternate fuel.

Also Certified for Installation in a Bedroom or a Bedsitting Room.

For assistance or additional informa- tion, consult a qualified installer, ser- vice agency or the gas supplier.

If knob does not pop up when released, stop and im-

 

mediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn

 

the gas control knob to “OFF” and call your service

 

technician or gas supplier.

7.

Turn gas control knob counterclockwise to

“ON”.

8.To light Burner, flip the on/off switch to the “ON” position, and close access grille.

9.Turn on all electric power to the appliance.

TO TURN OFF GAS TO APPLIANCE

1. Turn off all electric power to the appliance if service is to be performed.

2.

Open control access panel.

3.

Move switch to “OFF” position.

4.

Push in gas control knob slightly and turn clock-

 

wise

to OFF”. Do not force.

5.

 

Close control access panel.

 

 

464-903G

For additional information on operating your

Hearth & Home Technologies fireplace, please refer to www.fireplaces.com.

Final inspection by

60

Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI2120-900 Rev. D • 6/07

Image 60
Contents SL-750TRS-IPI-E SL-550TRS-IPI-E SL-350TRS-D SL-350TRS-IPI What to do if you smell gasHomeowner Reference Information Model Number Serial NumberTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsInstallation to ensure maximum safety and benefit Getting StartedTools and Supplies Needed Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesElevated Hearth Systems Mantel Projections All measurements are in inchesTermination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Alcove Applications Minimum Clearances for TerminationVent Information and Diagrams Vent Table KeyMeasuring Standards Use of ElbowsUse of Flex Vent FLEX-VENT ClearanceVent Diagrams Top Vent Horizontal Termination Venting One ElbowMinimum H1 Maximum Two Elbows Minimum MaximumTop Vent Horizontal Termination Three Elbows V1 Minimum H1 Maximum H1 + H2 MaximumTop Vent Vertical Termination No Elbow = 44 ft. Max .4 m Exhaust restrictor InstructionsTop Vent Vertical Termination Two 90º Elbows Minimum Maximum + V 2 MinimumTop Vent Vertical Termination Three 90º Elbows H2V1H1+ H2 Maximum V1 + V2 Minimum Top Vent Vertical Termination Four 90º Elbows V1 Min H1 Max V2 Min H2 Max V3 MinRear Vent Horizontal Termination No Elbow Two 90º Elbows H1 = 24 in mm MaximumH1 Maximum V1 Minimum H1 + H2 Maximum Rear Vent Horizontal Termination Three Elbows Rear Vent Vertical Termination One ElbowH1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Maximum V1 Minimum H1 MaximumRear Vent Vertical Termination Two Elbows H1+ H2 Maximum V1 MinimumH1 Maximum V1 Minimum H1 + H2 Vent Clearances and Framing Pipe Clearances to Combustibles Wall Penetration FramingCombustible Wall Penetration Non-Combustible Wall PenetrationInstalling the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Appliance Preparation Top VentRear Vent Cut the metal retaining band and fold the sides outSecuring and Leveling the Appliance Fire Risk Prevent contact with sagging, loose insulationInstalling Vent Pipe Assembly of Vent Sections DVP PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsDisassembly of Vent Sections DVP Pipe Securing the Vent Sections Vertical SectionsHorizontal Sections Installing the Horizontal Termination Cap Heat Shield Requirements for Horizontal TerminationAssembly of Vent Sections SL pipe Install Support BracketsAttach the First Vent Component to Starting Collars Continue Adding Vent ComponentsFire Risk. Explosion Risk Installing Roof Flashing and Vertical Ter- mination Cap Roof Pitch Min. FtAssembling and Installing Storm Collar 20 Assembling the Storm Collar Around the PipeGas Information Fuel Conversions Gas ConnectionGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Recommendation for Wire Connecting to the ApplianceElectrical Information Intellifire Ignition System Wiring Standing Pilot Ignition System WiringIntellifire Ignition Wiring Diagram with Remote Junction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing Material Facing MaterialTo install the Splatter Guard Splatter GuardTo Close the Lower Access Panel To Remove the Splatter GuardDoors SL-350TRS-D350-TemplateAppliance Setup Lava Rock, Mineral Wool/Ember PlacementClean the Appliance AccessoriesInstall Refractory Install logs according to the install manualStep SL-550TRS-IPI-E and SL-750TRS-IPI-E onlyModel SL-350TRS-D Log Set Assembly LOGS-350TRS-D Positioning the LogsPage Model SL-550TRS-IPI-E Log Set Assembly LOGS-SL550TRS-D Carefully remove the logs from the packagingStep Model SL-750TRS-IPI-E Log Set Assembly LOGS-SL750TRS- D Notch Glass Assembly Air Shutter SettingRemoving Glass Assembly Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceTurn off all electric power to the appliance On position. The ON/OFF switch mayLighting Appliance IPI Ignition Final inspection byFor Your Safety Read Before Lighting Instructions Standing Pilot IgnitionFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System flame has been lit, flame Maintaining and Servicing Appliance Maintenance Tasks Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP vent componentsMax EffectiveLength Horizontal Termination Cap787 mm 13-1/4 367 mm 24-5/8 625 mm 27-1/2 127 mm Roof Flashing Multi-pak 13-3/4 11-7/8 349 mm302 mm 13-3/4 13-7/8 352 mm 349 mmVerticalTermination Cap Highwind DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP Assembly Log Set Assembly Service PartsPart number list on following Service Parts List Standing Pilot Valve Assembly SL-350TRS-DIPI Valve Assembly To ensure correct service parts1412 Part number list on followingAdditional service part numbers may appear on following Pilot Orifice NG 593-528 Pilot Orifice LP 593-527 Regulator NGSL-750TRS-IPI-E SL-750TRS-IPI-E SL550TRS-IPI-E, SL-750TRS-IPI-E 582-840 Orifice LP #53C 582-583 Orifice NG #37CLimited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information

