Hearth and Home Technologies 21M-ACC warranty Millennium Wood Stove ACC Flue Draft Considerations

Page 7

R

2100 Millennium Wood Stove (ACC)

D. Flue Draft Considerations

Location of the appliance and chimney will affect perfor- mance. As shown in Figure 6.1 on page 6 the chimney should:

Be installed through the warm space enclosed by the building envelope. This helps to produce more draft, especially during lighting and die down of the fire.

Penetrate the highest part of the roof. This minimizes the affects of wind turbulence and down drafts.

Consider the appliance location in order to avoid floor and ceiling attic joists and rafters.

Exterior conditions such as roof line, surrounding trees, prevailing winds and nearby hills can influence stove performance. Your local dealer is the expert in your geographic area and can usually make suggestions or discover solutions that will easily correct your flue problem.

To be sure that your appliance burns properly, the chimney draft (static pressure) should be approximately -.04 inch water column (W.C.) during a low burn and -.10 inch W.C. during a high burn, measured 6 inches (152mm) above the top of the appliance after one hour of operation at each burn setting.

NOTE: These are guidelines only, and may vary somewhat for individual installations.

E. Venting Systems

The venting system consists of a chimney connector (also known as stove pipe) and a chimney. These get extremely hot during use. Temperatures inside the chimney may exceed 2000°F (1100°C) in the event of a creosote fire. To protect against the possibility of a house fire, the chimney connector and chimney must be properly installed and maintained. An approved thimble must be used when a connection is made through a combustible wall to a chimney. A chimney support package must be used when a connection is made through the ceiling to a prefabricated chimney. These accessories are absolutely necessary to provide safe clearances to combustible wall and ceiling material. Follow venting manufacturer’s clearances when installing venting system.

F. Tools And Supplies Needed

Before beginning the installation be sure that the following tools and building supplies are available.

Reciprocating saw

Framing Material

Pliers

Hi-Temp Caulking Material

Hammer

Gloves

Phillips Head Screwdriver

Framing Square

Flat Blade Screwdriver

Electric Drill & Bits (1/4”)

Plumb Line

Safety Glasses

Level

1/2 in. - 3/4 in. length, #6 or

Tape Measure

#8 self drilling screws (need 3

 

per pipe section connection)

 

 

G. Inspect Appliance & Components and

Pre-Use Check List

1.

 

Place the appliance in a location near the final

 

 

installation area and follow the procedures below:

2.

 

Open the appliance and remove all the parts and

 

 

articles packed inside the Component Pack. Inspect

 

 

all the parts and glass for shipping damage. Contact

 

 

your dealer if any irregularities are noticed.

3.

 

All safety warnings have been read and followed.

4.

 

This Owner’s Manual has been read.

5.

 

Floor protection requirements have been met.

6.

 

Venting is properly installed.

7.

 

The proper clearances from the appliance and chim-

 

 

ney to combustible materials have been met.

8.

 

The masonry chimney is inspected by a professional

 

 

and is clean, or the factory built metal chimney is

 

 

installed according to the manufacturer’s instruc-

 

 

tions and clearances.

9.

 

The chimney meets the required minimum height.

10.

 

All labels have been removed from the glass door.

11.

 

A power outlet is available nearby if installing

 

 

optional blower assembly.

WARNING

Asphyxiation Risk.

Do NOT connect this unit to a chimney flue servicing another appliance.

Do NOT connect to any air distributon duct or system.

May allow flue gases to enter the house.

WARNING

Fire Risk.

Inspect appliance and components for damage. Damaged parts may impair safe operation.

Do NOT install damaged components.

Do NOT install incomplete components.

Do NOT install substitute components.

Report damaged parts to dealer.

