LG Electronics 3828A20025V Installation of Unit, Selection of the best location

Page 6

Installation of Unit

Installation of Unit

Selectionof the bestlocation

1.Indoor unit

There should not be any heat source or steam near the unit.

There should not be any obstacles to prevent the air circulation.

A place where air circulation in the room will be good.

A place where drainage can be easily obtained.

A place where noise prevention is taken into consideration.

Do not install the unit near the door way.

Ensure the spaces indicated by arrows from the wall, ceiling, or other obstacles.

The indoor unit must keep the maintenance space.

40cm 100cm

5cm 40cm

2.Outdoor unit

If an awning is built over the unit to prevent direct sunlight or rain exposure, be careful that heat radiation from the condenser is not restricted.

There should not be any animals or plants which could be affected by hot air discharged.

Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.

 

Sunroof

More than

 

50cm

 

Fence

More than

350cm

 

or

 

obstacles

More than 50cm

 

 

More than 100cm

6Floor Standing type Air Conditioner

Image 6
Contents LG Floor Standing Type Air Conditioner Table of Contents Always ground the product Use the correctly rated breaker or fuseBe sure the installation area does not deteriorate with age OperationKeep level even when installing the product Use two or more people to lift and transport the productInstallation of Unit Selection of the best locationPiping length and the elevation Indoor Unit Installation Outdoor unit InstallationRefrigerant amount Installation guide at the seaside Selecting the locationOutdoor UnitInstallation Method Installation works DescriptionsPreparation of installation parts and tools Installation Parts, Tools UsePreparation of Piping Cut the pipes and the cablePrecautions in bending Connection of pipingMove the indoor tubing and drain hose to the hole Connecting the Cable to Indoor Unit Connecting pipings to the outdoor unit Connecting the cables to the outdoor unitPower Supply and Wiring Power supplyVacuum Drying of the Connecting Pipes and the Indoor Unit Form the Piping Final Check and Test Run Memo Floor Standing type Air Conditioner