LG Electronics 3828A20025V Installation guide at the seaside, Selecting the locationOutdoor Unit

Page 9

Installation of Unit

Installationguideat the seaside

CAUTION

1.Air conditioners should not be installed in areas where corrosive gases, such as acid or alkaline gas, are produced.

2.Do not install the product where it could be exposed to sea wind (salty wind) directly. It can result corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunc- tion or inefficient performance.

3.If outdoor unit is installed close to the seaside, it should avoid direct exposure to the sea wind. Otherwise it needs additional anticorrosion treatment on the heat exchanger.

Selecting the location(Outdoor Unit)

1.If the outdoor unit is to be installed close to the seaside, direct exposure to the sea wind should be avoided. Install the outdoor unit on the opposite side of the sea wind direction.

Sea wind

Sea wind

2. In case, to install the outdoor unit on the seaside, set up a windbreak not to be exposed to the sea wind.

Windbreak

Sea wind

3. Select a well-drained place.

It should be strong enough like concrete to prevent the sea wind from the sea.

The height and width should be more than 150% of the outdoor unit.

It should be keep more than 70 cm of space between outdoor unit and the windbreak for easy air flow.

1.If you can’t meet above guide line in the seaside installation, please contact LG Electronics for the additional anticorrosion treatment.

2.Periodic ( more than once/year ) cleaning of the dust or salt particles stuck on the heat exchanger by using water

Installation Manual 9

Image 9
Contents LG Floor Standing Type Air Conditioner Table of Contents Use the correctly rated breaker or fuse Always ground the productOperation Be sure the installation area does not deteriorate with ageUse two or more people to lift and transport the product Keep level even when installing the productSelection of the best location Installation of UnitPiping length and the elevation Indoor Unit Installation Outdoor unit InstallationRefrigerant amount Selecting the locationOutdoor Unit Installation guide at the seasideInstallation works Descriptions Installation MethodInstallation Parts, Tools Use Preparation of installation parts and toolsCut the pipes and the cable Preparation of PipingPrecautions in bending Connection of pipingMove the indoor tubing and drain hose to the hole Connecting the Cable to Indoor Unit Connecting the cables to the outdoor unit Connecting pipings to the outdoor unitPower supply Power Supply and WiringVacuum Drying of the Connecting Pipes and the Indoor Unit Form the Piping Final Check and Test Run Memo Floor Standing type Air Conditioner