C. After Appliance is Lit

Initial Break-in Procedure

When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn on high followed by a second burn up to 12 hours to fully drive off any odor from paint and lubricants used in the manufacturing process. Condensation of the glass is normal.

NOTE: The appliance should be run three to four hours on the initial start-up. Turn it off and let it cool completely. Remove and clean the glass. Replace the glass and run the appliance for an additional 12 hours. This will help to cure the products used in the paint and logs.

During this break-in period it is recommended that some windows in the house be opened for air circulation. This will help avoid setting off smoke detectors, and help eliminate any odors associated with the appliance’s initial burning.

WARNING

Fire Risk.

High Temperatures.

Keep combustible household items away from appliance.

Do NOT obstruct combustion and ventilation air.

Do NOT place combustible items on top of or in front of appliance.

Keep furniture, draperies away from appliance.

CAUTION

Prevent accidental appliance operation when not attended.

Unplug or remove batteries from remote control if absent or if appliance will not be used for an extended period of time.

Property damage possible from elevated temperatures.

CAUTION

Smoke and odors released during initial operation.

Open windows for air circulation.

Leave room during initial operation.

Smoke may set off smoke detectors.

Smoke and odors may be irritating to sensitive individuals.

WARNING

Fire Hazard.

Keep combustible materials, gasoline and other flammable vapors and liquids clear of appliance.

Do NOT store flammable materials in the appliance’s vicinity.

• Do NOT use gasoline, lantern fuel, kerosene, charcoal lighter fluid or similar liquids in this appliance.

• Combustible materials may ignite.

D. Frequently Asked Questions

ISSUE

SOLUTIONS

 

 

Condensation on the glass

This is a result of gas combustion and temperature variations. As the appliance warms, this

condensation will disappear.

 

 

 

Blue flames

This is a result of normal operation and the flames will begin to yellow as the appliance is al-

lowed to burn for 20 to 40 minutes.

 

 

 

 

When first operated, this appliance may release an odor for the first several hours. This is

Odor from appliance

caused by the curing of the paint and the burning off of any oils remaining from manufactur-

ing. Odor may also be released from finishing materials and adhesives used around the

 

 

appliance.

 

 

 

This is a normal result of the curing process of the paint and logs. Glass should be cleaned

Film on the glass

within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing

 

process. A non-abrasive cleaner such as gas fireplace glass cleaner may be necessary. See

 

your dealer.

 

 

 

Noise is caused by metal expanding and contracting as it heats up and cools down, similar to

Metallic noise

the sound produced by a furnace or heating duct. This noise does not affect the operation or

 

longevity of the appliance.

 

 

Is it normal to see the pilot flame burn

In an Intellifire ignition system it is normal to see the pilot flame, but it should turn off when

continually?

ON/OFF is turned off. In a standing pilot system the pilot will always stay on.

 

 

Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI2120-900 Rev. D • 6/07

61

Image 61
Contents What to do if you smell gas SL-750TRS-IPI-E SL-550TRS-IPI-E SL-350TRS-D SL-350TRS-IPIModel Number Serial Number Homeowner Reference InformationTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGetting Started Installation to ensure maximum safety and benefitTools and Supplies Needed Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseElevated Hearth Systems All measurements are in inches Mantel ProjectionsVent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Minimum Clearances for Termination Alcove ApplicationsVent Table Key Vent Information and DiagramsMeasuring Standards Use of ElbowsFLEX-VENT Clearance Use of Flex VentTop Vent Horizontal Termination Venting One Elbow Vent DiagramsMinimum H1 Maximum Minimum Maximum Two ElbowsV1 Minimum H1 Maximum H1 + H2 Maximum Top Vent Horizontal Termination Three ElbowsExhaust restrictor Instructions Top Vent Vertical Termination No Elbow = 44 ft. Max .4 mMinimum Maximum + V 2 Minimum Top Vent Vertical Termination Two 90º ElbowsH2V1 Top Vent Vertical Termination Three 90º ElbowsH1+ H2 Maximum V1 + V2 Minimum V1 Min H1 Max V2 Min H2 Max V3 Min Top Vent Vertical Termination Four 90º ElbowsH1 = 24 in mm Maximum Rear Vent Horizontal Termination No Elbow Two 90º ElbowsH1 Maximum V1 Minimum H1 + H2 Maximum Rear Vent Vertical Termination One Elbow Rear Vent Horizontal Termination Three ElbowsH1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Maximum V1 Minimum H1 MaximumH1+ H2 Maximum V1 Minimum Rear Vent Vertical Termination Two ElbowsH1 Maximum V1 Minimum H1 + H2 Pipe Clearances to Combustibles Wall Penetration Framing Vent Clearances and FramingCombustible Wall Penetration Non-Combustible Wall PenetrationInstalling Attic Shield Installing the Ceiling FirestopVertical Penetration Framing Top Vent Appliance PreparationCut the metal retaining band and fold the sides out Rear VentFire Risk Prevent contact with sagging, loose insulation Securing and Leveling the ApplianceAssembly of Vent Sections DVP Pipe Installing Vent PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsSecuring the Vent Sections Vertical Sections Disassembly of Vent Sections DVP PipeHorizontal Sections Heat Shield Requirements for Horizontal Termination Installing the Horizontal Termination CapInstall Support Brackets Assembly of Vent Sections SL pipeAttach the First Vent Component to Starting Collars Continue Adding Vent ComponentsFire Risk. Explosion Risk Roof Pitch Min. Ft Installing Roof Flashing and Vertical Ter- mination Cap20 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarFuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Connecting to the Appliance Recommendation for WireElectrical Information Standing Pilot Ignition System Wiring Intellifire Ignition System WiringIntellifire Ignition Wiring Diagram with Remote Wall Switch Installation for Fan Optional Junction Box InstallationFinishing Facing Material Facing MaterialSplatter Guard To install the Splatter GuardTo Remove the Splatter Guard To Close the Lower Access PanelSL-350TRS-D350-Template DoorsLava Rock, Mineral Wool/Ember Placement Appliance SetupClean the Appliance AccessoriesInstall logs according to the install manual Install RefractoryStep SL-550TRS-IPI-E and SL-750TRS-IPI-E onlyPositioning the Logs Model SL-350TRS-D Log Set Assembly LOGS-350TRS-DPage Carefully remove the logs from the packaging Model SL-550TRS-IPI-E Log Set Assembly LOGS-SL550TRS-DStep Model SL-750TRS-IPI-E Log Set Assembly LOGS-SL750TRS- D Notch Air Shutter Setting Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyBefore Lighting Appliance Operating InstructionsOn position. The ON/OFF switch may Turn off all electric power to the applianceLighting Appliance IPI Ignition Final inspection byStanding Pilot Ignition For Your Safety Read Before Lighting InstructionsInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System flame has been lit, flame Maintaining and Servicing Appliance Inspect Maintenance Tasks Maintenance TasksReference Materials Appliance Dimension DiagramDVP vent components Vent Components DiagramsEffective MaxLength Horizontal Termination CapRoof Flashing Multi-pak 13-3/4 11-7/8 349 mm 787 mm 13-1/4 367 mm 24-5/8 625 mm 27-1/2 127 mm302 mm 13-3/4 13-7/8 352 mm 349 mmVerticalTermination Cap Highwind DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP Assembly Service Parts Log Set AssemblyPart number list on following Service Parts List SL-350TRS-D Standing Pilot Valve AssemblyTo ensure correct service parts IPI Valve AssemblyPart number list on following 1412Pilot Orifice NG 593-528 Pilot Orifice LP 593-527 Regulator NG Additional service part numbers may appear on followingSL-750TRS-IPI-E SL-750TRS-IPI-E 582-840 Orifice LP #53C 582-583 Orifice NG #37C SL550TRS-IPI-E, SL-750TRS-IPI-ELimited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyContact Information

SL-550TRS-IPI-E, SL-350TRS-IPI, SL-750TRS-IPI-E, SL-350TRS-D specifications

Hearth and Home Technologies has made a significant impact in the hearth and home industry with its innovative line of gas fireplaces, specifically the SL-350TRS-D, SL-750TRS-IPI-E, SL-350TRS-IPI, and SL-550TRS-IPI-E models. Each of these units offers a unique combination of design and functionality, catering to diverse consumer needs.

The SL-350TRS-D is designed to create an inviting ambiance with its linear design and clean lines. It features a powerful remote control system, allowing users to adjust the flame height and heat output effortlessly. The advanced burner technology provides a realistic flame presentation that enhances the overall aesthetic of any space. Additionally, the direct vent system ensures optimal efficiency, channeling combustion gases outside while drawing in fresh air for combustion.

Moving on to the SL-750TRS-IPI-E, this model expands on the features of its predecessor, delivering higher heat output and an even larger viewing area. It includes an Integrated Piezo Ignition (IPI) system that ignites the fireplace at the push of a button, enhancing user convenience. The SL-750TRS-IPI-E also comes with adjustable flames and a selection of decorative media, allowing customers to customize the look to fit their home decor.

The SL-350TRS-IPI offers similar functionalities as the other models but incorporates additional energy-saving technologies. Its modulating gas valve allows for precise temperature control, reducing fuel consumption while maintaining comfortable warmth. Furthermore, this model is equipped with an intuitive smartphone application, providing users with remote access to control the fireplace from anywhere in the home.

Lastly, the SL-550TRS-IPI-E bridges the gap between the other units in terms of size and heat production. Like the SL-750, it features the IPI system for easy ignition and impressive design aesthetics. Its larger viewing area showcases a captivating flame display that serves as a focal point in any room. The fireplace also boasts heat management solutions, allowing for optimal warmth distribution without compromising on energy efficiency.

Overall, Hearth and Home Technologies' SL series offers advanced features and innovative technologies that cater to today’s energy-conscious consumers while creating an appealing environment. With their stylish designs, customizable options, and user-friendly functionalities, these models are set to elevate any home's ambiance. Whether you are looking for efficient heating or a modern design element, these gas fireplaces bring warmth, convenience, and style to the forefront.