TYPICAL INSTALLATION

GET TO KNOW YOUR WATER HEATER - GAS MODELS

A

Vent Pipe

K

Outer door

U

Main Burner

B

Draft hood

L

Union

V

Flue

C

Anode (Not Shown)

M

Inlet Water Shut-off Valve

W

Suitable Metal Drain Pan

D

Hot Water Outlet

N

Cold Water Inlet

X

Control Display

E

Insulation

O

Inlet Dip Tube

Y

Power Supply Transformer

F

Gas Supply Piping

P

Temperature & Pressure Relief Valve

 

(Shown detached from Heater)

G

Manual Gas Shut-off Valve

Q

Rating Plate

YY Pressure Switch

H

Ground Joint Union

R

Flue Baffle

 

(Shown detached from Heater)

I

Drip Leg (Sediment Trap)

S

Gas Control Valve/Thermostat

Z

Air Intake Chamber

J

Inner Door

T

Drain Valve

ZZ

FV Sensor (Shown without Bracket)

*INSTALL IN ACCORDANCE WITH LOCAL CODES.

*DRIP LEG AS REQUIRED

BY LOCAL CODES.

* ALL PIPING MATERIALS

 

TO BE SUPPLIED BY

 

CUSTOMERS.

 

TO VENT TERMINATION

 

ON ROOF

 

A

INSTALL THERMAL EXPANSION

TANK IF WATER HEATER IS

 

 

INSTALLED IN A CLOSED

 

WATER SYSTEM

L

M

N

B

 

 

 

D

 

 

 

O

VACUUM RELIEF

 

 

VALVE

 

 

*INSTALL PER

 

 

LOCAL CODES

E

 

P

 

 

R

X

 

Z

 

Q

F

 

 

 

G

 

 

 

 

 

 

DISCHARGE PIPE

H

 

S

(DO NOT CAP OR PLUG.)

 

 

 

 

V

 

 

 

 

T

I

U

 

 

 

 

6” MAXIMUM

 

 

 

 

 

 

AIR GAP

 

 

 

FLOOR DRAIN

W

 

 

YY

J

ZZ

 

 

 

 

 

 

 

Y

K

 

 

 

 

(S) GAS CONTROL VALVE/THERMOSTAT

IMPORTANT:

WHEN BRUSHING ON AN APPROVED NONCORROSIVE LEAK DETECTION SOLUTION, DO NOT SPLASH SOLUTION ONTO ELECTRICAL CON- NECTIONS (SEE PAGE 27).

 

 

PRESSURE

MANIFOLD TUBE

 

SWITCH/FAN,

 

FV SENSOR

 

 

POWER SUPPLY

IGNITER/

CONNECTOR

 

TRANSFORMER

FLAME

 

CONNECTOR

SENSE

DISPLAY, ANODE

 

CONNECTOR

ROD CONNECTOR

(U) NATURAL GAS BURNER ASSEMBLY

MANIFOLD DOOR GASKET

 

 

MANIFOLD COMPONENT

MANIFOLD DOOR ASSEMBLY

BLOCK W/ RETAINER CLIP

 

 

BURNER

IGNITER / FLAME SENSE

FLAME SENSE

CONNECTOR WIRE

 

 

MANIFOLD

 

HOT SURFACE

TUBE

IGNITER / FLAME SENSE

 

IGNITER

 

CONNECTOR WIRE

MANIFOLD DOOR ASSEMBLY

 

BURNER

 

 

 

 

MANIFOLD TUBE

 

VIEW PORT

 

IMPORTANT: DO NOT USE AN EXTENSION CORD TO CONNECT

THE WATER HEATER TO AN ELECTRICAL OUTLET.

FIGURE 1.

