Carrier 33CS400-01 owner manual Explanation of Jumper Settings, HUM Jumper Setting

Page 68

Explanation of Jumper Settings

HUM JUMPER SETTING

If the jumper for MISC1, MISC2, or MISC3 is set to HUM, the corresponding MISC screw terminal on the backplate will control a humidification system.

HUMIDIFICATION OPERATION - SECTION 8

If your HVAC unit is equipped with a humidification system and the Humidity Module (sold separately) has been installed, the thermostat will provide power to the MISC1, MISC2, or MISC3 terminal of the thermostat when the humidity in the home falls below the humidity setpoint you have chosen. The value for this setpoint ranges from 0% to 60%. If no humidity is desired or if a humidification system has not been installed, set the value to 0%.

DEHUM JUMPER SETTING

If the jumper for MISC1, MISC2, or MISC3 is set to DEHUM, the corresponding MISC screw terminal on the backplate will be connected to the dehumidification terminal of a furnace board. NOTE: Not all furnaces have a dehumidification terminal.

DEHUMIDIFICATION OPERATION - SECTION 9

If your HVAC unit is equipped with a dehumidification system the thermostat will operate in one of two ways.

1)Normally Closed (NC): The thermostat will de-energizethe MISC1, MISC2,

or MISC3 terminal of the thermostat (this MISC terminal is connected

to the DEHUM terminal on your furnace) to allow the fan to run in low 16 speed when the humidity in the home is above the dehumidify setpoint you have chosen and there is a call for 1st stage cooling.

2)Normally Open (NO): The thermostat will energize the MISC1, MISC2, or MISC3 terminal of the thermostat (this MISC terminal is connected to the DEHUM terminal on your furnace) to allow the fan to run in low speed when the humidity in the home is above the dehumidify setpoint you have chosen and there is a call for 1st stage cooling.

Page 16.3

Image 68
Contents OWNER’S 4Z95 How to Use This Manual Glossary of Terms Page Table of Contents Contents Selecting the Heat or Cool Mode Heating OnlyHeating or Cooling OffSelecting Your Desired Temperature Adjusting the setpointsContents Front Panel ButtonDisplay Features CoolService Filter icon Section Humidify/DeHumidify icon Sections Contents To enter Setup screens Press the Mode button repeatedlyUntil this setup screen appears Manual or Auto-Changeover ThermostatOperating Mode when the Thermostat is Configured to be Cooling OnlyHeating or Cooling Selecting Your Desired Temperature adjusting setpoints Viewing the Outside Temperature Viewing the Indoor Humidity Viewing the Outside Temperature Press the Outside button to view the Outside temperatureViewing the Indoor Humidity To view the indoor humidityOverride Operation Overriding the Normal OperationSetting the Fan-Off Time Using the Fan Button Smart Fan OperationUsing the Fan Button Smart Fan OperationSetting the Fan-Off Time Delay Programming a Security LevelAfter a button press Locking/Unlocking the Keypad Appear on the display, then release the buttonsProgramming a Security Level Installing the Humidity SetpointInstalling the Humidity Module Back of 33CS400-01Setting a Thermostat Jumper for Humidity Operation MISC3 outputs, please see SectionAdjusting the Humidification Setpoint Press the HumidityUsing Your Air Conditioner To Dehumidify Using the Dehum TerminalSetting a Thermostat Jumper for Dehumidification Operation Adjusting the Dehumidification Setpoint Press the Mode button onceUsing Your Air Conditioner to Dehumidify Appears only if is set to onUsing the Dehum Terminal Run-Time 10.4 Run-Time 10.2Run-Time 10.3 Viewing the Override Operation Run-Time Viewing the Humidification Run-Time Viewing the UV Light Run-Time Electric Heat and Heat Pump Operation Viewing the Heat Pump Reversing Valve Jumper Settings OFF = Gas Electric OperationViewing the Electric Heat Jumper Setting Using Emergency Heat 73 74HEAT12.3 Adjusting the Heat/Cool Differential Adjusting the Cycles Per Hour Adjusting the Deadband Adjust the deadband For the 1st stage Selecting 2nd Stage Turn Off Temperature Select On or Off On 2nd stage will13.2 Installing the RemoteControlling or Reading Remote Temperature RS1...13.3 Installing the Remote Sensors Controlling or Reading Remote Temperature RS1 Dry Contact Operation 14.2 Dry Contact Programming 14.314.4 14.5Dry Contact Operation Appears only if is YESService Pan Dry Contact ProgrammingUnoccupied Random Start Operation Setting and Resetting Service Filter Fan Run-Time 15.2Press the Reset Filter button To enter this setup screenHow to Set and Reset the UV Light Run-Time Alert How to Set and Reset the Humidifier Run-Time Alert Until this setup screen appearsConfiguring the Jumpers 16.2 16.3Configuring the Jumpers MISC3 MISC2 MISC1Explanation of Jumper Settings HUM Jumper SettingY2 Jumper Setting Factory Defaults, Calibration, and Sensors Resetting the Thermostat to Factory Default Settings for default values seeCalibrating the Temperature and Humidity Sensors I200 PmAccessories Advanced Setup Table Index Electric Heating Index See DisplaySetpoint Warranty

33CS400-01 specifications

The Carrier 33CS400-01 is a highly efficient air conditioning system designed for residential and light commercial use, providing exceptional cooling performance with a focus on energy efficiency. This model is part of Carrier's comprehensive range of HVAC solutions, ensuring comfort while minimizing environmental impact.

One of the standout features of the 33CS400-01 is its Energy Efficiency Ratio (EER) and Seasonal Energy Efficiency Ratio (SEER). Specifically engineered for optimal performance, this unit promotes lower energy consumption, which translates to significant cost savings for homeowners. Its SEER rating often exceeds standard benchmarks, making it an environmentally friendly choice without sacrificing comfort.

The 33CS400-01 showcases advanced technologies such as the WeatherShield protection. This sturdy feature enhances the unit's durability, allowing it to withstand various weather conditions and prolonging its lifespan. With a compact design, it is ideal for installation in different spaces, catering to those with limited outdoor areas.

Another notable characteristic of the Carrier 33CS400-01 is its sound performance. The unit is designed with quiet operation in mind, utilizing advanced sound-dampening technology. This ensures that users can enjoy a peaceful indoor environment without the intrusive noise commonly associated with conventional air conditioning systems.

The unit also includes a multi-speed fan motor which contributes to its overall efficiency and user control. This motor adapts to the cooling demands, allowing for consistent comfort while reducing energy expenditure. Coupled with a reliable compressor, the system provides rapid cooling, making it suitable for even the hottest of climates.

For ease of maintenance, the Carrier 33CS400-01 features a simplified access panel, allowing technicians or homeowners to perform routine checks and maintenance with minimal hassle. This commitment to user-friendly design ensures that the system remains in peak condition throughout its lifecycle.

In summary, the Carrier 33CS400-01 air conditioning unit combines energy efficiency, quiet operation, and robust durability. With cutting-edge technologies and a design catered to convenience, it stands as a reliable choice for consumers looking to enhance their indoor air comfort while also being mindful of energy consumption.