Sears 153.33262 manual Leakage Checkpoints

Page 35

Leakage Checkpoints

A

C

B

 

 

E

D

 

G

 

 

H

F

I

6” (152.4 mm)

 

MAXIMUM AIR GAP

 

FIGURE 42.

 

B.*Condensation may be seen on pipes in humid weather or pipe connections may be leaking.

C.*The anode rod fitting may be leaking.

D.Small amounts of water from temperature-pressure relief valve may be due to thermal expansion or high water pressure in your area.

E.*The temperature-pressure relief valve may be leaking at the tank fitting.

F.Water from a drain valve may be due to the valve being slightly opened.

G.*The drain valve may be leaking at the tank fitting.

H.Combustion products contain water vapor which can condense on the cooler surfaces of the tank. Droplets form and drip onto the burner or run on the floor. This is common at the time of start-up after installation and when incoming water is cold.

I.Water in the water heater bottom or on the floor may be from condensation, loose connections, or the relief valve. DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken.

Leakage from other appliances, water lines, or ground seepage should also be checked.

*To check where threaded portion enters tank, insert cotton swab between jacket opening and fitting. If cotton is wet, follow draining instructions in the “Draining and Flushing” section and then remove fitting. Put pipe dope or teflon tape on the threads and replace. When you are finished, follow the steps in “Filling the Water Heater” in the Installation Instructions earlier in this manual.

Teflon® is a registered trademark of E.I. Du Pont De Numours and Company.

Read this manual first. Then, before checking the water heater, make sure the gas supply has been turned “OFF”, and never turn the gas “ON” before the tank is completely full of water.

Never use this water heater unless it is completely filled with water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning “ON” gas to the water heater.

A.Water at the draft hood is water vapor which has condensed out of the combustion products. This is caused by a problem in the vent. Contact a qualified technician.

35

Image 35
Contents Gas Water Heater Safety Precautions Safe INSTALLATION, USE and ServiceBreathing Hazard Carbon Monoxide Gas Fire or Explosion HazardTable of Contents Troubleshooting Chart Year Limited Warranty on Water Heater Product WarrantyImportant Information About This Water Heater Customer ResponsibilitiesGAS PER Hour DIA. Inches Product SpecificationsMaterials Needed Materials and Basic Tools NeededGET to Know Your Water Heater GAS Models Typical InstallationCombustion Air Supply and Ventilation Installation ChecklistImportant Information about this Water Heater Water Heater LocationRemoving the Old Water Heater Installation InstructionsCarbon Monoxide Poisoning Hazard Location RequirementsSite Location High Altitude Installation Clearances and AccessibilityGas Piping Gas Pressure TestingGAS Supply Gas RequirementsGas Pipe Capacity Table Square Combustion AIR & VentilationUnconfined Space Confined SpaceAll Air from Outdoors Louvers and GrillesAll Air from the Building Vent Pipe System Draft Hood InstallationVertical Exhaust Gas Vent Vent ConnectorsVent Pipe Size Chimney ConnectionWater System Piping Piping InstallationClosed System/Thermal Expansion Temperature and Pressure Relief ValveRelief Valve and Pipe Insulation Temperature & Pressure Relief ValveElectrical Connections Solar InstallationElectrical Operating Instructions Operating Your Water HeaterDo not touch vent Doing so can result in burns Water Heater OperationChecking the Draft Burn HazardEmergency Shut Down Water Temperature RegulationBurner Flames Hotter Cooler Explosion Harzard Service and AdjustmentRoutine Preventive Maintenance Draining and FlushingRemoving the Manifold/Burner Assembly Maintenance of Your Water HeaterReplacement Parts Removing the Burner from the Manifold/ Burner AssemblyReplacing the Manifold/Burner Assembly Cleaning the Combustion Chamber and Air Diverter AssemblyReplacing the Gas Valve Removing and Replacing the Gas Control Valve/ThermostatRemoving the Gas Control Valve/Thermostat Start Up Conditions Troubleshooting GuideSmoke Odor ServiceOperational Conditions CondensationLeakage Checkpoints Troubleshooting Chart Pressurized Combustion Chamber System Operational ChecklistSIZZLING-RUMBLING Electronic Control Display Troubleshooting Control Display Status Problem Solution Control Display Status Problem Solution YES Troubleshooting FlowchartKey Parts Description 153.332620 153.332640 Parts Order ListPressurized Combustion Chamber Page MY-HOME1-800-469-4663 Get it fixed, at your home or ours

153.33262 specifications

Sears 153.33262 is a well-regarded electronic device in the field of household tools, specifically known as a versatile and reliable multi-function meter. Designed for both novice users and seasoned professionals, this meter is an essential instrument for a wide range of applications, including electrical diagnostics and home repair tasks.

One of the key features of the Sears 153.33262 is its capability to measure both AC and DC voltage, making it suitable for a variety of electrical projects. The device supports voltage measurements up to a specific range, allowing users to conduct thorough checks on outlets, circuits, and battery-powered systems. This versatility makes it an invaluable tool for electricians, technicians, and DIY enthusiasts alike.

In addition to voltage measurement, the Sears 153.33262 also boasts a multimeter functionality that includes current and resistance measurement capabilities. Users can easily measure current in different ranges, which is essential for assessing circuit loads and diagnosing electrical issues. The resistance measurement feature is beneficial for checking the integrity of wiring and components, ensuring that users can troubleshoot and resolve problems efficiently.

The design of the Sears 153.33262 emphasizes user-friendly operation. The meter typically incorporates a large, easy-to-read display that provides clear readings in various lighting conditions. The rotating selector switch allows users to switch between different measurement modes with ease, streamlining the workflow and minimizing the risk of errors.

This device is built with durability in mind, often featuring a rugged casing that can withstand the wear and tear associated with frequent use in various environments. Its portability is enhanced by its lightweight construction, allowing users to carry it easily to different job sites or locations within the home.

Furthermore, the Sears 153.33262 may also include features such as audible alerts for continuity testing, data hold functions, and battery-saving modes, further enhancing its functionality. The availability of probes and leads designed specifically for the meter ensures that users receive accurate measurements consistently.

In summary, the Sears 153.33262 is a multi-function electrical meter that stands out for its combination of versatility, user-friendly features, and robust construction. Whether one is performing simple checks around the house or engaged in complex electrical diagnostics, this meter serves as a reliable companion for all electrical measurement needs.