SL-550TRS-IPI-E, SL-350TRS-IPI, SL-750TRS-IPI-E, SL-350TRS-D specifications

Hearth and Home Technologies has made a significant impact in the hearth and home industry with its innovative line of gas fireplaces, specifically the SL-350TRS-D, SL-750TRS-IPI-E, SL-350TRS-IPI, and SL-550TRS-IPI-E models. Each of these units offers a unique combination of design and functionality, catering to diverse consumer needs.

The SL-350TRS-D is designed to create an inviting ambiance with its linear design and clean lines. It features a powerful remote control system, allowing users to adjust the flame height and heat output effortlessly. The advanced burner technology provides a realistic flame presentation that enhances the overall aesthetic of any space. Additionally, the direct vent system ensures optimal efficiency, channeling combustion gases outside while drawing in fresh air for combustion.

Moving on to the SL-750TRS-IPI-E, this model expands on the features of its predecessor, delivering higher heat output and an even larger viewing area. It includes an Integrated Piezo Ignition (IPI) system that ignites the fireplace at the push of a button, enhancing user convenience. The SL-750TRS-IPI-E also comes with adjustable flames and a selection of decorative media, allowing customers to customize the look to fit their home decor.

The SL-350TRS-IPI offers similar functionalities as the other models but incorporates additional energy-saving technologies. Its modulating gas valve allows for precise temperature control, reducing fuel consumption while maintaining comfortable warmth. Furthermore, this model is equipped with an intuitive smartphone application, providing users with remote access to control the fireplace from anywhere in the home.

Lastly, the SL-550TRS-IPI-E bridges the gap between the other units in terms of size and heat production. Like the SL-750, it features the IPI system for easy ignition and impressive design aesthetics. Its larger viewing area showcases a captivating flame display that serves as a focal point in any room. The fireplace also boasts heat management solutions, allowing for optimal warmth distribution without compromising on energy efficiency.

Overall, Hearth and Home Technologies' SL series offers advanced features and innovative technologies that cater to today’s energy-conscious consumers while creating an appealing environment. With their stylish designs, customizable options, and user-friendly functionalities, these models are set to elevate any home's ambiance. Whether you are looking for efficient heating or a modern design element, these gas fireplaces bring warmth, convenience, and style to the forefront.