Hearth and Home Technologies SL-550TRS-IPI-E, SL-750TRS-IPI-E Maintaining and Servicing Appliance

Page 66

15 Maintaining and Servicing Appliance

Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualified service technician should perform an appliance checkup at the beginning of each heating season.

WARNING

Risk of injury or property damage.

Before servicing:

Turn off gas.

Turn off electricity to appliance.

Disable remote control, if one is present.

Ensure appliance is completely cooled.

After servicing:

Replace any screen or barrier that was removed.

Reseal and reinstall any venting removed for servicing.

WARNING

Annual inspection by qualified technician recommended.

Check:

Condition of doors, surrounds and fronts.

Condition of glass, glass assembly and glass seal.

Obstructions of combustion and ventilation air.

Condition of logs.

Condition of firebox.

Burner ignition and operation.

Burner air shutter adjustment

Gas connections and fittings.

Obstructions of termination cap.

Clean:

• Glass

Air passageways, grilles, control compartment

Burner, burner ports

Risk of:

Fire

Delayed ignition or explosion

Exposure to combustion fumes

Odors

CAUTION

Handle glass assembly with care.

NOTE: Clean glass after initial 3-4 hours operation.

Longer operation without cleaning glass may cause a permanent white film on glass.

When cleaning glass door:

Avoid striking, scratching or slamming glass.

Do NOT use abrasive cleaners.

Use a hard water deposit glass cleaner on white film.

Do NOT clean glass when hot.

Turn off appliance after 3-4 hours of operation and

ALLOW TO COOL.

Remove and clean glass assembly.

Replace glass assembly and operate appliance for additional 12 hours.

Refer to maintenance instructions.

WARNING

Inspect external vent cap regularly.

Ensure no debris blocks cap.

Combustible materials blocking cap may ignite.

Restricted air flow affects burner operation.

66

Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI2120-900 Rev. D • 6/07

Image 66
Contents SL-750TRS-IPI-E SL-550TRS-IPI-E SL-350TRS-D SL-350TRS-IPI What to do if you smell gasHomeowner Reference Information Model Number Serial NumberTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsInstallation to ensure maximum safety and benefit Getting StartedTools and Supplies Needed Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesElevated Hearth Systems Mantel Projections All measurements are in inchesTermination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Alcove Applications Minimum Clearances for TerminationMeasuring Standards Vent Information and DiagramsVent Table Key Use of ElbowsUse of Flex Vent FLEX-VENT ClearanceVent Diagrams Top Vent Horizontal Termination Venting One ElbowMinimum H1 Maximum Two Elbows Minimum MaximumTop Vent Horizontal Termination Three Elbows V1 Minimum H1 Maximum H1 + H2 MaximumTop Vent Vertical Termination No Elbow = 44 ft. Max .4 m Exhaust restrictor InstructionsTop Vent Vertical Termination Two 90º Elbows Minimum Maximum + V 2 MinimumTop Vent Vertical Termination Three 90º Elbows H2V1H1+ H2 Maximum V1 + V2 Minimum Top Vent Vertical Termination Four 90º Elbows V1 Min H1 Max V2 Min H2 Max V3 MinRear Vent Horizontal Termination No Elbow Two 90º Elbows H1 = 24 in mm MaximumH1 Maximum V1 Minimum H1 + H2 Maximum H1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Maximum Rear Vent Horizontal Termination Three ElbowsRear Vent Vertical Termination One Elbow V1 Minimum H1 MaximumRear Vent Vertical Termination Two Elbows H1+ H2 Maximum V1 MinimumH1 Maximum V1 Minimum H1 + H2 Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration Framing Non-Combustible Wall PenetrationInstalling the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Appliance Preparation Top VentRear Vent Cut the metal retaining band and fold the sides outSecuring and Leveling the Appliance Fire Risk Prevent contact with sagging, loose insulationAttaching Vent to the Firebox Assembly Installing Vent PipeAssembly of Vent Sections DVP Pipe Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsDisassembly of Vent Sections DVP Pipe Securing the Vent Sections Vertical SectionsHorizontal Sections Installing the Horizontal Termination Cap Heat Shield Requirements for Horizontal TerminationAttach the First Vent Component to Starting Collars Assembly of Vent Sections SL pipeInstall Support Brackets Continue Adding Vent ComponentsFire Risk. Explosion Risk Installing Roof Flashing and Vertical Ter- mination Cap Roof Pitch Min. FtAssembling and Installing Storm Collar 20 Assembling the Storm Collar Around the PipeGas Pressures Gas InformationFuel Conversions Gas Connection Pressure Natural Gas PropaneHigh Altitude Installations Recommendation for Wire Connecting to the ApplianceElectrical Information Intellifire Ignition System Wiring Standing Pilot Ignition System WiringIntellifire Ignition Wiring Diagram with Remote Junction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing Material Facing MaterialTo install the Splatter Guard Splatter GuardTo Close the Lower Access Panel To Remove the Splatter GuardDoors SL-350TRS-D350-TemplateClean the Appliance Appliance SetupLava Rock, Mineral Wool/Ember Placement AccessoriesStep Install RefractoryInstall logs according to the install manual SL-550TRS-IPI-E and SL-750TRS-IPI-E onlyModel SL-350TRS-D Log Set Assembly LOGS-350TRS-D Positioning the LogsPage Model SL-550TRS-IPI-E Log Set Assembly LOGS-SL550TRS-D Carefully remove the logs from the packagingStep Model SL-750TRS-IPI-E Log Set Assembly LOGS-SL750TRS- D Notch Removing Glass Assembly Glass AssemblyAir Shutter Setting Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceLighting Appliance IPI Ignition Turn off all electric power to the applianceOn position. The ON/OFF switch may Final inspection byFor Your Safety Read Before Lighting Instructions Standing Pilot IgnitionFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System flame has been lit, flame Maintaining and Servicing Appliance Maintenance Tasks Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP vent componentsLength MaxEffective Horizontal Termination Cap302 mm 787 mm 13-1/4 367 mm 24-5/8 625 mm 27-1/2 127 mmRoof Flashing Multi-pak 13-3/4 11-7/8 349 mm 13-3/4 13-7/8 352 mm 349 mmVerticalTermination Cap Highwind DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP Assembly Log Set Assembly Service PartsPart number list on following Service Parts List Standing Pilot Valve Assembly SL-350TRS-DIPI Valve Assembly To ensure correct service parts1412 Part number list on followingAdditional service part numbers may appear on following Pilot Orifice NG 593-528 Pilot Orifice LP 593-527 Regulator NGSL-750TRS-IPI-E SL-750TRS-IPI-E SL550TRS-IPI-E, SL-750TRS-IPI-E 582-840 Orifice LP #53C 582-583 Orifice NG #37CLimited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information

