Bryant T2-PAC installation instructions Installation Considerations, Models, Power

Page 6

INSTALLATION CONSIDERATIONS

Models

There are four models in the Legacy Series: programmable and non-programmable, AC and HP. Models T2-PAC and T2-NAC are designed for AC systems, controlling one stage of cooling and one stage of heating. They will not operate a heat pump. Models T2-PHP and T2-NHP are designed for HP systems, controlling two stages of cooling and three stages of heating. They can be converted to AC operation. Select the appropriate model for the intended application.

Power

All Legacy Series models are dual powered. They can operate from batteries or 24VAC power. Operation from 24VAC is preferred if available. Battery operation is used when there are not enough wires to support 24VAC operation or when “armchair programming” is desired. For an AC system, up to six wires are needed for 24VAC operation and one less wire for battery operation. For a HP system, up to seven wires are needed for 24VAC operation and and one less wire is sufficient for battery operation. For heat only operation with batteries, only two wires are required. When battery operation is used, the C terminal does not need to be connected.

Provision is also made for separate heating and cooling transformers via separable Rc and Rh terminals which are connected via factory-installed jumper wire.

4

Image 6
Contents Legacy Series Programmable Thermostat Designed and Assembled in the U.S.APage Table of Contents Safety Considerations Introduction Installation Considerations PowerModels Installation Thermostat LocationEnvironmental Hazard Backplate Mounting Secure Wires to Terminal Strip Terminal Designations Set Thermostat Configuration Configuration Options Summary Configuration Options Selection To Enter the Configuration ModeOption 01 Equipment type Option 07 Zoning Option 03 Fahrenheit/CentigradeOption 04 Fan G on with W output Option 10 Reversing valveOption 12 Smart Recovery programmable model only Option 11 Minimum Deadband Between Heating And CoolingOption 16 Maximum Cycles Per Hour Option 13 Room Air Temperature OffsetOption 15 Auto Changeover Availability Option 17 Minimum Time Between Equipment StagesOption 18 Backlight Configuration Option 21 Keypad LockoutOption 99 Reset to Factory Defaults Option 26 Minimum Cooling SetpointOption 27 Maximum Heating Setpoint Check Thermostat Operation Checklist Features and Accessories BatteriesDisplay Lighting Door Switch Mounting OptionsOperational and Connection Information WiringTimers Rc/Rh ConnectionsCycle Timer Error CodesMinimum On Timer Auto Changeover TimerOutputs Cool Heat EM HeatWiring Diagrams Single Speed A/C Thermostat Typical InstallationWiring Diagrams Single-stage Furnace with Air Conditioner and Split Power Thermostat Heat Stage 3 furnace Heat/Cool Stage Fan 24VAC Hot Heating FV/FK Fan Coil w/2-Stage Air Conditioner FV/FK Fan Coil w/2-Stage Heat Pump Thermostat Configuration Record Mode SettingsConfiguration Options Page Page Page Page IIT2---PAC---05