Hearth and Home Technologies 21M-ACC warranty Mobile Home Installation

Page 18

2100 Millennium Wood Stove (ACC)

 

R

 

 

 

 

Mobile Home Installation

 

 

 

must use a Quadra-Fire Outside Air Kit Part

 

 

You6

 

 

 

OAK-ACC and (depending on floor installation, Part

 

Spark Arestor Cap

SRV7033-041) for installation in a mobile home.

 

 

 

1.

An outside air inlet must be provided for combustion See

 

 

 

page 12 for installation information.

Storm Collar

 

2.

Appliance must be secured to the mobile home structure

 

Roof Flashing

 

by bolting the pedestal through hearth pad and into

 

 

 

 

 

floor.

 

 

 

3.

Appliance must be grounded with #8 solid copper

 

 

 

grounding wire or equivalent and terminated at each end

Joist Shield/Firestop

 

 

with N.E.C. approved grounding device.

Double wall

 

 

 

 

4.

Appliance must be installed with an approved UL103 HT

 

connector pipe

 

ventilated chimney connector, UL103 HT chimney, and

 

 

 

terminal cap with spark arrestor. Never use a single wall

 

 

 

connector (stove pipe) in a mobile home installation. Use

 

 

 

only double-wall connector pipe, Dura-Vent DVL, Selkirk

 

 

 

metalbestos DS or Security DL double-wall connector or

 

 

 

any listed double-wall connector pipe.

 

 

5.

In Canada, this appliance must be connected to a 6 inch

 

Outside Air

 

(152mm) factory-built chimney conforming to CAN/ULC-

 

 

629M, STANDARD FOR FACTORY BUILT CHIMNEYS.

 

Rear Vent

 

 

 

6.

Follow the chimney and chimney connector manufacturer’s

Floor Protector

 

 

instructions when installing the flue system for use in a

 

 

mobile home.

 

 

7.

Maintain clearance to combustibles.

 

 

8.

Floor protection requirements must be followed

Outside Air Floor Vent

 

 

precisely.

 

9.

Use silicone to create an effective vapor barrier at the

Figure 18.1

 

 

location where the chimney or other component penetrates

 

 

to the exterior of the structure.

 

 

NOTE: Offsets from the vertical, not exceeding 45°, are

 

CAUTION

allowed per Section 905(a) of the Uniform Mechanical Code

(UMC). Offsets greater than 45° are considered horizontal

 

Maintain structural integrity of mobile home:

and are also allowed, providing the horizontal run does not

• Floor, wall, ceiling and/or roof.

exceed 75% of the vertical height of the vent. Construction,

clearance and termination must be in compliance with the

Do NOT cut through:

UMC Table 9C. This installation must also comply with NFPA

• Floor joist, wall, studs or ceiling trusses.

211.

• Any supporting material that would affect the structural

NOTE: Top sections of chimney must be removable to allow

integrity.

 

maximum clearance of 13.5 feet (411cm) from ground level

 

for transportation purposes.

 

 

10.

Burn wood only. Other types of fuels may generate

WARNING

 

poisonous gases (e.g., carbon monoxide).

Asphyxiation Risk.

11.

If unit burns poorly while an exhaust blower is on in

• Never install in a sleeping room.

 

home, (i.e., range hood), increase combustion air.

 

Consumes oxygen in the room.

 

 

12.Installation shall be in accordance with the Manufacturers Home & Safety Standard (HUD) CFR 3280, Part 24.

