Guardian Technologies ACT2000 System Log, Timezone At all times Door 23---7-AB, Auxiliary Door

Page 9

ACT1000/2000 Operating Instructions

Software Version 3.23-00

3)Changing timezone

4)Changing door combination

Timezone

At all times

Door 7

[23---7—AB]

0for next timezone to select

0for next door

to select/deselect when done

In addition, Full Access or No Access may quickly be set for the group by highlighting and selecting the + or symbols respectively:

5)Setting Full Access

6)Setting No Access

A B C D E F G H + -

Full Access ?

A B C D E F G H + -

No Access ?

to set full access

to set no access

Assign Options

The Assign Options function allows additional options to be assigned collectively to all users in the group. The assigned options are displayed in brackets in the form [23TXB] with non- assigned options displayed as a dash. Pressing the key allows the options to be altered. When changing options, the 0 key advances to each option, and the key selects or deselects the displayed option.

Option

Description

2Activate O/P 2 The general-purpose output OP2 is activated for its programmed duration when users in this group are granted access.

3

Activate O/P 3

The general-purpose output OP3 is activated for its programmed

 

 

duration when users in this group are granted access.

T

Toggle Relay

When the user is granted access, the relay is toggled so the door

 

 

will remain permanently open until the next time the card or token

 

 

is read.

X

Auxiliary Door

On ACT1000 only, if the auxiliary door has been enabled, only

 

 

groups with this option selected are allowed access.

B

Track Bypass

On ACT2000 only, if tracking bypass is enabled, then users in this

 

 

group are always allowed access through antipassback doors.

Note: The options assigned to an individual user operate in addition to those assigned to the group.

Assign PINs

The Assign PINs function allows a different PIN to be assigned to each group of users. Initially, the PIN will be unset. Pressing the key will prompt for the PIN for the displayed group to be entered (it will not be displayed). The PIN must then be re-entered for verification. The PIN will be accepted as long as it does not conflict with any existing PIN (or duress PIN). The actual PIN is never shown on the display. If set, a PIN directly assigned to a user will take priority over this PIN.

System Log

The System Log menu allows the operator to view events in the historical event log, and to request a printout of the entire log.

Page 6 of 32

Image 9
Contents Page Contents Communications Default Codes Menu Navigation KeysText Entry Keys Enable Card Validity2AUX output off Option Description User SetupAssign PINs LearnBatch Cards Access Rights Group SetupOne-To-One Card Validity ACT 2000 OnlySystem Log C D E F G H + Full Access ? No Access ?Timezone At all times Door 23---7-AB Auxiliary DoorDisplay Log Wiring between Printer & Controller ControllerPrint Log Filter Log ACT 2000 OnlyUser Tracking ACT2000 Only Control DoorClear All ACT2000 Only Set Date/TimeTime Zones Set Holidays C D E Assign Name ? Clear ?March Wed 1 Mar Holiday Change PIN Issue NumberOperation PIN Only AlarmsSecond Door1 Limiting2 One-To-OneAjar Time Timers Relay TimeLock Door PIN RequiredOperation System SettingsDisplay PIN LengthFire Doors User Tracking ACT2000 OnlyOutputs ACT2000 Only Alarms Door SettingsTimed Actions Action What HappensCommunications Card Setup Factory Default Site CodeCard Format Typical ACT1000 Configuration Standalone Typical ACT2000 Configuration Standalone Always Place Varistor Across Lock Terminals DS100 Door Station InstallationController Wiring for Entry/Exit ReadersEntry Reader ACT20 PIN Pad Installation DiagramACT1000/2000 Cable Connections Interlock Configuration Fire Override ConfigurationDoor ACTWinPro Configuration ACT2000 Click here to ConnectACTWinPro ACT 4-Line Network Wiring To Mains SupplyTo PC ACT Single Line RS-485 Converter 12V DC Power Supply 300mA +12VRS-485 Bus RS-232 ACTWin SoftwareDirect Connection from Modem to Controller ACT Modem ConfigurationACTWinPro Software Actlan Configuration DiagramACTWinPro ACT System Diagram

ACT1000, ACT2000 specifications

Guardian Technologies, a leader in air purification solutions, offers two standout products in their lineup: the ACT2000 and the ACT1000. Both air purifiers leverage advanced technologies to deliver cleaner, fresher indoor air, making them ideal for families, pet owners, and anyone looking to improve their indoor air quality.

The ACT2000 is designed with a robust filtration system that includes a True HEPA filter capable of capturing 99.97% of airborne particles as small as 0.3 microns. This feature is particularly effective against allergens, dust, mold spores, and pet dander. Additionally, the ACT2000 employs an activated carbon filter that targets and neutralizes odors from cooking, pets, and smoke, ensuring that the air in your home remains fresh and pleasant.

A highlight of the ACT2000 is its innovative UV-C light technology. This feature works synergistically with the filtration system by using ultraviolet light to kill bacteria and viruses present in the air, creating a thorough air purification process. With its coverage of up to 1,250 square feet, the ACT2000 is suited for larger spaces such as living rooms, gyms, or open-concept homes. The device also comes equipped with real-time air quality monitoring, allowing users to track the air quality and adjust settings accordingly.

On the other hand, the ACT1000 is a more compact model, ideal for smaller rooms or offices up to 700 square feet. Similarly, it utilizes a True HEPA filter and an activated carbon filter to purify the air efficiently. While the ACT1000 may be smaller than its counterpart, it does not compromise on performance. The UV-C light technology is included to ensure that airborne pathogens are effectively neutralized.

Both models feature smart controls that allow users to operate the air purifiers remotely. With multiple fan speeds and a whisper-quiet operation, both units can run unobtrusively in the background, even while you’re sleeping or working. An intuitive filter replacement indicator alerts users when it’s time to change the filters, making maintenance simple and straightforward.

In summary, the Guardian Technologies ACT2000 and ACT1000 epitomize modern air purification with their combination of HEPA filtration, activated carbon, UV-C technology, and user-friendly features. Whether you choose the larger capacity of the ACT2000 or the compact efficiency of the ACT1000, both models offer an effective solution for creating a healthier indoor environment.