Bryant T2-PAC installation instructions Installation, Thermostat Location

Page 7

INSTALLATION

Step 1 — Thermostat Location

SApproximately 5 ft (1.5m) from floor.

SClose to or in a frequently used room, preferably on an inside partition- ing wall.

SOn a section of wall without pipes or duct work. Thermostat should NOT be mounted

SClose to a window, on an outside wall, or next to a door leading to the outside.

SExposed to direct light or heat from the sun, a lamp, fireplace, or other temperature-radiating objects which could cause a false reading.

SClose to or in direct airflow from supply registers and return-air re- gisters.

SIn areas with poor air circulation, such as behind a door or in an alcove.

Step 2 — Install Thermostat

!WARNING

ELECTRICAL OPERATION HAZARD

Failure to follow this warning could result in personal injury or death.

Before installing thermostat, turn off all power to equipment. There may be more than one power disconnect.

1.Turn OFF all power to unit.

2.If an existing thermostat is being replaced: a. Remove existing thermostat from wall.

5

Image 7
Contents Designed and Assembled in the U.S.A Legacy Series Programmable ThermostatPage Table of Contents Safety Considerations Introduction Power Installation ConsiderationsModels Thermostat Location InstallationEnvironmental Hazard Backplate Mounting Secure Wires to Terminal Strip Terminal Designations Set Thermostat Configuration Configuration Options Summary To Enter the Configuration Mode Configuration Options SelectionOption 01 Equipment type Option 10 Reversing valve Option 03 Fahrenheit/CentigradeOption 04 Fan G on with W output Option 07 ZoningOption 11 Minimum Deadband Between Heating And Cooling Option 12 Smart Recovery programmable model onlyOption 17 Minimum Time Between Equipment Stages Option 13 Room Air Temperature OffsetOption 15 Auto Changeover Availability Option 16 Maximum Cycles Per HourOption 21 Keypad Lockout Option 18 Backlight ConfigurationOption 26 Minimum Cooling Setpoint Option 99 Reset to Factory DefaultsOption 27 Maximum Heating Setpoint Check Thermostat Operation Checklist Batteries Features and AccessoriesDisplay Lighting Mounting Options Door SwitchRc/Rh Connections WiringTimers Operational and Connection InformationAuto Changeover Timer Error CodesMinimum On Timer Cycle TimerCool Heat EM Heat OutputsSingle Speed A/C Thermostat Typical Installation Wiring DiagramsWiring Diagrams Single-stage Furnace with Air Conditioner and Split Power Thermostat Heat Stage 3 furnace Heat/Cool Stage Fan 24VAC Hot Heating FV/FK Fan Coil w/2-Stage Air Conditioner FV/FK Fan Coil w/2-Stage Heat Pump Mode Settings Thermostat Configuration RecordConfiguration Options Page Page Page Page IIT2---PAC---05