Sears 153.33262 manual Location Requirements, Site Location, Carbon Monoxide Poisoning Hazard

Page 13

Location Requirements

WARNING

Carbon Monoxide Poisoning Hazard

Do not install in a mobile home.

Doing so can result in carbon monoxide poisoning and death.

The FVIR System is designed to reduce the risk of flammable vapor-related fires. Flammable liquids (such as gasoline, solvents, propane, etc,) emit flammable vapors which can be ignited by a gas water heater’s hot surface igniter or main burner. The resulting flashback and fire can cause death or serious burns to anyone in the area.

FIGURE 8.

FV Sensor

This heater is equipped with a FV sensor for detecting the presence of flammable vapors. When the sensor detects those vapors, the unit will shut down and not operate. Should this happen, please refer to the troubleshooting guide on pages 38-40 (numbers 9,11,12). Even though this water heater is a flammable vapors ignition resistant water heater and is designed to reduce the chances of flammable vapors being ignited, gasoline and other flammable substances should never be stored or used in the same vicinity or area containing a gas water heater or other open flame or spark producing appliance.

WARNING

FLAMMABLES

Flammable Vapors

FIRE AND EXPLOSION HAZARD

Can result in serious injury or death

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Storage of or use of gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance can result in serious injury or death.

Read and follow water heater warnings and instructions

Do not use or store flammable products such as gasoline, solvents, or adhesives in the same room or area near the water heater. If such flammables must be used, all gas burning appliances in the vicinity must be shut off and their pilot lights extinguished. Open the doors and windows for ventilation while flammable substances are in use.

If flammable liquids or vapors have spilled or leaked in the area of the water heater, leave the area immediately and call the fire department from a neighbor’s home. Do not attempt to clean the spill until all ignition sources have been extinguished.

WARNING

Fire or Explosion Hazard

Read instruction manual before installing, using or servicing water heater.

Improper use may result in fire or explosion.

Maintain required clearances to combustibles.

Keep combustibles such as boxes, magazines, clothes, etc. away from the water heater area.

Site Location

Select a location near the center of the water piping system. The water heater must be installed indoors and in a vertical position on a level surface. DO NOT install in bathrooms, bedrooms, or any occupied room normally kept closed.

Locate the water heater as close to the chimney or gas vent as practical. Consider the vent system piping and combus- tion air supply requirements when selecting the water heater location. The venting system must be able to run from the water heater to termination with minimal length and elbows.

Locate the water heater near the existing gas piping. If installing a new gas line, locate the water heater to minimize the pipe length and elbows.

The water heater should be located in an area not subject to freezing temperatures. Water heaters located in unconditioned spaces (i.e., attics, basements, etc.) may require insulation of the water piping and drain piping to protect against freezing. The drain and controls must be easily accessible for operation and service. Maintain proper clearances as specified on the water heater.

Do not locate the water heater near an air-moving device. The operation of air-moving devices such as exhaust fans, ventilation systems, clothes dryers, fireplaces, etc., can af- fect the proper operation of the water heater. Special atten- tion must be given to conditions these devices may create.

Flow reversal of flue gases may cause an increase of carbon monoxide inside of the dwelling (Figure 10).

The water heater is to be located as close as possible to a 120VAC outlet. NOTE: all electrical wiring should be in accordance to the NEC and all local/state electrical codes (extension cord is not allowed).

NOTE: This water heater must be installed according to all local and state codes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-current edition and the “National Electrical Code”, ANSI/NFPS 70 current edition.

