LG Electronics MP03-VDLPM installation instructions Table of Contents

Page 2

2

TABLE OF CONTENTS

 

 

Packaging

page

2

Introduction

page

2

General Information

page

2

Location

..........................................

page

4

Appliance and Vent Clearances

page

5

Requirements for Commonwealth

 

 

of Massachusetts

page

5

Vent Termination Clearances

page

5

Typical Installation Sequence

page

6

Detailed Installation Steps

page

6

Step 1.

Framing

page

6

Step 2. Routing Gas Line

page

6

Fireplace Specifications

page

9

Step 3. Install the Vent System

page

10

Vertical Termination Systems

page

10

Vent Section Length Chart

page

11

Vertical Vent Tables and Figures

page

14

Horizontal Termination System

page

15

Horizontal Vent Tables and Figures . page

18

Venting Using Flexible Vent Pipe

page

21

Step 4.

Field Wiring

page

22

Step 5. Connecting Gas Line

page

23

Step 6.

Installing Logs

page

24

Step 7.

Checking Unit Operation

page

24

Step 8. Installing Glass Door

page

24

Step 9.

Burner Adjustments

page

25

Finishing Requirements

page

25

Cold Climate Insulation

page

26

Installation Accessories

page

26

Gas Conversion Kits

page 28

This manual is part of a set of three support- ing this product. Refer to manuals 875,036M for Care & Operations and 750,230M for Log Placement Guide.

Please read and understand these instructions before beginning your installation.

PACKAGING

The assembled vented gas fireplace heater is packaged with the folowing:

1 - The logs are packaged in a carton located within the firebox.

2- One bag of volcanic stones is located in the bottom compartment.

3- One envelope containing the litera- ture package, which consists of the homeowner's manual, installation in- structions, log set supplement, warranty, gas access plate, screws (4) and gasket. The envelope is located in the bottom compartment.

4- One vent restrictor, to be used as detailed on page 10.

5- One hood and one control compartment cover and one 45 degree starter elbow are strapped to the top of the unit.

INTRODUCTION

These fireplaces are designed, tested and listed for operation and installation with, and only with, Secure Vent™ Direct Vent System Components, Secure Flex™ Flexible Vent Components manu- factured by Security Chimneys International and Z-Flex Model GA Venting Systems, listed to UL1777 and ULCS635 manufactured by Flex- master Canada Limited. These approved vent system components are labeled for identifica- tion. DO NOT use any other manufacturer's vent components with these appliances.

Millivolt appliances are designed to operate on natural or propane gas. A millivolt gas control valve with piezo ignition system pro- vides safe, efficient operation. There is no optional blower with these units.

Electronic appliances are designed to operate on natural or propane gas. An electronic inter- mittent pilot ignition system provides safe, ef- ficient operation. External electrical power is recommended to operate these units. If the system operates on line voltage with 3V adapt- ers, two (2) "D" batteries can be used as a backup in case of a power outage. The elec- tronic appliance can be operated solely with two

(2) "D batteries.

These appliances comply with National Safety Standards and are tested and listed by Omni- Test Laboratories (Report No. 116-F-47-5) to ANSI Z21.88 (in Canada, CSA-2.33), and CAN/ CGA-2.17-M91 in both USA and Canada, as vented gas fireplace heaters.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Both millivolt and electronic versions of these appliances are listed by Omni-Test Labora- tories for installation in bedrooms and mo- bile homes.

The Installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installa- tion Code, CSA B149.1.

The appliance, when installed, must be elec- trically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT.

GENERAL INFORMATION

Note: Installation and repair should be per- formed by a qualified service person. The appli- ance should be inspected annually by a qualified professional service technician. More frequent inspections and cleanings may be required due to excessive lint from carpeting, bedding mate- rial, etc. It is imperative that the control compart- ment, burners and circulating air passage ways of the appliance be kept clean. S'assurer que le brùleur et le compartiment des commandes sont propres. Voir les instructions d'installation et d'utilisation qui accompagnent l'appareil.

TYPICAL INSTALLATION

Figure 1

Image 2
Contents OTL Report No -F-47-5 MPLDV-35NM-2Table of Contents Model Orifice size Millivolt And Electronic ModelsAll Models Nat PropModel No Shelf Height inches mm Typical LocationsLocation Top Vent ApplicationVent Termination Clearances Vertical Vent Termination ClearancesAppliance and Vent Clearances Horizontal Vent Termination ClearancesRouting GAS Line Typical Installation SequenceDetailed Installation Steps Horizontal Vent Termination Clearances= Clearance to service regulator vent outlet Feet 91cm Canadian Installation US InstallationMeter/regulator assembly Inches 30cm45 1/4 67 1/4 47 1/2 19 3/8 33 5/8 Model No1030 1162 419 1092 Corner Framing with Square Termination SV4.5HT-2Model No Vertical Termination Systems Roof Install the Vent SystemThese fireplaces must be vented directly to the outside Vent Section Length Chart Connection 10 1/2 Min 267 mmVent / 45 Degree Starter Elbow Connection If the vent system extends more than 5 Framing Dimensions for Roof Pitch12/12 Swivel JointBracket Vertical Vent FIGURES/TABLESSupport Ceiling Firestop/Spacer SV4.5VF Detail ViewHorizontal Outside Wall Termination System Plan the vent runFrame exterior wall opening Typical Horizontal Vent InstallationInstall firestop/spacer at ceiling Four incline channels on the collar refer to onMm as shown in Figure Install Firestop/Spacer at exterior wallInstall the desired termination Slide the collars of the termination ontoHorizontal Vent FIGURES/TABLES Exterior Wall ThicknessWall Connection not Directly AT ApplianceConnection Directly AT Appliance Wall Firestop/SpacerWall Ceiling Firestop/Spacer SV4.5VFPull and extend the outer flexible vent pipe Install the Outer Flex PipePull and extend the inner flexible vent pipe Route Flex VentElectronic Wiring See Figure Field WiringMillivolt Wiring See Figure After the wiring is complete, replace the cover plateConnecting GAS Line ING Embers and Volcanic Stones Installing the Glass Door and Optional HoodInstalling the Glass Door Finishing Requirements Burner AdjustmentsBurner Adjustment Wall DetailsMantel Clearances Installation AccessoriesCold Climate Insulation Cat Cat. No. Model No. DescriptionMillivolt Appliances .2 Installation CodeGAS Conversion Kits Pilot Orifice Electronic Appliances Dexen Electronic Valves Model No Orifice size NaturalPage Page 850,043M REV. E 06/2008 West Taft Avenue Orange, CA