Guardian Technologies ACT1000 ACTWinPro Configuration, ACT2000 Click here to Connect

Page 30

ACTWinPro Configuration

NETWORK

A B 0V

A

DOORS

0V

B

SERIAL/PRINTER

DTR

RX

 

TX

 

0V

 

GREEN

 

RED

 

ACT2000

Click here to Connect

Direct Connect Cable

ACTWinPro

From the Installer Menu, do the following:

1.Factory Default the controller.

2.Go to the Communications menu and Set Address. If there is only 1 controller, set the address to 1. For more than 1, assign each controller a unique address, starting at 1.

3.Set Direct Connect to Yes if the PC is connected directly to one controller (as shown above). Set to No if it is a networked system. For more than one controller, an RS-485 Network Interface is required.

4.Connect the controller(s) to the PC.

5.From ACTWinPro, configure a new database.

6.Follow the database creation wizard.

7.Ensure that Comms is set up correctly.

8.Connect to the controllers.

Click here to configure Comms

Select if Direct Connect or

Networked

Select COM port and Speed

Select if Serial Port or Modem or TCP/IP Connection

Page 27 of 32

Image 30
Contents Page Contents Communications Default Codes Menu Navigation KeysText Entry Keys Enable Card Validity2AUX output off User Setup Option DescriptionAssign PINs LearnBatch Cards One-To-One Group SetupAccess Rights Card Validity ACT 2000 OnlyTimezone At all times Door 23---7-AB C D E F G H + Full Access ? No Access ?System Log Auxiliary DoorPrint Log Wiring between Printer & Controller ControllerDisplay Log Filter Log ACT 2000 OnlyControl Door User Tracking ACT2000 OnlyClear All ACT2000 Only Set Date/TimeTime Zones Set Holidays C D E Assign Name ? Clear ?March Wed 1 Mar Holiday Issue Number Change PINSecond Door1 AlarmsOperation PIN Only Limiting2 One-To-OneLock Door Timers Relay TimeAjar Time PIN RequiredDisplay System SettingsOperation PIN LengthFire Doors User Tracking ACT2000 OnlyOutputs ACT2000 Only Door Settings AlarmsTimed Actions Action What HappensCommunications Card Setup Factory Default Site CodeCard Format Typical ACT1000 Configuration Standalone Typical ACT2000 Configuration Standalone DS100 Door Station Installation Always Place Varistor Across Lock TerminalsWiring for Entry/Exit Readers ControllerACT20 PIN Pad Installation Diagram Entry ReaderACT1000/2000 Cable Connections Interlock Configuration Fire Override ConfigurationDoor ACTWinPro Configuration ACT2000 Click here to ConnectACTWinPro ACT 4-Line Network Wiring To Mains SupplyTo PC RS-485 Bus 12V DC Power Supply 300mA +12VACT Single Line RS-485 Converter RS-232 ACTWin SoftwareACT Modem Configuration Direct Connection from Modem to ControllerActlan Configuration Diagram ACTWinPro SoftwareACT System Diagram ACTWinPro

ACT1000, ACT2000 specifications

Guardian Technologies, a leader in air purification solutions, offers two standout products in their lineup: the ACT2000 and the ACT1000. Both air purifiers leverage advanced technologies to deliver cleaner, fresher indoor air, making them ideal for families, pet owners, and anyone looking to improve their indoor air quality.

The ACT2000 is designed with a robust filtration system that includes a True HEPA filter capable of capturing 99.97% of airborne particles as small as 0.3 microns. This feature is particularly effective against allergens, dust, mold spores, and pet dander. Additionally, the ACT2000 employs an activated carbon filter that targets and neutralizes odors from cooking, pets, and smoke, ensuring that the air in your home remains fresh and pleasant.

A highlight of the ACT2000 is its innovative UV-C light technology. This feature works synergistically with the filtration system by using ultraviolet light to kill bacteria and viruses present in the air, creating a thorough air purification process. With its coverage of up to 1,250 square feet, the ACT2000 is suited for larger spaces such as living rooms, gyms, or open-concept homes. The device also comes equipped with real-time air quality monitoring, allowing users to track the air quality and adjust settings accordingly.

On the other hand, the ACT1000 is a more compact model, ideal for smaller rooms or offices up to 700 square feet. Similarly, it utilizes a True HEPA filter and an activated carbon filter to purify the air efficiently. While the ACT1000 may be smaller than its counterpart, it does not compromise on performance. The UV-C light technology is included to ensure that airborne pathogens are effectively neutralized.

Both models feature smart controls that allow users to operate the air purifiers remotely. With multiple fan speeds and a whisper-quiet operation, both units can run unobtrusively in the background, even while you’re sleeping or working. An intuitive filter replacement indicator alerts users when it’s time to change the filters, making maintenance simple and straightforward.

In summary, the Guardian Technologies ACT2000 and ACT1000 epitomize modern air purification with their combination of HEPA filtration, activated carbon, UV-C technology, and user-friendly features. Whether you choose the larger capacity of the ACT2000 or the compact efficiency of the ACT1000, both models offer an effective solution for creating a healthier indoor environment.