13

Image 13
Contents Gas Water Heater Safety Precautions Safe INSTALLATION, USE and ServiceBreathing Hazard Carbon Monoxide Gas Fire or Explosion HazardTable of Contents Troubleshooting Chart Year Limited Warranty on Water Heater Product WarrantyImportant Information About This Water Heater Customer ResponsibilitiesGAS PER Hour DIA. Inches Product SpecificationsMaterials Needed Materials and Basic Tools NeededGET to Know Your Water Heater GAS Models Typical InstallationImportant Information about this Water Heater Installation ChecklistWater Heater Location Combustion Air Supply and VentilationRemoving the Old Water Heater Installation InstructionsSite Location Location RequirementsCarbon Monoxide Poisoning Hazard High Altitude Installation Clearances and AccessibilityGAS Supply Gas Pressure TestingGas Requirements Gas PipingGas Pipe Capacity Table Unconfined Space Combustion AIR & VentilationConfined Space SquareAll Air from the Building Louvers and GrillesAll Air from Outdoors Vent Pipe System Draft Hood InstallationVent Pipe Size Vent ConnectorsChimney Connection Vertical Exhaust Gas VentWater System Piping Piping InstallationClosed System/Thermal Expansion Temperature and Pressure Relief ValveRelief Valve and Pipe Insulation Temperature & Pressure Relief ValveElectrical Solar InstallationElectrical Connections Operating Instructions Operating Your Water HeaterChecking the Draft Water Heater OperationBurn Hazard Do not touch vent Doing so can result in burnsBurner Flames Water Temperature RegulationEmergency Shut Down Hotter Cooler Routine Preventive Maintenance Service and AdjustmentDraining and Flushing Explosion HarzardReplacement Parts Maintenance of Your Water HeaterRemoving the Burner from the Manifold/ Burner Assembly Removing the Manifold/Burner AssemblyReplacing the Manifold/Burner Assembly Cleaning the Combustion Chamber and Air Diverter AssemblyRemoving the Gas Control Valve/Thermostat Removing and Replacing the Gas Control Valve/ThermostatReplacing the Gas Valve Start Up Conditions Troubleshooting GuideOperational Conditions ServiceCondensation Smoke OdorLeakage Checkpoints Troubleshooting Chart Pressurized Combustion Chamber System Operational ChecklistSIZZLING-RUMBLING Electronic Control Display Troubleshooting Control Display Status Problem Solution Control Display Status Problem Solution YES Troubleshooting FlowchartPressurized Combustion Chamber Parts Order ListKey Parts Description 153.332620 153.332640 Page MY-HOME1-800-469-4663 Get it fixed, at your home or ours

153.33262 specifications

Sears 153.33262 is a well-regarded electronic device in the field of household tools, specifically known as a versatile and reliable multi-function meter. Designed for both novice users and seasoned professionals, this meter is an essential instrument for a wide range of applications, including electrical diagnostics and home repair tasks.

One of the key features of the Sears 153.33262 is its capability to measure both AC and DC voltage, making it suitable for a variety of electrical projects. The device supports voltage measurements up to a specific range, allowing users to conduct thorough checks on outlets, circuits, and battery-powered systems. This versatility makes it an invaluable tool for electricians, technicians, and DIY enthusiasts alike.

In addition to voltage measurement, the Sears 153.33262 also boasts a multimeter functionality that includes current and resistance measurement capabilities. Users can easily measure current in different ranges, which is essential for assessing circuit loads and diagnosing electrical issues. The resistance measurement feature is beneficial for checking the integrity of wiring and components, ensuring that users can troubleshoot and resolve problems efficiently.

The design of the Sears 153.33262 emphasizes user-friendly operation. The meter typically incorporates a large, easy-to-read display that provides clear readings in various lighting conditions. The rotating selector switch allows users to switch between different measurement modes with ease, streamlining the workflow and minimizing the risk of errors.

This device is built with durability in mind, often featuring a rugged casing that can withstand the wear and tear associated with frequent use in various environments. Its portability is enhanced by its lightweight construction, allowing users to carry it easily to different job sites or locations within the home.

Furthermore, the Sears 153.33262 may also include features such as audible alerts for continuity testing, data hold functions, and battery-saving modes, further enhancing its functionality. The availability of probes and leads designed specifically for the meter ensures that users receive accurate measurements consistently.

In summary, the Sears 153.33262 is a multi-function electrical meter that stands out for its combination of versatility, user-friendly features, and robust construction. Whether one is performing simple checks around the house or engaged in complex electrical diagnostics, this meter serves as a reliable companion for all electrical measurement needs.