Hearth and Home Technologies SL-750TRS-IPI-E Constructing the Appliance Chase, Clearances

Page 8

B. Constructing the Appliance Chase

A chase is a vertical boxlike structure built to enclose the gas appliance and/or its vent system. Vertical vents that run on the outside of a building may be, but are not re- quired to be, installed inside a chase.

Construction of the chase may vary with the type of build- ing. These instructions are not substitutes for the require- ments of local building codes. Local building codes MUST be checked.

Chases should be constructed in the manner of all out- side walls of the home to prevent cold air drafting prob- lems. The chase should not break the outside building envelope in any manner.

Walls, ceiling, base plate and cantilever floor of the chase should be insulated. Vapor and air infiltration barriers should be installed in the chase as per regional codes for the rest of the home. Additionally, in regions where cold air infiltration may be an issue, the inside surfaces may be sheetrocked and taped for maximum air tightness.

To further prevent drafts, the wall shield and ceiling firestops should be caulked with high temperature caulk to seal gaps. Gas line holes and other openings should be caulked with high temp caulk or stuffed with unfaced

insulation. If the appliance is being installed on a cement slab, a layer of plywood may be placed underneath to pre- vent conducting cold up into the room.

C. Clearances

WARNING

Fire Risk.

Odor Risk.

Install appliance on hard metal or wood surfaces extending full width and depth of appliance.

Do NOT install appliance directly on carpeting, vinyl, tile or any combustible material other than wood.

WARNING

Fire Risk.

Construct chase to all clearance specifications in manual.

Locate and install appliance to all clearance

specifications in manual.

A

MEASURE FROM

 

TOP OF UNIT OPENING

 

OR FROM TOP OF HOOD

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

J

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

B

C

 

D

E

F

G

H

I

J

 

Models

DVP PIPE

SL PIPE

Rough

*DVP PIPE

SL PIPE

Rough

Clearance

 

 

 

 

 

 

Rough

Rough

Rough

Rough

Combustible

Combustible

Behind

Sides of

Front of

 

 

Opening

Opening

to Ceiling

Floor

Flooring

Appliance

Appliance

Appliance

 

 

Opening

Opening

(Height)

Opening

Opening

(Width)

 

 

 

 

 

 

 

 

 

 

 

(Width)

(Width)

 

(Depth)

(Depth)

 

 

 

 

 

 

 

 

Inches

10

8-5/8

38-1/4

28-1/4

16-1/4

42

32

0

0

1/2

1/2

36

 

SL-750TRS-IPI-E

254

219

971

699

413

1067

813

0

0

13

13

915

 

Millimeters

 

Inches

10

8-5/8

34-3/4

28-1/4

16-1/4

37

32

0

0

1/2

1/2

36

 

SL-550TRS-IPI-E

254

219

882

699

413

940

813

0

0

13

13

915

 

Millimeters

 

Inches

10

8-5/8

32-3/4

28-1/4

16-1/4

34

32

0

0

1/2

1/2

36

 

SL-350TRS-D

254

219

832

699

413

864

813

0

0

13

13

915

 

Millimeters

 

* Dimension when rear venting with one 90º elbow

 

 

 

 

 

 

 

 

 

 

 

Figure 3.2 Clearances to Combustibles

 

 

 

 

 

 

 

 

 

 

 

8

Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI2120-900 Rev. D • 6/07

 

 