10

Image 10
Contents Gas Water Heater Safe INSTALLATION, USE and Service Safety PrecautionsFire or Explosion Hazard Breathing Hazard Carbon Monoxide GasTable of Contents Troubleshooting Chart Product Warranty Year Limited Warranty on Water HeaterCustomer Responsibilities Important Information About This Water HeaterProduct Specifications GAS PER Hour DIA. InchesMaterials and Basic Tools Needed Materials NeededTypical Installation GET to Know Your Water Heater GAS ModelsWater Heater Location Installation ChecklistImportant Information about this Water Heater Combustion Air Supply and VentilationInstallation Instructions Removing the Old Water HeaterSite Location Location RequirementsCarbon Monoxide Poisoning Hazard Clearances and Accessibility High Altitude InstallationGas Requirements Gas Pressure TestingGAS Supply Gas PipingGas Pipe Capacity Table Confined Space Combustion AIR & VentilationUnconfined Space SquareAll Air from the Building Louvers and GrillesAll Air from Outdoors Draft Hood Installation Vent Pipe SystemChimney Connection Vent ConnectorsVent Pipe Size Vertical Exhaust Gas VentPiping Installation Water System PipingTemperature and Pressure Relief Valve Closed System/Thermal ExpansionTemperature & Pressure Relief Valve Relief Valve and Pipe InsulationElectrical Solar InstallationElectrical Connections Operating Your Water Heater Operating InstructionsBurn Hazard Water Heater OperationChecking the Draft Do not touch vent Doing so can result in burnsBurner Flames Water Temperature RegulationEmergency Shut Down Hotter Cooler Draining and Flushing Service and AdjustmentRoutine Preventive Maintenance Explosion HarzardRemoving the Burner from the Manifold/ Burner Assembly Maintenance of Your Water HeaterReplacement Parts Removing the Manifold/Burner AssemblyCleaning the Combustion Chamber and Air Diverter Assembly Replacing the Manifold/Burner AssemblyRemoving the Gas Control Valve/Thermostat Removing and Replacing the Gas Control Valve/ThermostatReplacing the Gas Valve Troubleshooting Guide Start Up ConditionsCondensation ServiceOperational Conditions Smoke OdorLeakage Checkpoints Pressurized Combustion Chamber System Operational Checklist Troubleshooting ChartSIZZLING-RUMBLING Electronic Control Display Troubleshooting Control Display Status Problem Solution Control Display Status Problem Solution Troubleshooting Flowchart YESPressurized Combustion Chamber Parts Order ListKey Parts Description 153.332620 153.332640 Page Get it fixed, at your home or ours MY-HOME1-800-469-4663

153.33262 specifications

Sears 153.33262 is a well-regarded electronic device in the field of household tools, specifically known as a versatile and reliable multi-function meter. Designed for both novice users and seasoned professionals, this meter is an essential instrument for a wide range of applications, including electrical diagnostics and home repair tasks.

One of the key features of the Sears 153.33262 is its capability to measure both AC and DC voltage, making it suitable for a variety of electrical projects. The device supports voltage measurements up to a specific range, allowing users to conduct thorough checks on outlets, circuits, and battery-powered systems. This versatility makes it an invaluable tool for electricians, technicians, and DIY enthusiasts alike.

In addition to voltage measurement, the Sears 153.33262 also boasts a multimeter functionality that includes current and resistance measurement capabilities. Users can easily measure current in different ranges, which is essential for assessing circuit loads and diagnosing electrical issues. The resistance measurement feature is beneficial for checking the integrity of wiring and components, ensuring that users can troubleshoot and resolve problems efficiently.

The design of the Sears 153.33262 emphasizes user-friendly operation. The meter typically incorporates a large, easy-to-read display that provides clear readings in various lighting conditions. The rotating selector switch allows users to switch between different measurement modes with ease, streamlining the workflow and minimizing the risk of errors.

This device is built with durability in mind, often featuring a rugged casing that can withstand the wear and tear associated with frequent use in various environments. Its portability is enhanced by its lightweight construction, allowing users to carry it easily to different job sites or locations within the home.

Furthermore, the Sears 153.33262 may also include features such as audible alerts for continuity testing, data hold functions, and battery-saving modes, further enhancing its functionality. The availability of probes and leads designed specifically for the meter ensures that users receive accurate measurements consistently.

In summary, the Sears 153.33262 is a multi-function electrical meter that stands out for its combination of versatility, user-friendly features, and robust construction. Whether one is performing simple checks around the house or engaged in complex electrical diagnostics, this meter serves as a reliable companion for all electrical measurement needs.