September 1, 2008

7039-131F

Page

Image 7
Contents 7039-131F September 1 Hot glass will cause burnsSerial No Model Name Millennium Wood Stove ACCMfg. Date 7039-131F September 1 Table of Contents Mobile Home Approved Appliance Certification BTU & Efficiency SpecificationsGlass Specifications Listing and Code ApprovalsGetting Started Fire SafetyMillennium Wood Stove ACC Negative Pressure Appliance needs to draft properly for safetyInspect Appliance & Components Pre-Use Check List Millennium Wood Stove ACC Flue Draft ConsiderationsVenting Systems Tools And Supplies NeededMasonry Chimney Millennium Wood Stove ACC Typical Stove SystemsAppliance Dimensions Dimensions and ClearancesInstallation USA required Canada recommended InstallationRHearth Protection Requirements See FigureItems Needed for Installation not supplied Millennium Wood Stove ACC Outside Air Kit InstallationFloor Installation Alternative In some instances you Shock Risk Millennium Wood Stove ACC Blower OptionalThimble Chimney ConnectorChimney Requirements Venting Components Chimney SystemsSolid Pack Chimney with Metal Supports as a Thimble ComponentsAir Clearances InstructionsChimney Height / Rise and Run Installing Chimney ComponentsSingle wall connector or stove pipe Solid Pack Chimney with Metal Supports as a Thimble Cont’dRule Millennium Wood Stove ACC Chimney Termination RequirementsPitched Roof Mobile Home Installation Appliance Set-Up Door Handle Assembly Adjusting The Blower Speed ControlWood Selection & Storage Operating InstructionsOver-Firing Your Appliance Wood Selection & Storage Cont’d Burning ProcessAir Controls Automatic Combustion Control ACCBurn Rates and Operating Efficiency Millennium Wood Stove ACC Building a Fire Incorrect Positions Snap Disc Location Initial cold start-up and all Burn SettingsMillennium Wood Stove ACC Blower Operating Instructions Opacity SmokeOdor from appliance Millennium Wood Stove ACC Frequently Asked QuestionsAppliance Maintaining & Servicing Your Appliance General MaintenanceWhen cleaning glass Glass ReplacementMillennium Wood Stove ACC Firebrick Replacement Ceramic Blanket Correct Blanket & Baffle Position onRemoving Tube Channel Assembly Millennium Wood Stove ACC Tube Channel Assembly ReplacementReplacing Tube Channel Assembly Start Fire Problems Possible Cause Solution TroubleshootingExploded Drawings Reference MaterialsSizes Blower Assembly Millennium Wood Stove ACC Service Parts & AccessoriesInch, 2 Nickel Hinge Pins and Nickel Quadra-Fire Logo RIVNUT-REPAIR Date of Service Performed By Description of Service Millennium Wood Stove ACC Service And Maintenance LogMillennium Wood Stove ACC Service And Maintenance Log Cont’d Millennium Wood Stove ACC Homeowner’s Notes Millennium Wood Stove ACC Homeowner’s Notes Cont’d CONDITIONS, Exclusions & Limitation of Liability 4021-645A This page is left blank intentionally Contact Information

21M-ACC specifications

Hearth and Home Technologies' 21M-ACC model represents a significant advancement in the realm of modern home heating solutions. Designed for both aesthetic appeal and functional efficiency, this unit seamlessly integrates contemporary design with advanced technology.

The 21M-ACC is primarily known for its high efficiency, boasting an impressive thermal efficiency rating. This means less fuel is used to produce more heat, thereby reducing energy costs and consumption. One of the standout features is the high-efficiency combustion system that enhances the burning process, ensuring that the maximum amount of fuel is utilized before any emissions are released.

Another key characteristic of the 21M-ACC is its innovative AccuFire technology. This advanced control system allows users to finely adjust the flame height, heat output, and other parameters with precision. This level of customization not only enhances comfort but also contributes to energy savings. The model also features an easy-to-use digital control panel, enabling straightforward adjustments and monitoring of performance.

The design of the 21M-ACC is equally noteworthy. It showcases a sleek and stylish appearance that can complement various home décors, ranging from modern to rustic. The large viewing window provides an unobstructed view of the flames, creating a cozy ambiance while ensuring optimal heat distribution throughout the space.

Safety is paramount in the design of the 21M-ACC. It includes features such as a built-in safety shut-off system and a robust heat shield, which ensures that the exterior remains cool to the touch, making it safe for households with children or pets.

Additionally, this model is compatible with a variety of fuel types, including natural gas and propane, offering versatility for users. Whether utilizing it as a primary heat source or a supplementary feature, the 21M-ACC adapts to individual heating needs and preferences.

In conclusion, Hearth and Home Technologies' 21M-ACC combines efficiency, safety, and design sophistication, making it an exemplary choice for those looking to enhance their living space with a reliable heating solution.