Hearth and Home Technologies 21M-ACC Millennium Wood Stove ACC Service Parts & Accessories

Page 35

R

2100 Millennium Wood Stove (ACC)

B. Service Parts & Accessories

IMPORTANT: THIS IS DATED INFORMATION. When requesting a part for your appliance, please supply serial number and model name/number to ensure correct service parts. All parts may be order from an authorized dealer.

ITEM #

ACCESSORIES

PART NO.

 

Blower Assembly

BK-ACC

31

Door Assembly, Black

SRV7039-008

 

Outside Air Kit, Floor & Rear (termination cap, wire ties, flex adapter, fasteners)

OAK-ACC

see page 12

Outside Air Back Cover Plate & Sealing Rope, (1 inch x 4 ft) Floor Only

SRV7033-041

 

Upgrade to Nickel Door (includes Nickel Spring Handles (1) 1/2 inch and (2) 1/4

UK-DRNL

 

inch, (2) Nickel Hinge Pins and Nickel Quadra-Fire Logo

 

ITEM #

SERVICE PARTS

PART NO.

21

Air Channel, Convection

SRV7039-107

 

Air Control Rod Guide, Start-Up Air

7033-210

30

Baffle, Fiberboard (2 pieces) 8-1/8 in. wide x 13 in. high

SRV7039-111

 

Blower (Motor Only) Replacement

812-4900

29

Blanket, Ceramic 1/2 in. thick, field cut to size, 16-3/8 in. wide x 13 in. high

832-3390

 

Brick, Individual

832-0550

31

Brick Retainer

7033-149

27

Brick, Set

SRV7039-007

 

Brick, Uncut, (Set of 6)

832-3040

13

Burn Rate Air Control Assembly

7037-004

38

Cam Latch (Door Handle)

430-1141

 

Component Pack, (includes Touch-up Paint, Gold Spring Handles (1) 1/2 inch and

7039-011

 

(2) 1/4 inch, Trimount Plug, Owner’s Manual and Warranty Card

 

 

Component Pack for Nickel Door (includes Nickel Spring Handles (1) 1/2 inch and

436-5360

 

(2) 1/4 inch, (2) Nickel Hinge Pins and Nickel Quadra-Fire Logo

 

7

Control Arm Assembly, Rear Air

SRV7039-006

 

Door Handle Assembly

832-0540

34

Door Handle Rod Only

430-1131

24

Flue Collar

SRV7000-302

 

Gasket (Rope) Door, 3/4 inch x 7 ft, field cut to size

832-1680

 

Gasket, (Tape) Glass, 5 ft

832-0460

12

Gasket, Front & Rear Air Timer Doors

7033-282

36

Glass Assembly

7000-013

40

Glass Frame, Set (4 pc)

GL-FRM-21M

42

Hinge Pins, Gold (2)

832-0250

37

Key, Cam Latch, (Door Handle)

430-1151

4

Knob, Start-Up Air Control

7000-343

16

Label for Burn Rate Air Control

7033-160

17

Label for Start-Up Air Control

7033-166

 

Logo, Quadra-Fire, Gold

200-3180

 

Logo, Quadra-Fire, Nickel

200-3240

5

Magnet for Air Control

229-0631

September 1, 2008

7039-131F

Page 35

Image 35
Contents 7039-131F September 1 Hot glass will cause burnsMfg. Date 7039-131F September 1 Millennium Wood Stove ACCSerial No Model Name Table of Contents Mobile Home Approved Appliance Certification BTU & Efficiency SpecificationsGlass Specifications Listing and Code ApprovalsGetting Started Fire SafetyMillennium Wood Stove ACC Negative Pressure Appliance needs to draft properly for safetyInspect Appliance & Components Pre-Use Check List Millennium Wood Stove ACC Flue Draft ConsiderationsVenting Systems Tools And Supplies NeededMasonry Chimney Millennium Wood Stove ACC Typical Stove SystemsAppliance Dimensions Dimensions and ClearancesInstallation USA required Canada recommended InstallationRHearth Protection Requirements See FigureFloor Installation Alternative In some instances you Millennium Wood Stove ACC Outside Air Kit InstallationItems Needed for Installation not supplied Shock Risk Millennium Wood Stove ACC Blower OptionalThimble Chimney ConnectorChimney Requirements Venting Components Chimney SystemsSolid Pack Chimney with Metal Supports as a Thimble ComponentsAir Clearances InstructionsChimney Height / Rise and Run Installing Chimney ComponentsSingle wall connector or stove pipe Solid Pack Chimney with Metal Supports as a Thimble Cont’dPitched Roof Millennium Wood Stove ACC Chimney Termination RequirementsRule Mobile Home Installation Appliance Set-Up Door Handle Assembly Adjusting The Blower Speed ControlWood Selection & Storage Operating InstructionsOver-Firing Your Appliance Wood Selection & Storage Cont’d Burning ProcessAir Controls Automatic Combustion Control ACCBurn Rates and Operating Efficiency Millennium Wood Stove ACC Building a Fire Incorrect Positions Snap Disc Location Initial cold start-up and all Burn SettingsMillennium Wood Stove ACC Blower Operating Instructions Opacity SmokeAppliance Millennium Wood Stove ACC Frequently Asked QuestionsOdor from appliance Maintaining & Servicing Your Appliance General MaintenanceWhen cleaning glass Glass ReplacementMillennium Wood Stove ACC Firebrick Replacement Ceramic Blanket Correct Blanket & Baffle Position onReplacing Tube Channel Assembly Millennium Wood Stove ACC Tube Channel Assembly ReplacementRemoving Tube Channel Assembly Start Fire Problems Possible Cause Solution TroubleshootingExploded Drawings Reference MaterialsSizes Inch, 2 Nickel Hinge Pins and Nickel Quadra-Fire Logo Millennium Wood Stove ACC Service Parts & AccessoriesBlower Assembly RIVNUT-REPAIR Date of Service Performed By Description of Service Millennium Wood Stove ACC Service And Maintenance LogMillennium Wood Stove ACC Service And Maintenance Log Cont’d Millennium Wood Stove ACC Homeowner’s Notes Millennium Wood Stove ACC Homeowner’s Notes Cont’d CONDITIONS, Exclusions & Limitation of Liability 4021-645A This page is left blank intentionally Contact Information