Sears 153.33262 manual Control Display Status Problem Solution

Page 39

 

CONTROL DISPLAY STATUS

PROBLEM

 

SOLUTION

 

 

 

 

6.

“P-SW”, “OPEN”, and “CLEAN SCREEN” Flashing

 

1. Clean the screen on the combustion air

The air pressure switch contacts

intake chamber. Turn the power “OFF” for

 

 

remain open longer than 11

10 to 20 seconds then “ON” again to clear

 

 

seconds after the combustion fan

the error code. If the problem persists:

 

 

is energized.

2. Ensure the pressure switch sensing tube

 

 

 

is in good condition and securely

 

 

 

connected at both ends.

 

 

 

3. Ensure the inner door to the combustion

 

 

 

chamber is secure and the gasket is

 

 

 

properly sealing.

 

 

 

4. Check operation of the air intake chamber

 

 

 

fan and pressure switch.

 

 

 

A.

Turn off power to the water heater.

 

 

 

B. Remove the tubing from the pressure

 

 

 

 

switch and the wires from both

 

 

 

 

terminals of the pressure switch.

 

 

 

C. Connect a digital manometer to the

 

 

 

 

open end of the tubing from the air

 

 

 

 

intake chamber. Turn on the power to

 

 

 

 

the water heater and when the fan turns

 

 

 

 

on, measure the pressure reading in the

 

 

 

 

tubing. If the pressure reading reaches

 

 

 

 

the .22” WC make point of the pressure

 

 

 

 

switch, turn off power to the water

 

 

 

 

heater and reconnect tubing to the

 

 

 

 

pressure switch. If pressure reading does

 

 

 

 

not reach the .22” WC make point, check

 

 

 

 

the system and tubing for restrictions

 

 

 

 

and cleanliness.

 

 

 

D. Attach leads of ohmmeter or continuity

 

 

 

 

tester to the terminals of the pressure

 

 

 

 

switch. Turn on power to the water

 

 

 

 

heater and when the air intake fan

 

 

 

 

comes on, check for continuity across

 

 

 

 

the pressure switch contacts. If switch

 

 

 

 

contacts remain open (no continuity)

 

 

 

 

while the fan is in operation - replace

 

 

 

 

the pressure switch.

7.

“P-SW” and “SHORT” Flashing

The air pressure switch contacts

1. Turn off power to the water heater.

2. Locate the pressure switch wiring –

 

 

remain closed for more than 5

 

 

ensure pressure switch wiring is correct

 

 

seconds when they should be

 

 

and not jumped.

 

 

open.

 

 

3. Remove wires to both terminals on

 

 

 

 

 

 

pressure switch.

 

 

 

4. Check pressure switch contacts with an

 

 

 

ohmmeter for continuity.

 

 

 

A.

If pressure switch contacts show

 

 

 

 

continuity (closed circuit) replace

 

 

 

 

the pressure switch.

 

 

 

B.

If pressure switch contacts show

 

 

 

 

open circuit and all wiring is correct

 

 

 

 

– replace the lower control.

8.

“IGN” Flashing

Open ignitor circuit

1. Check all wiring to the hot surface ignitor.

2. Check the 3 pin Molex ignitor assembly

 

 

 

 

 

 

plug and receptacle on the lower control

 

 

 

for a good connection. Repair or replace

 

 

 

parts if necessary.

 

 

 

3. Check resistance of the ignitor with an

 

 

 

ohmmeter on the ignitor assembly plug.

 

 

 

Replace ignitor if resistance is not within

 

 

 

1.72 and 2.40 ohms.

 

 

 

4. If above checks are good – turn off

 

 

 

power for 10 seconds and then back on.

 

 

 

If this error code will not clear and the

 

 

 

ignitor resistance is within specifications

 

 

 

– replace the lower control.

9.

“FV-SENSE” Flashing

Flammable Vapor Sensor has

1. Do not touch any electrical switch, do not use

 

 

detected the presence of

any phone in the building and do not try to

 

 

flammable vapors and is in lockout

light any appliance.

 

 

 

2. Smell around the water heater to ensure there

 

 

 

are no gas leaks at the gas control valve or in

 

 

 

the supply gas line or for any other type of

 

 

 

flammable vapors in the area.

 

 

 

3. Carefully inspect the area surrounding the

 

 

 

water heater for any substances such as gas-

 

 

 

oline, paint, paint thinners, varnish, or cleaners

 

 

 

that could emit flammable vapors. Remove

 

 

 

anything that can potentially emit flammable

 

 

 

vapors from the area and store it properly in a

 

 

 

different location.