Image 8
Contents SL-750TRS-IPI-E SL-550TRS-IPI-E SL-350TRS-D SL-350TRS-IPI What to do if you smell gasHomeowner Reference Information Model Number Serial NumberTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsTools and Supplies Needed Installation to ensure maximum safety and benefitGetting Started Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesElevated Hearth Systems Mantel Projections All measurements are in inchesSee .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Alcove Applications Minimum Clearances for TerminationVent Information and Diagrams Vent Table KeyMeasuring Standards Use of ElbowsUse of Flex Vent FLEX-VENT ClearanceMinimum H1 Maximum Vent DiagramsTop Vent Horizontal Termination Venting One Elbow Two Elbows Minimum MaximumTop Vent Horizontal Termination Three Elbows V1 Minimum H1 Maximum H1 + H2 MaximumTop Vent Vertical Termination No Elbow = 44 ft. Max .4 m Exhaust restrictor InstructionsTop Vent Vertical Termination Two 90º Elbows Minimum Maximum + V 2 MinimumH1+ H2 Maximum V1 + V2 Minimum Top Vent Vertical Termination Three 90º ElbowsH2V1 Top Vent Vertical Termination Four 90º Elbows V1 Min H1 Max V2 Min H2 Max V3 MinH1 Maximum V1 Minimum H1 + H2 Maximum Rear Vent Horizontal Termination No Elbow Two 90º ElbowsH1 = 24 in mm Maximum Rear Vent Horizontal Termination Three Elbows Rear Vent Vertical Termination One ElbowH1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Maximum V1 Minimum H1 MaximumH1 Maximum V1 Minimum H1 + H2 Rear Vent Vertical Termination Two ElbowsH1+ H2 Maximum V1 Minimum Vent Clearances and Framing Pipe Clearances to Combustibles Wall Penetration FramingCombustible Wall Penetration Non-Combustible Wall PenetrationVertical Penetration Framing Installing the Ceiling FirestopInstalling Attic Shield Appliance Preparation Top VentRear Vent Cut the metal retaining band and fold the sides outSecuring and Leveling the Appliance Fire Risk Prevent contact with sagging, loose insulationInstalling Vent Pipe Assembly of Vent Sections DVP PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsHorizontal Sections Disassembly of Vent Sections DVP PipeSecuring the Vent Sections Vertical Sections Installing the Horizontal Termination Cap Heat Shield Requirements for Horizontal TerminationAssembly of Vent Sections SL pipe Install Support BracketsAttach the First Vent Component to Starting Collars Continue Adding Vent ComponentsFire Risk. Explosion Risk Installing Roof Flashing and Vertical Ter- mination Cap Roof Pitch Min. FtAssembling and Installing Storm Collar 20 Assembling the Storm Collar Around the PipeGas Information Fuel Conversions Gas ConnectionGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Electrical Information Recommendation for WireConnecting to the Appliance Intellifire Ignition System Wiring Standing Pilot Ignition System WiringIntellifire Ignition Wiring Diagram with Remote Junction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing Material Facing MaterialTo install the Splatter Guard Splatter GuardTo Close the Lower Access Panel To Remove the Splatter GuardDoors SL-350TRS-D350-TemplateAppliance Setup Lava Rock, Mineral Wool/Ember PlacementClean the Appliance AccessoriesInstall Refractory Install logs according to the install manualStep SL-550TRS-IPI-E and SL-750TRS-IPI-E onlyModel SL-350TRS-D Log Set Assembly LOGS-350TRS-D Positioning the LogsPage Model SL-550TRS-IPI-E Log Set Assembly LOGS-SL550TRS-D Carefully remove the logs from the packagingStep Model SL-750TRS-IPI-E Log Set Assembly LOGS-SL750TRS- D Notch Glass Assembly Air Shutter SettingRemoving Glass Assembly Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceTurn off all electric power to the appliance On position. The ON/OFF switch mayLighting Appliance IPI Ignition Final inspection byFor Your Safety Read Before Lighting Instructions Standing Pilot IgnitionAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System flame has been lit, flame Maintaining and Servicing Appliance Maintenance Tasks Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP vent componentsMax EffectiveLength Horizontal Termination Cap787 mm 13-1/4 367 mm 24-5/8 625 mm 27-1/2 127 mm Roof Flashing Multi-pak 13-3/4 11-7/8 349 mm302 mm 13-3/4 13-7/8 352 mm 349 mmVerticalTermination Cap Highwind DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP Assembly Part number list on following Log Set AssemblyService Parts Service Parts List Standing Pilot Valve Assembly SL-350TRS-DIPI Valve Assembly To ensure correct service parts1412 Part number list on followingAdditional service part numbers may appear on following Pilot Orifice NG 593-528 Pilot Orifice LP 593-527 Regulator NGSL-750TRS-IPI-E SL-750TRS-IPI-E SL550TRS-IPI-E, SL-750TRS-IPI-E 582-840 Orifice LP #53C 582-583 Orifice NG #37CLimited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information

SL-550TRS-IPI-E, SL-350TRS-IPI, SL-750TRS-IPI-E, SL-350TRS-D specifications

Hearth and Home Technologies has made a significant impact in the hearth and home industry with its innovative line of gas fireplaces, specifically the SL-350TRS-D, SL-750TRS-IPI-E, SL-350TRS-IPI, and SL-550TRS-IPI-E models. Each of these units offers a unique combination of design and functionality, catering to diverse consumer needs.

The SL-350TRS-D is designed to create an inviting ambiance with its linear design and clean lines. It features a powerful remote control system, allowing users to adjust the flame height and heat output effortlessly. The advanced burner technology provides a realistic flame presentation that enhances the overall aesthetic of any space. Additionally, the direct vent system ensures optimal efficiency, channeling combustion gases outside while drawing in fresh air for combustion.

Moving on to the SL-750TRS-IPI-E, this model expands on the features of its predecessor, delivering higher heat output and an even larger viewing area. It includes an Integrated Piezo Ignition (IPI) system that ignites the fireplace at the push of a button, enhancing user convenience. The SL-750TRS-IPI-E also comes with adjustable flames and a selection of decorative media, allowing customers to customize the look to fit their home decor.

The SL-350TRS-IPI offers similar functionalities as the other models but incorporates additional energy-saving technologies. Its modulating gas valve allows for precise temperature control, reducing fuel consumption while maintaining comfortable warmth. Furthermore, this model is equipped with an intuitive smartphone application, providing users with remote access to control the fireplace from anywhere in the home.

Lastly, the SL-550TRS-IPI-E bridges the gap between the other units in terms of size and heat production. Like the SL-750, it features the IPI system for easy ignition and impressive design aesthetics. Its larger viewing area showcases a captivating flame display that serves as a focal point in any room. The fireplace also boasts heat management solutions, allowing for optimal warmth distribution without compromising on energy efficiency.

Overall, Hearth and Home Technologies' SL series offers advanced features and innovative technologies that cater to today’s energy-conscious consumers while creating an appealing environment. With their stylish designs, customizable options, and user-friendly functionalities, these models are set to elevate any home's ambiance. Whether you are looking for efficient heating or a modern design element, these gas fireplaces bring warmth, convenience, and style to the forefront.