Bryant PSPHA732 warranty

Page 1

PSPHA732

SMART TEMP® ELECTRONIC THERMOSTAT

INSTALLATION AND OPERATING INSTRUCTIONS

Easy as 1–2–3

Installs Easily

Set Day & Time

Choose Heat or Cool

IMPORTANT!

Please read all instructions carefully before beginning installation. Save them for future reference.

Before removing any wiring from your existing thermostat, its wires must be labeled with their terminal designations.

Ignore the color of the wires since they may not comply with any standard.

Thank you for your confidence in our product. To obtain the best results from your investment, please read these instructions and acquaint yourself with your purchase before installing your new thermostat. Then follow the installation procedures, one step at a time. This will save you time and minimize the chance of damaging the thermostat and the systems it controls.

These instructions may contain information beyond that required for your particular installation. Please save for future reference.

1. COMPATIBILITY . . . . . . . . . . . . . . . . . . . . . . . . 2

2. FEATURES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

3. ELECTRICAL RATINGS . . . . . . . . . . . . . . . . . . . . 2

4. INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4.1. TOOLS REQUIRED . . . . . . . . . . . . . . . . . . . . . 3 4.2. LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4.3. REMOVAL OF OLD UNIT. . . . . . . . . . . . . . . . . 3 4.4. MOUNTING . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4.5. WIRING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4.5.1. TERMINAL DESCRIPTIONS . . . . . . . . . . . . . . 4 4.5.2. CONNECTING THE WIRES . . . . . . . . . . . . . . . 4 4.5.3. COMPLETING YOUR INSTALLATION . . . . . . . 4

5. OPERATING BASICS . . . . . . . . . . . . . . . . . . . 5 5.1. UP/DOWN CHANGE KEYS. . . . . . . . . . . . . . . . 5 5.2. SET DAY AND TIME . . . . . . . . . . . . . . . . . . . . 5 5.3. TEMPERATURE CONTROL MODES. . . . . . . . . 5 5.4. EMERGENCY (EMER) . . . . . . . . . . . . . . . . . . . 5 5.5. AUTOCHANGE (AUTO) . . . . . . . . . . . . . . . . . . 5 5.6. HEAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5.7. COOL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5.8. OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5.9. DEFAULT PROGRAM . . . . . . . . . . . . . . . . . . . 6 5.10. HOLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5.11. OVERRIDE. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5.12. FAN MODES . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5.12.1. AUTO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5.12.2. ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5.12.3. CLEAN CYCLE® . . . . . . . . . . . . . . . . . . . . . . . . 7 5.13. DISPLAY ILLUMINATION . . . . . . . . . . . . . . . . 7 5.14. AUDIBLE BEEP . . . . . . . . . . . . . . . . . . . . . . . . 7

6. PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . 7 6.1. DEFAULT TEMPERATURE PROGRAM . . . . . . . 7 6.2. EDITING HEAT OR COOL PROGRAMS . . . . . . 7 6.2.1. WEEKDAY PROGRAMMING . . . . . . . . . . . . . . 7 6.2.2. WEEKEND PROGRAMMING . . . . . . . . . . . . . . 8

6.3.CLEAN CYCLE®

(IAQ FAN PROGRAMMING) . . . . . . . . . . . . . . 8 6.4. COPY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

7. ADVANCED FEATURES . . . . . . . . . . . . . . . . . 9 7.1. KEYBOARD LOCK . . . . . . . . . . . . . . . . . . . . . . 9 7.2 FILTER MONITOR . . . . . . . . . . . . . . . . . . . . . . 9 7.2.1. FILTER USAGE . . . . . . . . . . . . . . . . . . . . . . . . 9 7.2.2. FILTER LIMIT . . . . . . . . . . . . . . . . . . . . . . . . . 9 7.3. ENERGY USAGE . . . . . . . . . . . . . . . . . . . . . . . 10 7.4. CALIBRATION OFFSET . . . . . . . . . . . . . . . . . . 10 7.5. RESET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 7.5.1. HARDWARE RESET . . . . . . . . . . . . . . . . . . . . 10 7.5.2. SOFTWARE RESET . . . . . . . . . . . . . . . . . . . . . 10 7.6. TEMPERATURE VARIATION / SWING . . . . . . . 10 7.6.1. SWING 1 – 1st STAGE . . . . . . . . . . . . . . . . . . 11 7.6.2. SWING 2 – 2nd STAGE . . . . . . . . . . . . . . . . . . 11 7.7. DEAD BAND . . . . . . . . . . . . . . . . . . . . . . . . . . 11

8. SET UP OPTIONS. . . . . . . . . . . . . . . . . . . . . . 11 8.1. MINIMUM RUN TIME – J3 . . . . . . . . . . . . . . . 12 8.2. CLOCK FORMAT – J4 . . . . . . . . . . . . . . . . . . . 12

