Sears 153.33262 manual Closed System/Thermal Expansion, Temperature and Pressure Relief Valve

Page 22
Pressure Reducing Valve with Bypass
Main Water Supply

Hot Water Outlet

Metal Drain

Pan 1-3/4”

Depth Max.

In a closed system use a thermal expansion tank

Cold Water

Inlet Valve

Cold Water Supply to Fixture

Temperature and Pressure (T&P)

Relief Valve (Optional Top T&P

Relief Valve Not Shown)

Massachusetts: Install a vacuum relief in cold water line per section 19 MGL 142

Discharge line

(Do Not Cap or Plug)

1“ Min.

Drain line 3/4”

ID Min.

 

Drain

6“ Min.

Closed System/Thermal Expansion

As water is heated, it expands (thermal expansion). In a closed system, the volume of water will grow. As the volume of water grows, there will be a corresponding increase in water pressure due to thermal expansion. Thermal expansion can cause premature tank failure (leakage). This type of failure is not covered under the limited warranty. Thermal expansion can also cause intermittent temperature-pressure relief valve operation: water discharged from the valve due to excessive pressure build

Typical water piping installation

FIGURE 23.

Mixed Water

To Fixtures

Unmixed

Hot Water

Cold Water

Inlet

Hot Water

Outlet

Mixing Valve

(Set To 1200 F)

Follow The Mixing Valve

Manufacturer’s Instructions

FIGURE 24.

Please note the following:

up. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This condition is not covered under the limited warranty.

A properly-sized thermal expansion tank should be installed on all closed systems to control the harmful effects of thermal expansion. Contact a plumbing service agency or your retail supplier regarding the installation of a thermal expansion tank.

Temperature and Pressure Relief Valve

Explosion Hazard

Temperature-pressure relief valve must comply with ANSI Z21.22-CSA 4.4 and ASME code.

• Properly sized temperature- pressure relief valve must be installed in opening provided.

• Can result in overheating and excessive tank pressure.

• Can cause serious injury or death.

• The system should be installed only with piping that is suitable

for potable (drinkable) water such as copper, CPVC, or

polybutylene. This water heater must not be installed using

iron piping or PVC water piping.

• Use only pumps, valves, or fittings that are compatible with

potable water.

• It is recommend that only full flow ball or gate valves are used

in water piping installations. The use of valves that may cause

excessive restriction to water flow is not recommended.

• Use only 95/5 tin-antimony or other equivalent solder. Any

lead based solder must not be used.

• Piping that has been treated with chromates, boiler seal, or

other chemicals must not be used.

Metal Drain Pan

Temperature and

Pressure Relief Valve

(T&P)

Discharge line 3/4” Min.

Do not cap or plug.

6” Max.

Drain

• Chemicals that may contaminate the potable water supply

must not be added to the piping system.

FIGURE 25.

22

Image 22
Contents Gas Water Heater Safe INSTALLATION, USE and Service Safety PrecautionsFire or Explosion Hazard Breathing Hazard Carbon Monoxide GasTable of Contents Troubleshooting Chart Product Warranty Year Limited Warranty on Water HeaterCustomer Responsibilities Important Information About This Water HeaterProduct Specifications GAS PER Hour DIA. InchesMaterials and Basic Tools Needed Materials NeededTypical Installation GET to Know Your Water Heater GAS ModelsWater Heater Location Installation ChecklistImportant Information about this Water Heater Combustion Air Supply and VentilationInstallation Instructions Removing the Old Water HeaterSite Location Location RequirementsCarbon Monoxide Poisoning Hazard Clearances and Accessibility High Altitude InstallationGas Requirements Gas Pressure TestingGAS Supply Gas PipingGas Pipe Capacity Table Confined Space Combustion AIR & VentilationUnconfined Space SquareAll Air from the Building Louvers and GrillesAll Air from Outdoors Draft Hood Installation Vent Pipe SystemChimney Connection Vent ConnectorsVent Pipe Size Vertical Exhaust Gas VentPiping Installation Water System PipingTemperature and Pressure Relief Valve Closed System/Thermal ExpansionTemperature & Pressure Relief Valve Relief Valve and Pipe InsulationElectrical Solar InstallationElectrical Connections Operating Your Water Heater Operating InstructionsBurn Hazard Water Heater OperationChecking the Draft Do not touch vent Doing so can result in burnsBurner Flames Water Temperature RegulationEmergency Shut Down Hotter Cooler Draining and Flushing Service and AdjustmentRoutine Preventive Maintenance Explosion HarzardRemoving the Burner from the Manifold/ Burner Assembly Maintenance of Your Water HeaterReplacement Parts Removing the Manifold/Burner AssemblyCleaning the Combustion Chamber and Air Diverter Assembly Replacing the Manifold/Burner AssemblyRemoving the Gas Control Valve/Thermostat Removing and Replacing the Gas Control Valve/ThermostatReplacing the Gas Valve Troubleshooting Guide Start Up ConditionsCondensation ServiceOperational Conditions Smoke OdorLeakage Checkpoints Pressurized Combustion Chamber System Operational Checklist Troubleshooting ChartSIZZLING-RUMBLING Electronic Control Display Troubleshooting Control Display Status Problem Solution Control Display Status Problem Solution Troubleshooting Flowchart YESPressurized Combustion Chamber Parts Order ListKey Parts Description 153.332620 153.332640 Page Get it fixed, at your home or ours MY-HOME1-800-469-4663

153.33262 specifications

Sears 153.33262 is a well-regarded electronic device in the field of household tools, specifically known as a versatile and reliable multi-function meter. Designed for both novice users and seasoned professionals, this meter is an essential instrument for a wide range of applications, including electrical diagnostics and home repair tasks.

One of the key features of the Sears 153.33262 is its capability to measure both AC and DC voltage, making it suitable for a variety of electrical projects. The device supports voltage measurements up to a specific range, allowing users to conduct thorough checks on outlets, circuits, and battery-powered systems. This versatility makes it an invaluable tool for electricians, technicians, and DIY enthusiasts alike.

In addition to voltage measurement, the Sears 153.33262 also boasts a multimeter functionality that includes current and resistance measurement capabilities. Users can easily measure current in different ranges, which is essential for assessing circuit loads and diagnosing electrical issues. The resistance measurement feature is beneficial for checking the integrity of wiring and components, ensuring that users can troubleshoot and resolve problems efficiently.

The design of the Sears 153.33262 emphasizes user-friendly operation. The meter typically incorporates a large, easy-to-read display that provides clear readings in various lighting conditions. The rotating selector switch allows users to switch between different measurement modes with ease, streamlining the workflow and minimizing the risk of errors.

This device is built with durability in mind, often featuring a rugged casing that can withstand the wear and tear associated with frequent use in various environments. Its portability is enhanced by its lightweight construction, allowing users to carry it easily to different job sites or locations within the home.

Furthermore, the Sears 153.33262 may also include features such as audible alerts for continuity testing, data hold functions, and battery-saving modes, further enhancing its functionality. The availability of probes and leads designed specifically for the meter ensures that users receive accurate measurements consistently.

In summary, the Sears 153.33262 is a multi-function electrical meter that stands out for its combination of versatility, user-friendly features, and robust construction. Whether one is performing simple checks around the house or engaged in complex electrical diagnostics, this meter serves as a reliable companion for all electrical measurement needs.