Hearth and Home Technologies SL-750TRS-IPI-E, SL-350TRS-D, SL-550TRS-IPI-E Alcove Applications

Page 12

R

M

N

P

Q

(See Note 2)

V

T

VS Electrical S

Service

D*

V

V

V

= VENT TERMINAL

X = AIR SUPPLY INLET

= AREA WHERE TERMINAL IS NOT PERMITTED

A

=

12 inches

clearances above grade, veranda,

L**

=

.7 ft

clearance above paved

 

 

(See Note 1)

porch, deck or balcony

 

 

 

 

(See Note 1)

 

sidewalk or a paved driveway

B

=

12 inches

clearances to window or door

 

 

 

 

 

 

 

 

located on public property

M*** =

18 inches

clearance under veranda, porch,

 

 

 

that may be opened, or to perma-

 

 

 

nently closed window. (Glass)

 

 

 

 

 

 

 

 

deck, balcony or overhang

D*

=

18 inches

vertical clearance to unventilated

 

 

 

 

42 inches

vinyl

 

 

 

 

 

 

soffit or to ventilated soffit located

S

=

 

6 inches

clearance from sides of electri-

 

 

 

above the terminal

 

 

 

 

 

(See Note 5)

 

cal service

 

 

 

 

 

*30 inches

for vinyl clad soffits and below

T

=

12 inches

clearance above electrical

 

 

 

electrical service

 

 

 

 

(See Note 5)

 

service

 

 

 

F

=

9 inches

clearance to outside corner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alcove Applications

 

 

 

 

 

G

=

6 inches

clearance to inside corner

 

 

 

 

 

 

 

 

 

N

 

=

6 inches

non-vinyl sidewalls

 

H

=

3 ft. (Canada)

not to be installed above a gas

 

 

 

 

 

 

 

 

 

12 inches

vinyl sidewalls

 

 

 

 

meter/regulator assembly within 3

 

 

 

 

 

 

 

 

 

 

 

P

 

=

8 ft.

 

 

 

 

 

 

 

 

 

feet (90 cm) horizontally from the

 

 

 

 

 

 

 

 

 

 

 

 

center-line of the regulator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QMIN

 

RMAX

 

 

I

=

3 ft

clearance to gas service regulator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 cap

 

3 feet

 

2 x Q ACTUAL

 

 

 

 

 

vent outlet

 

 

 

 

 

 

 

 

J

=

9 inches (U.S.A.)

 

 

 

 

 

2 caps

 

6 feet

 

1 x Q ACTUAL

 

 

 

 

12 inches (Canada) clearance to non-mechanical

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 caps

 

9 feet

 

2/3 x Q ACTUAL

 

 

 

 

 

air supply inlet to building or the

 

 

 

 

 

 

 

 

 

 

 

combustion air inlet to any other

 

 

 

 

4 caps

 

12 feet

 

1/2 x Q ACTUAL

 

 

 

 

 

appliance

 

 

 

 

 

 

 

 

 

 

 

 

 

K

=

3 ft. (U.S.A.)

 

 

 

QMIN

= # termination caps x 3

RMAX = (2 / # termination caps) x QACTUAL

 

 

 

 

 

 

 

 

 

 

6 ft. (Canada)

clearance to a mechanical (pow-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ered) air supply inlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

**a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

***only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor, or meets Note 2.

NOTE 1: On private property where termination is less than 7 feet above a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap shield is suggested. (See vents components page)

NOTE 2: Termination in an alcove space (spaces open only on one side and with an overhang) are permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be 3 feet minimum between termination caps. 2. All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap. 3. All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot below the termination cap.

Figure 4.4 Minimum Clearances for Termination

NOTE 3: Local codes or regulations may require different clearances.

NOTE 4: Termination caps may be hot. Consider their proximity to doors or other traffic areas.

NOTE 5: Location of the vent termination must not interfere with access to the electrical service.

WARNING: In the U.S: Vent system termination is NOT permitted in screened porches. You must follow side wall, overhang and ground clearances as stated in the instructions.

In Canada: Vent system termination is NOT permitted in screened porches. Vent system termination is permitted in porch areas with two or more sides open. You must follow all side walls, overhang and ground clearances as stated in the instructions.

Heat & Glo assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.

CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.