 

 

 

 

~ continued next page ~

 

 

 

 

 

39

Image 39
Contents Gas Water Heater Safety Precautions Safe INSTALLATION, USE and ServiceBreathing Hazard Carbon Monoxide Gas Fire or Explosion HazardTable of Contents Troubleshooting Chart Year Limited Warranty on Water Heater Product WarrantyImportant Information About This Water Heater Customer ResponsibilitiesGAS PER Hour DIA. Inches Product SpecificationsMaterials Needed Materials and Basic Tools NeededGET to Know Your Water Heater GAS Models Typical InstallationCombustion Air Supply and Ventilation Installation ChecklistImportant Information about this Water Heater Water Heater LocationRemoving the Old Water Heater Installation InstructionsLocation Requirements Site LocationCarbon Monoxide Poisoning Hazard High Altitude Installation Clearances and AccessibilityGas Piping Gas Pressure TestingGAS Supply Gas RequirementsGas Pipe Capacity Table Square Combustion AIR & VentilationUnconfined Space Confined SpaceLouvers and Grilles All Air from the BuildingAll Air from Outdoors Vent Pipe System Draft Hood InstallationVertical Exhaust Gas Vent Vent ConnectorsVent Pipe Size Chimney ConnectionWater System Piping Piping InstallationClosed System/Thermal Expansion Temperature and Pressure Relief ValveRelief Valve and Pipe Insulation Temperature & Pressure Relief ValveSolar Installation ElectricalElectrical Connections Operating Instructions Operating Your Water HeaterDo not touch vent Doing so can result in burns Water Heater OperationChecking the Draft Burn HazardWater Temperature Regulation Burner FlamesEmergency Shut Down Hotter Cooler Explosion Harzard Service and AdjustmentRoutine Preventive Maintenance Draining and FlushingRemoving the Manifold/Burner Assembly Maintenance of Your Water HeaterReplacement Parts Removing the Burner from the Manifold/ Burner AssemblyReplacing the Manifold/Burner Assembly Cleaning the Combustion Chamber and Air Diverter AssemblyRemoving and Replacing the Gas Control Valve/Thermostat Removing the Gas Control Valve/ThermostatReplacing the Gas Valve Start Up Conditions Troubleshooting GuideSmoke Odor ServiceOperational Conditions CondensationLeakage Checkpoints Troubleshooting Chart Pressurized Combustion Chamber System Operational ChecklistSIZZLING-RUMBLING Electronic Control Display Troubleshooting Control Display Status Problem Solution Control Display Status Problem Solution YES Troubleshooting FlowchartParts Order List Pressurized Combustion ChamberKey Parts Description 153.332620 153.332640 Page MY-HOME1-800-469-4663 Get it fixed, at your home or ours

153.33262 specifications

Sears 153.33262 is a well-regarded electronic device in the field of household tools, specifically known as a versatile and reliable multi-function meter. Designed for both novice users and seasoned professionals, this meter is an essential instrument for a wide range of applications, including electrical diagnostics and home repair tasks.

One of the key features of the Sears 153.33262 is its capability to measure both AC and DC voltage, making it suitable for a variety of electrical projects. The device supports voltage measurements up to a specific range, allowing users to conduct thorough checks on outlets, circuits, and battery-powered systems. This versatility makes it an invaluable tool for electricians, technicians, and DIY enthusiasts alike.

In addition to voltage measurement, the Sears 153.33262 also boasts a multimeter functionality that includes current and resistance measurement capabilities. Users can easily measure current in different ranges, which is essential for assessing circuit loads and diagnosing electrical issues. The resistance measurement feature is beneficial for checking the integrity of wiring and components, ensuring that users can troubleshoot and resolve problems efficiently.

The design of the Sears 153.33262 emphasizes user-friendly operation. The meter typically incorporates a large, easy-to-read display that provides clear readings in various lighting conditions. The rotating selector switch allows users to switch between different measurement modes with ease, streamlining the workflow and minimizing the risk of errors.

This device is built with durability in mind, often featuring a rugged casing that can withstand the wear and tear associated with frequent use in various environments. Its portability is enhanced by its lightweight construction, allowing users to carry it easily to different job sites or locations within the home.

Furthermore, the Sears 153.33262 may also include features such as audible alerts for continuity testing, data hold functions, and battery-saving modes, further enhancing its functionality. The availability of probes and leads designed specifically for the meter ensures that users receive accurate measurements consistently.

In summary, the Sears 153.33262 is a multi-function electrical meter that stands out for its combination of versatility, user-friendly features, and robust construction. Whether one is performing simple checks around the house or engaged in complex electrical diagnostics, this meter serves as a reliable companion for all electrical measurement needs.