Page 18

7039-131F

September 1, 2008

Image 18
Contents Hot glass will cause burns 7039-131F September 1Millennium Wood Stove ACC Serial No Model NameMfg. Date 7039-131F September 1 Table of Contents Listing and Code Approvals Appliance Certification BTU & Efficiency SpecificationsGlass Specifications Mobile Home ApprovedFire Safety Getting StartedAppliance needs to draft properly for safety Millennium Wood Stove ACC Negative PressureTools And Supplies Needed Millennium Wood Stove ACC Flue Draft ConsiderationsVenting Systems Inspect Appliance & Components Pre-Use Check ListMillennium Wood Stove ACC Typical Stove Systems Masonry ChimneyDimensions and Clearances Appliance DimensionsInstallation See Figure InstallationRHearth Protection Requirements USA required Canada recommendedMillennium Wood Stove ACC Outside Air Kit Installation Items Needed for Installation not suppliedFloor Installation Alternative In some instances you Millennium Wood Stove ACC Blower Optional Shock RiskVenting Components Chimney Systems Chimney ConnectorChimney Requirements ThimbleInstructions ComponentsAir Clearances Solid Pack Chimney with Metal Supports as a ThimbleSolid Pack Chimney with Metal Supports as a Thimble Cont’d Installing Chimney ComponentsSingle wall connector or stove pipe Chimney Height / Rise and RunMillennium Wood Stove ACC Chimney Termination Requirements RulePitched Roof Mobile Home Installation Door Handle Assembly Adjusting The Blower Speed Control Appliance Set-UpBurning Process Operating InstructionsOver-Firing Your Appliance Wood Selection & Storage Cont’d Wood Selection & StorageAutomatic Combustion Control ACC Air ControlsBurn Rates and Operating Efficiency Millennium Wood Stove ACC Building a Fire Incorrect Positions Opacity Smoke Initial cold start-up and all Burn SettingsMillennium Wood Stove ACC Blower Operating Instructions Snap Disc LocationMillennium Wood Stove ACC Frequently Asked Questions Odor from applianceAppliance General Maintenance Maintaining & Servicing Your ApplianceGlass Replacement When cleaning glassMillennium Wood Stove ACC Firebrick Replacement Correct Blanket & Baffle Position on Ceramic BlanketMillennium Wood Stove ACC Tube Channel Assembly Replacement Removing Tube Channel AssemblyReplacing Tube Channel Assembly Troubleshooting Start Fire Problems Possible Cause SolutionReference Materials Exploded DrawingsSizes Millennium Wood Stove ACC Service Parts & Accessories Blower AssemblyInch, 2 Nickel Hinge Pins and Nickel Quadra-Fire Logo RIVNUT-REPAIR Millennium Wood Stove ACC Service And Maintenance Log Date of Service Performed By Description of ServiceMillennium Wood Stove ACC Service And Maintenance Log Cont’d Millennium Wood Stove ACC Homeowner’s Notes Millennium Wood Stove ACC Homeowner’s Notes Cont’d CONDITIONS, Exclusions & Limitation of Liability 4021-645A This page is left blank intentionally Contact Information

21M-ACC specifications

Hearth and Home Technologies' 21M-ACC model represents a significant advancement in the realm of modern home heating solutions. Designed for both aesthetic appeal and functional efficiency, this unit seamlessly integrates contemporary design with advanced technology.

The 21M-ACC is primarily known for its high efficiency, boasting an impressive thermal efficiency rating. This means less fuel is used to produce more heat, thereby reducing energy costs and consumption. One of the standout features is the high-efficiency combustion system that enhances the burning process, ensuring that the maximum amount of fuel is utilized before any emissions are released.

Another key characteristic of the 21M-ACC is its innovative AccuFire technology. This advanced control system allows users to finely adjust the flame height, heat output, and other parameters with precision. This level of customization not only enhances comfort but also contributes to energy savings. The model also features an easy-to-use digital control panel, enabling straightforward adjustments and monitoring of performance.

The design of the 21M-ACC is equally noteworthy. It showcases a sleek and stylish appearance that can complement various home décors, ranging from modern to rustic. The large viewing window provides an unobstructed view of the flames, creating a cozy ambiance while ensuring optimal heat distribution throughout the space.

Safety is paramount in the design of the 21M-ACC. It includes features such as a built-in safety shut-off system and a robust heat shield, which ensures that the exterior remains cool to the touch, making it safe for households with children or pets.

Additionally, this model is compatible with a variety of fuel types, including natural gas and propane, offering versatility for users. Whether utilizing it as a primary heat source or a supplementary feature, the 21M-ACC adapts to individual heating needs and preferences.

In conclusion, Hearth and Home Technologies' 21M-ACC combines efficiency, safety, and design sophistication, making it an exemplary choice for those looking to enhance their living space with a reliable heating solution.