One-To-One

In One-To-One Mode, any known card may be assigned to any of the first 1000/2000 users. If the site code and card number are known then they may be entered in from the keypad or the card may also be presented to a reader (similar to Learn Mode).

Card Validity (ACT 2000 Only)

The Card Validity menu allows any of the first 2000 users to be assigned a validity period. A user is considered invalid if the current date is not within the validity dates.

Group Setup

The Group Setup menu allows the operator to control how the system handles groups of users. A group may be enabled or disabled as a block, and may have options and timezones applied to the group as a whole. Users 1 to 1000/20000 may be assigned to any of the 32 groups. Users numbered above 1000 on the ACT1000 always belong to the first group (unless programmed in blocks of 100 via ACTWinPro). Group selection is the same as for users: the group is selected by either using the 0 key to advance to the required group, or alternatively by using the numeric keys 1-9to directly enter the number of the desired group. The top line of the display will show the name for each group if one has been entered, otherwise the number only will be displayed.

Enable

The Enable function allows a group of users to be enabled. Pressing the key enables the displayed group. This means that the cards or tokens belonging to all users in the group will be recognized and will be allowed entry to the protected area provided that the individual users are also enabled.

Disable

The Disable function allows a group of users to be disabled. Pressing the key disables the displayed group. This means that the cards or tokens belonging to all the users in the group will no longer be recognized and will not be allowed entry to the protected area even if the individual users are enabled.

Assign Names

The Assign Names function allows a 16 character textual name to be assigned to each group. Pressing the key selects text entry mode. The group name is entered or deleted in exactly the same fashion as for individual user names.

Access Rights

The Access Rights function allows up to 8 timezone and door combinations to be specified for all users in a group. When a group is selected, the combinations will be displayed on the top line of the display in the form ABCDEFGH + -. The 0 key may be used to highlight one of these combinations and the bottom line of the display will show that timezone and door combination. Pressing the key allows the combination to be altered.

1)Select Group

2)Displaying access rights

Group 3

Timed Access

A B C D E F G H + -

At all times

Selected Doors

0for next group

to display access rights

0for next combination to change combination

Page 5 of 32

Image 8
Contents Page Contents Communications Text Entry Keys Default CodesMenu Navigation Keys AUX output off EnableCard Validity2 User Setup Option DescriptionBatch Cards Assign PINsLearn Group Setup Access RightsOne-To-One Card Validity ACT 2000 OnlyC D E F G H + Full Access ? No Access ? System LogTimezone At all times Door 23---7-AB Auxiliary DoorWiring between Printer & Controller Controller Display LogPrint Log Filter Log ACT 2000 OnlyControl Door User Tracking ACT2000 OnlyTime Zones Clear All ACT2000 OnlySet Date/Time March Wed 1 Mar Holiday Set HolidaysC D E Assign Name ? Clear ? Issue Number Change PINAlarms Operation PIN OnlySecond Door1 Limiting2 One-To-OneTimers Relay Time Ajar TimeLock Door PIN RequiredSystem Settings OperationDisplay PIN LengthOutputs ACT2000 Only Fire DoorsUser Tracking ACT2000 Only Door Settings AlarmsCommunications Timed ActionsAction What Happens Card Setup Card Format Factory DefaultSite Code Typical ACT1000 Configuration Standalone Typical ACT2000 Configuration Standalone DS100 Door Station Installation Always Place Varistor Across Lock TerminalsWiring for Entry/Exit Readers ControllerACT20 PIN Pad Installation Diagram Entry ReaderACT1000/2000 Cable Connections Door Interlock ConfigurationFire Override Configuration ACTWinPro ACTWinPro ConfigurationACT2000 Click here to Connect To PC ACT 4-Line Network WiringTo Mains Supply 12V DC Power Supply 300mA +12V ACT Single Line RS-485 ConverterRS-485 Bus RS-232 ACTWin SoftwareACT Modem Configuration Direct Connection from Modem to ControllerActlan Configuration Diagram ACTWinPro SoftwareACT System Diagram ACTWinPro

ACT1000, ACT2000 specifications

Guardian Technologies, a leader in air purification solutions, offers two standout products in their lineup: the ACT2000 and the ACT1000. Both air purifiers leverage advanced technologies to deliver cleaner, fresher indoor air, making them ideal for families, pet owners, and anyone looking to improve their indoor air quality.

The ACT2000 is designed with a robust filtration system that includes a True HEPA filter capable of capturing 99.97% of airborne particles as small as 0.3 microns. This feature is particularly effective against allergens, dust, mold spores, and pet dander. Additionally, the ACT2000 employs an activated carbon filter that targets and neutralizes odors from cooking, pets, and smoke, ensuring that the air in your home remains fresh and pleasant.

A highlight of the ACT2000 is its innovative UV-C light technology. This feature works synergistically with the filtration system by using ultraviolet light to kill bacteria and viruses present in the air, creating a thorough air purification process. With its coverage of up to 1,250 square feet, the ACT2000 is suited for larger spaces such as living rooms, gyms, or open-concept homes. The device also comes equipped with real-time air quality monitoring, allowing users to track the air quality and adjust settings accordingly.

On the other hand, the ACT1000 is a more compact model, ideal for smaller rooms or offices up to 700 square feet. Similarly, it utilizes a True HEPA filter and an activated carbon filter to purify the air efficiently. While the ACT1000 may be smaller than its counterpart, it does not compromise on performance. The UV-C light technology is included to ensure that airborne pathogens are effectively neutralized.

Both models feature smart controls that allow users to operate the air purifiers remotely. With multiple fan speeds and a whisper-quiet operation, both units can run unobtrusively in the background, even while you’re sleeping or working. An intuitive filter replacement indicator alerts users when it’s time to change the filters, making maintenance simple and straightforward.

In summary, the Guardian Technologies ACT2000 and ACT1000 epitomize modern air purification with their combination of HEPA filtration, activated carbon, UV-C technology, and user-friendly features. Whether you choose the larger capacity of the ACT2000 or the compact efficiency of the ACT1000, both models offer an effective solution for creating a healthier indoor environment.