12

Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI2120-900 Rev. D • 6/07

Image 12
Contents SL-750TRS-IPI-E SL-550TRS-IPI-E SL-350TRS-D SL-350TRS-IPI What to do if you smell gasHomeowner Reference Information Model Number Serial NumberTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsInstallation to ensure maximum safety and benefit Getting StartedTools and Supplies Needed Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesElevated Hearth Systems Mantel Projections All measurements are in inchesTermination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Alcove Applications Minimum Clearances for TerminationVent Information and Diagrams Vent Table KeyMeasuring Standards Use of ElbowsUse of Flex Vent FLEX-VENT ClearanceVent Diagrams Top Vent Horizontal Termination Venting One ElbowMinimum H1 Maximum Two Elbows Minimum MaximumTop Vent Horizontal Termination Three Elbows V1 Minimum H1 Maximum H1 + H2 MaximumTop Vent Vertical Termination No Elbow = 44 ft. Max .4 m Exhaust restrictor InstructionsTop Vent Vertical Termination Two 90º Elbows Minimum Maximum + V 2 MinimumTop Vent Vertical Termination Three 90º Elbows H2V1H1+ H2 Maximum V1 + V2 Minimum Top Vent Vertical Termination Four 90º Elbows V1 Min H1 Max V2 Min H2 Max V3 MinRear Vent Horizontal Termination No Elbow Two 90º Elbows H1 = 24 in mm MaximumH1 Maximum V1 Minimum H1 + H2 Maximum Rear Vent Horizontal Termination Three Elbows Rear Vent Vertical Termination One ElbowH1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Maximum V1 Minimum H1 MaximumRear Vent Vertical Termination Two Elbows H1+ H2 Maximum V1 MinimumH1 Maximum V1 Minimum H1 + H2 Vent Clearances and Framing Pipe Clearances to Combustibles Wall Penetration FramingCombustible Wall Penetration Non-Combustible Wall PenetrationInstalling the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Appliance Preparation Top VentRear Vent Cut the metal retaining band and fold the sides outSecuring and Leveling the Appliance Fire Risk Prevent contact with sagging, loose insulationInstalling Vent Pipe Assembly of Vent Sections DVP PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsDisassembly of Vent Sections DVP Pipe Securing the Vent Sections Vertical SectionsHorizontal Sections Installing the Horizontal Termination Cap Heat Shield Requirements for Horizontal TerminationAssembly of Vent Sections SL pipe Install Support BracketsAttach the First Vent Component to Starting Collars Continue Adding Vent ComponentsFire Risk. Explosion Risk Installing Roof Flashing and Vertical Ter- mination Cap Roof Pitch Min. FtAssembling and Installing Storm Collar 20 Assembling the Storm Collar Around the PipeGas Information Fuel Conversions Gas ConnectionGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Recommendation for Wire Connecting to the ApplianceElectrical Information Intellifire Ignition System Wiring Standing Pilot Ignition System WiringIntellifire Ignition Wiring Diagram with Remote Junction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing Material Facing MaterialTo install the Splatter Guard Splatter GuardTo Close the Lower Access Panel To Remove the Splatter GuardDoors SL-350TRS-D350-TemplateAppliance Setup Lava Rock, Mineral Wool/Ember PlacementClean the Appliance AccessoriesInstall Refractory Install logs according to the install manualStep SL-550TRS-IPI-E and SL-750TRS-IPI-E onlyModel SL-350TRS-D Log Set Assembly LOGS-350TRS-D Positioning the LogsPage Model SL-550TRS-IPI-E Log Set Assembly LOGS-SL550TRS-D Carefully remove the logs from the packagingStep Model SL-750TRS-IPI-E Log Set Assembly LOGS-SL750TRS- D Notch Glass Assembly Air Shutter SettingRemoving Glass Assembly Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceTurn off all electric power to the appliance On position. The ON/OFF switch mayLighting Appliance IPI Ignition Final inspection byFor Your Safety Read Before Lighting Instructions Standing Pilot IgnitionFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System flame has been lit, flame Maintaining and Servicing Appliance Maintenance Tasks Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP vent componentsMax EffectiveLength Horizontal Termination Cap787 mm 13-1/4 367 mm 24-5/8 625 mm 27-1/2 127 mm Roof Flashing Multi-pak 13-3/4 11-7/8 349 mm302 mm 13-3/4 13-7/8 352 mm 349 mmVerticalTermination Cap Highwind DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP Assembly Log Set Assembly Service PartsPart number list on following Service Parts List Standing Pilot Valve Assembly SL-350TRS-DIPI Valve Assembly To ensure correct service parts1412 Part number list on followingAdditional service part numbers may appear on following Pilot Orifice NG 593-528 Pilot Orifice LP 593-527 Regulator NGSL-750TRS-IPI-E SL-750TRS-IPI-E SL550TRS-IPI-E, SL-750TRS-IPI-E 582-840 Orifice LP #53C 582-583 Orifice NG #37CLimited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information

SL-550TRS-IPI-E, SL-350TRS-IPI, SL-750TRS-IPI-E, SL-350TRS-D specifications

Hearth and Home Technologies has made a significant impact in the hearth and home industry with its innovative line of gas fireplaces, specifically the SL-350TRS-D, SL-750TRS-IPI-E, SL-350TRS-IPI, and SL-550TRS-IPI-E models. Each of these units offers a unique combination of design and functionality, catering to diverse consumer needs.

The SL-350TRS-D is designed to create an inviting ambiance with its linear design and clean lines. It features a powerful remote control system, allowing users to adjust the flame height and heat output effortlessly. The advanced burner technology provides a realistic flame presentation that enhances the overall aesthetic of any space. Additionally, the direct vent system ensures optimal efficiency, channeling combustion gases outside while drawing in fresh air for combustion.

Moving on to the SL-750TRS-IPI-E, this model expands on the features of its predecessor, delivering higher heat output and an even larger viewing area. It includes an Integrated Piezo Ignition (IPI) system that ignites the fireplace at the push of a button, enhancing user convenience. The SL-750TRS-IPI-E also comes with adjustable flames and a selection of decorative media, allowing customers to customize the look to fit their home decor.

The SL-350TRS-IPI offers similar functionalities as the other models but incorporates additional energy-saving technologies. Its modulating gas valve allows for precise temperature control, reducing fuel consumption while maintaining comfortable warmth. Furthermore, this model is equipped with an intuitive smartphone application, providing users with remote access to control the fireplace from anywhere in the home.

Lastly, the SL-550TRS-IPI-E bridges the gap between the other units in terms of size and heat production. Like the SL-750, it features the IPI system for easy ignition and impressive design aesthetics. Its larger viewing area showcases a captivating flame display that serves as a focal point in any room. The fireplace also boasts heat management solutions, allowing for optimal warmth distribution without compromising on energy efficiency.

Overall, Hearth and Home Technologies' SL series offers advanced features and innovative technologies that cater to today’s energy-conscious consumers while creating an appealing environment. With their stylish designs, customizable options, and user-friendly functionalities, these models are set to elevate any home's ambiance. Whether you are looking for efficient heating or a modern design element, these gas fireplaces bring warmth, convenience, and style to the forefront.