8.3.TEMPERATURE DISPLAY FORMAT

(F/C DISPLAY) – J5. . . . . . . . . . . . . . . . . . . . . 12 8.4. SMART RECOVERY – J6. . . . . . . . . . . . . . . . . 12 8.5. FAN OVERRUN TIME – J7. . . . . . . . . . . . . . . . 12 8.6. REPOSITIONING JUMPERS . . . . . . . . . . . . . . 12

9. BATTERIES/MAINTENANCE . . . . . . . . . . . . . 12 9.1. BATTERY INSTALLATION . . . . . . . . . . . . . . . . 13

10. TECHNICAL ASSISTANCE . . . . . . . . . . . . . . . 13

11. WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . 13

12. WIRING DIAGRAMS. . . . . . . . . . . . . . . . . . . . 14

13. CROSS REFERENCE CHART . . . . . . . . . . . . . 15

14. USER PROGRAM TABLE . . . . . . . . . . . . . . . . 16

15. JUMPER TABLE. . . . . . . . . . . . . . . . . . . . . . . 16

WARNING: Use Energizer® or DURACELL®

Alkaline Batteries Only.

Energizer® is a registered trademark of Eveready Battery Company, Inc. DURACELL® is a registered trademark of The Gillette Company, Inc.

Mt. Laurel, New Jersey 08054, USA www.luxproproducts.com

52091

Image 1
Contents PSPHA732 Compatibility FeaturesElectrical Ratings Location Installation Tools RequiredRemoval of OLD Unit MountingAlso Refer to the Heat Pump Cross-reference Chart on WiringTape the ends of any unused wires Terminal DescriptionsSET DAY and Time Operating Basics UP/DOWN Change KeysEmergency Emer Autochange AutoOverride Default ProgramFAN Modes Set to HEAT, COOL, or Auto with the mode switch Clean CycleDisplay Illumination Audible BeepTime Weekend Programming600 AM 800 AMCopy Advanced Features Keyboard LockFilter Monitor Filter UsageHardware Reset ResetSoftware Reset Temperature Variation / SwingDead Band SET UP OptionsSmart Recovery J6 Temperature Display Format F/C Display J5Minimum RUN Time J3 Clock Format J4Re-hang it on its base plate as described in installation Battery InstallationTechnical Assistance Warranty Dashed wires are optional Wiring Diagram NotesCross Reference Chart for MULTI-STAGE Heat Pumps Mercury Warning and Recycling Notice User Program Table

PSPHA732 specifications

The Bryant PSPHA732 is a top-tier heat pump model designed to provide efficient heating and cooling solutions for residential and light commercial applications. Known for its impressive performance and reliability, this unit exemplifies modern HVAC technology, striking a perfect balance between comfort and efficiency.

One of the standout features of the Bryant PSPHA732 is its advanced variable-speed compressor, which allows for precise temperature control and exceptional energy efficiency. This technology enables the heat pump to operate at multiple speeds, adjusting seamlessly to the heating or cooling demand. As a result, homeowners can enjoy more consistent indoor temperatures while minimizing energy consumption, leading to significant savings on utility bills.

The PSPHA732 also boasts a high Seasonal Energy Efficiency Ratio (SEER) and Heating Seasonal Performance Factor (HSPF), making it one of the most efficient options in the market. With a SEER rating of up to 17 and an HSPF rating of up to 10, this unit qualifies for various energy-efficiency programs and tax credits, further enhancing its value proposition.

Another key characteristic of the Bryant PSPHA732 is its innovative design, which incorporates sound-dampening technology. This includes a specially designed fan and insulated compressor compartment, leading to quieter operation compared to traditional models. This is especially beneficial for homeowners seeking a peaceful indoor environment.

The unit’s durable construction is another highlight, featuring a weather-resistant cabinet designed to withstand harsh outdoor conditions. The galvanized steel exterior, combined with a factory-installed coat of paint, ensures long-lasting performance, protecting the unit from rust and corrosion.

Furthermore, the Bryant PSPHA732 is equipped with advanced controls and connectivity options. It is compatible with Bryant’s smart thermostat, allowing users to monitor and adjust their HVAC system remotely through a smartphone app. This integration not only enhances convenience but also optimizes energy use based on the homeowner's schedule and preferences.

Lastly, the PSPHA732 comes with a comprehensive warranty, providing peace of mind for users. With proper maintenance, this heat pump is designed to offer years of reliable service, making it a smart investment for those looking to enhance their home’s comfort and efficiency.

Overall, the Bryant PSPHA732 stands out as a leading choice in the heat pump market, combining cutting-edge technology, energy efficiency, and user-friendly features to deliver an exceptional climate control experience.