Hearth and Home Technologies 21M-ACC Millennium Wood Stove ACC Tube Channel Assembly Replacement

Page 31

R

2100 Millennium Wood Stove (ACC)

F. Tube Channel Assembly Replacement

Removing Tube Channel Assembly

1.Remove the right side shield by removing 2 screws in the back using a Phillips head screw driver.

2.Remove 4 screws from channel access cover and remove cover.

3.Locate 2 channel nuts inside of chamber and remove using a 7/16 socket wrench. Slide out tube channel assembly.

NOTE:Soak the bolts with penetrating oil for at least 15 min- utes before trying to remove them.

Replacing Tube Channel Assembly

1.Slide one gasket on each tube first

2.Slide the tube channel assembly into side of firebox and insert each tube into the corresponding hole in the tube channel rack starting with the back hole first.

3.Make sure tube channel assembly is flush against the side of the stove and secure with channel nuts.

4.Re-install channel cover and side shield.

NOTE: Service Space

In order to replace the tube channel assembly a clear- ance of 17 inches (432mm) is required on the right side of stove in order to remove the tubes with the stove in place.

If space is not available, the stove will have to be dis- connected from the chimney to proceed with the tube replacement.

 

Slide one gasket

 

 

Tube Channel Rack

over each tube

Channel

 

 

Channel Cover

 

 

Access

 

 

Cover

Screws (4)

Remove

Channel2 Screws

Nuts (2)

Tube Channel

Assembly

Side Panel

Figure 31.1

September 1, 2008

7039-131F

Page 31

Image 31
Contents 7039-131F September 1 Hot glass will cause burnsSerial No Model Name Millennium Wood Stove ACCMfg. Date 7039-131F September 1 Table of Contents Mobile Home Approved Appliance Certification BTU & Efficiency SpecificationsGlass Specifications Listing and Code ApprovalsGetting Started Fire SafetyMillennium Wood Stove ACC Negative Pressure Appliance needs to draft properly for safetyInspect Appliance & Components Pre-Use Check List Millennium Wood Stove ACC Flue Draft ConsiderationsVenting Systems Tools And Supplies NeededMasonry Chimney Millennium Wood Stove ACC Typical Stove SystemsAppliance Dimensions Dimensions and ClearancesInstallation USA required Canada recommended InstallationRHearth Protection Requirements See FigureItems Needed for Installation not supplied Millennium Wood Stove ACC Outside Air Kit InstallationFloor Installation Alternative In some instances you Shock Risk Millennium Wood Stove ACC Blower OptionalThimble Chimney ConnectorChimney Requirements Venting Components Chimney SystemsSolid Pack Chimney with Metal Supports as a Thimble ComponentsAir Clearances InstructionsChimney Height / Rise and Run Installing Chimney ComponentsSingle wall connector or stove pipe Solid Pack Chimney with Metal Supports as a Thimble Cont’dRule Millennium Wood Stove ACC Chimney Termination RequirementsPitched Roof Mobile Home Installation Appliance Set-Up Door Handle Assembly Adjusting The Blower Speed ControlWood Selection & Storage Operating InstructionsOver-Firing Your Appliance Wood Selection & Storage Cont’d Burning ProcessAir Controls Automatic Combustion Control ACCBurn Rates and Operating Efficiency Millennium Wood Stove ACC Building a Fire Incorrect Positions Snap Disc Location Initial cold start-up and all Burn SettingsMillennium Wood Stove ACC Blower Operating Instructions Opacity SmokeOdor from appliance Millennium Wood Stove ACC Frequently Asked QuestionsAppliance Maintaining & Servicing Your Appliance General Maintenance When cleaning glass Glass ReplacementMillennium Wood Stove ACC Firebrick Replacement Ceramic Blanket Correct Blanket & Baffle Position onRemoving Tube Channel Assembly Millennium Wood Stove ACC Tube Channel Assembly ReplacementReplacing Tube Channel Assembly Start Fire Problems Possible Cause Solution TroubleshootingExploded Drawings Reference MaterialsSizes Blower Assembly Millennium Wood Stove ACC Service Parts & AccessoriesInch, 2 Nickel Hinge Pins and Nickel Quadra-Fire Logo RIVNUT-REPAIR Date of Service Performed By Description of Service Millennium Wood Stove ACC Service And Maintenance LogMillennium Wood Stove ACC Service And Maintenance Log Cont’d Millennium Wood Stove ACC Homeowner’s Notes Millennium Wood Stove ACC Homeowner’s Notes Cont’d CONDITIONS, Exclusions & Limitation of Liability 4021-645A This page is left blank intentionally Contact Information