LG Electronics LT0810CR, LT1210CR, LT1010CR Procedure C, Remove the backing from the Horizontal

Page 16

Installation

PROCEDURE C

1 Redirect the louvers at the back of the wall sleeve to 60° angle as shown in the FIG 14. The use of pliers is recommended.

 

7 3/32"

60°

60°

 

Rear Louvers

 

(Top View)

 

FIG. 14

2

If the wall sleeve already has a rear grille, skip

 

to step 4. If the wall sleeve does not have a rear

grille or louvered panel, install the plastic grille from the kit. Cut the plastic grille to 26-1/2" wide and 15-1/2" high. Place the plastic grille to the inside of the wall sleeve at the rear flange.

4

Remove the backing from the Horizontal

 

Insulation strip 237/32 x 13/8 x 13/16 and attach

that to the inside right of the sleeve as shown below. Remove the backing from the Around Insulation strip 5927/32 x 13/8 x 13/8 and attach that to the inside front of the sleeve as shown below.

Indoor

Outdoor

Around Insulation

 

Horizontal Insulation

 

8 1/2"

 

 

FIG. 17

5

If the depth of your existing sleeve is less than

 

or equal to 18”, skip to step 7. Otherwise, cut

the baffles and the support blocks according to Length "A" in the table below.

Place the plastic grilleFIG. 15

Depth"D" of the existing

Length "A"

wall sleeve (inches)

(inches)

 

 

 

18 D

18-5/8

3/4

18-5/8

D 19-3/4

1-3/4

19-3/4

D 22

4

 

 

 

A

Support

Block

Baffle

A FIG. 18

3 Fasten the 4 washer screws to secure the grille to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges.

 

or

Fasten the screws

FIG. 16

6

Remove the backing from the support blocks

 

and attach them to the inside of the wall sleeve

as shown FIG 19. Slide the baffle into slots of the support blocks

Wall

(7 3/32")

 

Wall

Baffle

Sleeve

 

Front

Support

 

Block

 

FIG. 19

16Room Air Conditioner

Image 16
Contents Room AIR Conditioner Table of Contents Safety Precautions Don’t use a power cord, a Always plug into a groundedOutlet Power cord length Is damaged Be caution when unpacking and installingUnplug the unit if strange Sounds, odors, or smokeCome from it During operation Ventilate the room well whenHold the plug by the head When gas leaks, open Keep level parallel in installing the productOtherwise, it may cause vibration or water leakage It will cause electric shock or fireSharp edges when Perform ventilation Installing Sometimes Do not block the inlet or outlet of air flowDo not step on Always insert the filter Be cautious not to touchCleaning and Maintenance ServiceBefore Operation Preparing for OperationFeatures Symbols Used in this ManualIntroduction Electrical Safety Use Wall Receptacle Power SupplyElectrical Data Wash hands after handlingElectrical Safety Please Read CarefullyInstallation Requirements InstallationMake sure air conditioner does not fall during installation Installation HOW to Install Procedure a Supplied with your unit,skip to step To the wall sleeve. If you need plastic nuts to Trim 2 eaTop View Procedure BFasten the screws Procedure a WallRemove the backing from the Horizontal Procedure CRemove the backing from the support blocks To achieve rearward slope for unit draining Remove the backing from the 1113/16 shimOperating Instructions ControlsIncrements of 1 F Remote controlFAN Fan-only operation Ventilation How to insert BatteriesAir Direction Air Filter Cleaning Maintenance and ServiceHow to Attach Front Grille to Cabinet Troubleshooting Common Problems and SolutionsNormal Operation Memo Modelo n Serie n Escriba aquí el modelo y número de serieNombre del distribuidor Fecha de compra Precauciones de Seguridad Toma a tierraNo desmonte ni modifique Tenga cuidado al Los productos AparatoNo ponga el cable de alimentación cerca de un calentador Sostenga el enchufe por su cabeza al sacarlo No dañe ni use un enchufe de alimentación no especificadoMantenga nivelado el producto al instalarlo No se suba a la unidad Inserte siempre el filtro Puntiagudos al instalar Ocasiones Del aire durante elPreparación para el funcionamiento UsoLimpieza y mantenimiento ServicioSímbolos Utilizados en Este Manual IntroducciónCaracterísticas Seguraida Electrica Datos ElectricosSeguraida Electrica Importante Favorlea CON AtenciónInstalacion Requisitos DE InstalaciónPeríodo de tiempo Frontal y posteriorInstalación Cómo InstalarProcedimiento a ParedProcedimiento B Perspectiva superiorColoque la rejilla plástica Apriete los tornillosAjuste la posición según describe el paso Procedimiento aProcedimiento C Igual a 18, salte al paso 7. Si no, corte lasDel soporte de pared Drenaje de la unidad, retire el envoltorio de lasInstruccionnes de Funcionamiento ControlesEl ajuste se muestra en pantalla Del ventilador, control de temperatura en 72 FControl remoto Reinicio automáticoIncrementos de 1 F El ajuste aparece en pantallaVentilación Cómo Poner Las BateriasDirección del aire Limpieza del filtro de aire Cuidado y MantenimientoComo agregar la rejilla frontal al gabinete Problemas y soluciones habituales Operación normalOperación anormal Gire el control de Temperatura a un número más bajoNota Nota Aire Acondicionador Garantía Limitada DEL Aire Acondicionador LG EE.UU LG Room AIR Conditioner Limited Warranty USA Patent No. Us 6, 412 No A20437P