SL-550TRS-IPI-E, SL-350TRS-IPI, SL-750TRS-IPI-E, SL-350TRS-D specifications

Hearth and Home Technologies has made a significant impact in the hearth and home industry with its innovative line of gas fireplaces, specifically the SL-350TRS-D, SL-750TRS-IPI-E, SL-350TRS-IPI, and SL-550TRS-IPI-E models. Each of these units offers a unique combination of design and functionality, catering to diverse consumer needs.

The SL-350TRS-D is designed to create an inviting ambiance with its linear design and clean lines. It features a powerful remote control system, allowing users to adjust the flame height and heat output effortlessly. The advanced burner technology provides a realistic flame presentation that enhances the overall aesthetic of any space. Additionally, the direct vent system ensures optimal efficiency, channeling combustion gases outside while drawing in fresh air for combustion.

Moving on to the SL-750TRS-IPI-E, this model expands on the features of its predecessor, delivering higher heat output and an even larger viewing area. It includes an Integrated Piezo Ignition (IPI) system that ignites the fireplace at the push of a button, enhancing user convenience. The SL-750TRS-IPI-E also comes with adjustable flames and a selection of decorative media, allowing customers to customize the look to fit their home decor.

The SL-350TRS-IPI offers similar functionalities as the other models but incorporates additional energy-saving technologies. Its modulating gas valve allows for precise temperature control, reducing fuel consumption while maintaining comfortable warmth. Furthermore, this model is equipped with an intuitive smartphone application, providing users with remote access to control the fireplace from anywhere in the home.

Lastly, the SL-550TRS-IPI-E bridges the gap between the other units in terms of size and heat production. Like the SL-750, it features the IPI system for easy ignition and impressive design aesthetics. Its larger viewing area showcases a captivating flame display that serves as a focal point in any room. The fireplace also boasts heat management solutions, allowing for optimal warmth distribution without compromising on energy efficiency.

Overall, Hearth and Home Technologies' SL series offers advanced features and innovative technologies that cater to today’s energy-conscious consumers while creating an appealing environment. With their stylish designs, customizable options, and user-friendly functionalities, these models are set to elevate any home's ambiance. Whether you are looking for efficient heating or a modern design element, these gas fireplaces bring warmth, convenience, and style to the forefront.