Bryant T2-PAC installation instructions Terminal Designations

Page 11

O/B - reversing valve

Y1 - Cooling

Low Stage

Rc - 24 VAC, from cooling equipment

Rh - 24 VAC, from heating equipment

W - Heating

C - Common 24 VAC

G - Fan

Y/Y2 - Cooling High or Single Stage

A09271

Fig. 3 - Terminal Designations

!CAUTION

ELECTRICAL OPERATION HAZARD

Failure to follow this caution may result in equipment damage or improper operation.

Improper wiring or installation may damage the thermostat. Check to make sure wiring is correct before proceeding with installation or turning on unit.

9.Push any excess wire into wall and against mounting base. Seal hole in wall to prevent air leaks. Leaks can affect operation.

10.Snap case back together. Attach thermostat to backplate by inserting tab on bottom edge and hinging up until top snap secures. See Fig. 4

9

Image 11
Contents Designed and Assembled in the U.S.A Legacy Series Programmable ThermostatPage Table of Contents Safety Considerations Introduction Models Installation ConsiderationsPower Thermostat Location Installation Environmental Hazard Backplate Mounting Secure Wires to Terminal Strip Terminal Designations Set Thermostat Configuration Configuration Options Summary Option 01 Equipment type Configuration Options SelectionTo Enter the Configuration Mode Option 10 Reversing valve Option 03 Fahrenheit/CentigradeOption 04 Fan G on with W output Option 07 ZoningOption 11 Minimum Deadband Between Heating And Cooling Option 12 Smart Recovery programmable model onlyOption 17 Minimum Time Between Equipment Stages Option 13 Room Air Temperature OffsetOption 15 Auto Changeover Availability Option 16 Maximum Cycles Per HourOption 21 Keypad Lockout Option 18 Backlight ConfigurationOption 27 Maximum Heating Setpoint Option 99 Reset to Factory DefaultsOption 26 Minimum Cooling Setpoint Check Thermostat Operation Checklist Display Lighting Features and AccessoriesBatteries Mounting Options Door SwitchRc/Rh Connections WiringTimers Operational and Connection InformationAuto Changeover Timer Error CodesMinimum On Timer Cycle TimerCool Heat EM Heat OutputsSingle Speed A/C Thermostat Typical Installation Wiring DiagramsWiring Diagrams Single-stage Furnace with Air Conditioner and Split Power Thermostat Heat Stage 3 furnace Heat/Cool Stage Fan 24VAC Hot Heating FV/FK Fan Coil w/2-Stage Air Conditioner FV/FK Fan Coil w/2-Stage Heat Pump Mode Settings Thermostat Configuration RecordConfiguration Options Page Page Page Page IIT2---PAC---05