Guardian Technologies ACT2000, ACT1000 Enable, Card Validity2, AUX output off

Page 5

ACT1000/2000 Operating Instructions

Software Version 3.23-00

Operator Menu

 

User Setup

 

Enable

Allow a user or range of users to open the door

 

 

 

Disable

Prevent a user or range of users from opening the door

 

 

 

Assign Names

Enter a name for each user

 

 

 

Assign Groups

Assign users to groups

 

 

 

Assign Options

Specify options for each user

 

 

 

Assign PINs

Set the individual PIN for each user

 

 

 

Learn

Learn randomly coded cards (e.g. Bank Cards)

 

 

 

Batch Cards

Assign a batch of cards to a range of users

 

 

 

One-To-One

Assign a card to a user

 

 

 

Card Validity2

Set a validity period for a user.

 

Group Setup

 

 

Allow users in specified groups to open the door

 

 

Enable

 

 

 

Disable

Prevent users in specified groups from opening the door

 

 

 

Assign Names

Enter a name for each group

 

 

 

Access Rights

Specify what access rights apply to each group

 

 

 

Assign Options

Specify output and PIN options for each group

 

 

 

Assign PINs

Set the PIN for each Group.

 

System Log

 

 

Show the system log on the display (recent events first)

 

 

Display Log

 

 

 

Print Log

Print the system log on an attached serial printer

 

 

 

Filter Log2

Prevent events entering the system log

 

Control Door1

 

 

Lock door - prevent all cards from opening it.

 

 

Lock Door

 

 

 

Unlock Door

Unlock door - relay is activated so cards are not required.

 

 

 

Normalise Door

Set a door back to normal operation

 

 

 

Pass Door

Momentarily open a door for the programmed time

 

 

 

AUX output on

Switches the auxiliary output on

 

 

 

AUX output off

Switches the auxiliary output off

 

User Tracking2

 

 

Log a user into the tracking area

 

 

Log in

 

 

 

Log out

Log a user out of the tracking area

 

 

 

Clear All

Remove all users from the tracking area

 

Set Date/Time

 

Set the current date and time for the system

 

Time Zones

 

Specify the time periods and days which apply to a given timezone

 

Set Holidays

 

Specify which days within the next year are holidays

 

Issue Number

 

Set the current system issue level (if issue checking option enabled)

 

Change PIN

 

Change the PIN used to access the operator menu

Exit from the menu is automatic if no keys are pressed for a period of time. 1On the ACT2000, you will first be prompted for a door.

2Only present on ACT2000

Page 2 of 32

Image 5
Contents Page Contents Communications Text Entry Keys Default CodesMenu Navigation Keys AUX output off EnableCard Validity2 Option Description User SetupBatch Cards Assign PINsLearn Access Rights Group SetupOne-To-One Card Validity ACT 2000 OnlySystem Log C D E F G H + Full Access ? No Access ?Timezone At all times Door 23---7-AB Auxiliary DoorDisplay Log Wiring between Printer & Controller ControllerPrint Log Filter Log ACT 2000 OnlyUser Tracking ACT2000 Only Control DoorTime Zones Clear All ACT2000 OnlySet Date/Time March Wed 1 Mar Holiday Set HolidaysC D E Assign Name ? Clear ? Change PIN Issue NumberOperation PIN Only AlarmsSecond Door1 Limiting2 One-To-OneAjar Time Timers Relay TimeLock Door PIN RequiredOperation System SettingsDisplay PIN LengthOutputs ACT2000 Only Fire DoorsUser Tracking ACT2000 Only Alarms Door SettingsCommunications Timed ActionsAction What Happens Card Setup Card Format Factory DefaultSite Code Typical ACT1000 Configuration Standalone Typical ACT2000 Configuration Standalone Always Place Varistor Across Lock Terminals DS100 Door Station InstallationController Wiring for Entry/Exit ReadersEntry Reader ACT20 PIN Pad Installation DiagramACT1000/2000 Cable Connections Door Interlock ConfigurationFire Override Configuration ACTWinPro ACTWinPro ConfigurationACT2000 Click here to Connect To PC ACT 4-Line Network WiringTo Mains Supply ACT Single Line RS-485 Converter 12V DC Power Supply 300mA +12VRS-485 Bus RS-232 ACTWin SoftwareDirect Connection from Modem to Controller ACT Modem ConfigurationACTWinPro Software Actlan Configuration DiagramACTWinPro ACT System Diagram

ACT1000, ACT2000 specifications

Guardian Technologies, a leader in air purification solutions, offers two standout products in their lineup: the ACT2000 and the ACT1000. Both air purifiers leverage advanced technologies to deliver cleaner, fresher indoor air, making them ideal for families, pet owners, and anyone looking to improve their indoor air quality.

The ACT2000 is designed with a robust filtration system that includes a True HEPA filter capable of capturing 99.97% of airborne particles as small as 0.3 microns. This feature is particularly effective against allergens, dust, mold spores, and pet dander. Additionally, the ACT2000 employs an activated carbon filter that targets and neutralizes odors from cooking, pets, and smoke, ensuring that the air in your home remains fresh and pleasant.

A highlight of the ACT2000 is its innovative UV-C light technology. This feature works synergistically with the filtration system by using ultraviolet light to kill bacteria and viruses present in the air, creating a thorough air purification process. With its coverage of up to 1,250 square feet, the ACT2000 is suited for larger spaces such as living rooms, gyms, or open-concept homes. The device also comes equipped with real-time air quality monitoring, allowing users to track the air quality and adjust settings accordingly.

On the other hand, the ACT1000 is a more compact model, ideal for smaller rooms or offices up to 700 square feet. Similarly, it utilizes a True HEPA filter and an activated carbon filter to purify the air efficiently. While the ACT1000 may be smaller than its counterpart, it does not compromise on performance. The UV-C light technology is included to ensure that airborne pathogens are effectively neutralized.

Both models feature smart controls that allow users to operate the air purifiers remotely. With multiple fan speeds and a whisper-quiet operation, both units can run unobtrusively in the background, even while you’re sleeping or working. An intuitive filter replacement indicator alerts users when it’s time to change the filters, making maintenance simple and straightforward.

In summary, the Guardian Technologies ACT2000 and ACT1000 epitomize modern air purification with their combination of HEPA filtration, activated carbon, UV-C technology, and user-friendly features. Whether you choose the larger capacity of the ACT2000 or the compact efficiency of the ACT1000, both models offer an effective solution for creating a healthier indoor environment.