Guardian Technologies ACT1000 ACT Single Line RS-485 Converter, 12V DC Power Supply 300mA +12V

Page 32

ACT Single Line RS-485 Converter

12V DC

 

Power

 

Supply

0V

 

(300mA) +12V

Pin

Function

 

 

1

+12V

2

0V & Shield

3

B

4

A

 

 

4 3 2 1

RS-485 Bus

19200

BAUDRATE

9600

SELECT

RS-232

ACTWin Software

Network cable is single shielded twisted pair: Belden 9501 or similar

To next Controller

NETWORK

A B 0V

ACT 2000

A

B 0V

DTR

RX

TX 0V

 

 

Battery

NETWORKPRINTER

A

 

 

0V

SERIAL/PRINTERDOORS

Timekeeper

 

B

Lithium

TX

 

 

 

 

 

 

RX

 

 

 

 

ACT 1000

RS485 line may be up to 1km in length and connect up to 32 controllers

 

NETWORK PRINTER

Shield

Timekeeper Lithium Battery

A

B

0V

TX

RX

 

ACT 1000

 

120R Resistor on last Controller.

Setup for Network Operation

1.From the Controller keypad Enter Installer Menu->Communications and set a unique address for each controller on the network. Set Direct Connect to No.

2.From ACTWinPro create a new database. In the database creation wizard check RS-485 Automatic Interface.

3.Connect to the controllers from ACTWinPro. The LED on the RS485 converter should blink rapidly indicating communications in progress.

Page 29 of 32

Image 32
Contents Page Contents Communications Text Entry Keys Default CodesMenu Navigation Keys AUX output off EnableCard Validity2 User Setup Option DescriptionBatch Cards Assign PINsLearn Group Setup Access RightsOne-To-One Card Validity ACT 2000 OnlyC D E F G H + Full Access ? No Access ? System LogTimezone At all times Door 23---7-AB Auxiliary DoorWiring between Printer & Controller Controller Display LogPrint Log Filter Log ACT 2000 OnlyControl Door User Tracking ACT2000 OnlyTime Zones Clear All ACT2000 OnlySet Date/Time March Wed 1 Mar Holiday Set HolidaysC D E Assign Name ? Clear ? Issue Number Change PINAlarms Operation PIN OnlySecond Door1 Limiting2 One-To-OneTimers Relay Time Ajar TimeLock Door PIN RequiredSystem Settings OperationDisplay PIN LengthOutputs ACT2000 Only Fire DoorsUser Tracking ACT2000 Only Door Settings AlarmsCommunications Timed ActionsAction What Happens Card Setup Card Format Factory DefaultSite Code Typical ACT1000 Configuration Standalone Typical ACT2000 Configuration Standalone DS100 Door Station Installation Always Place Varistor Across Lock TerminalsWiring for Entry/Exit Readers ControllerACT20 PIN Pad Installation Diagram Entry ReaderACT1000/2000 Cable Connections Door Interlock ConfigurationFire Override Configuration ACTWinPro ACTWinPro ConfigurationACT2000 Click here to Connect To PC ACT 4-Line Network WiringTo Mains Supply 12V DC Power Supply 300mA +12V ACT Single Line RS-485 ConverterRS-485 Bus RS-232 ACTWin SoftwareACT Modem Configuration Direct Connection from Modem to ControllerActlan Configuration Diagram ACTWinPro SoftwareACT System Diagram ACTWinPro

ACT1000, ACT2000 specifications

Guardian Technologies, a leader in air purification solutions, offers two standout products in their lineup: the ACT2000 and the ACT1000. Both air purifiers leverage advanced technologies to deliver cleaner, fresher indoor air, making them ideal for families, pet owners, and anyone looking to improve their indoor air quality.

The ACT2000 is designed with a robust filtration system that includes a True HEPA filter capable of capturing 99.97% of airborne particles as small as 0.3 microns. This feature is particularly effective against allergens, dust, mold spores, and pet dander. Additionally, the ACT2000 employs an activated carbon filter that targets and neutralizes odors from cooking, pets, and smoke, ensuring that the air in your home remains fresh and pleasant.

A highlight of the ACT2000 is its innovative UV-C light technology. This feature works synergistically with the filtration system by using ultraviolet light to kill bacteria and viruses present in the air, creating a thorough air purification process. With its coverage of up to 1,250 square feet, the ACT2000 is suited for larger spaces such as living rooms, gyms, or open-concept homes. The device also comes equipped with real-time air quality monitoring, allowing users to track the air quality and adjust settings accordingly.

On the other hand, the ACT1000 is a more compact model, ideal for smaller rooms or offices up to 700 square feet. Similarly, it utilizes a True HEPA filter and an activated carbon filter to purify the air efficiently. While the ACT1000 may be smaller than its counterpart, it does not compromise on performance. The UV-C light technology is included to ensure that airborne pathogens are effectively neutralized.

Both models feature smart controls that allow users to operate the air purifiers remotely. With multiple fan speeds and a whisper-quiet operation, both units can run unobtrusively in the background, even while you’re sleeping or working. An intuitive filter replacement indicator alerts users when it’s time to change the filters, making maintenance simple and straightforward.

In summary, the Guardian Technologies ACT2000 and ACT1000 epitomize modern air purification with their combination of HEPA filtration, activated carbon, UV-C technology, and user-friendly features. Whether you choose the larger capacity of the ACT2000 or the compact efficiency of the ACT1000, both models offer an effective solution for creating a healthier indoor environment.