Provide adequate clearances around air open- ings and adequate accessibility clearance for service and proper operation. Never obstruct the front openings of the appliance.

These appliances are designed to operate on natural or propane gas only.

Millivolt And Electronic Models -

Millivolt and Electronic models come standard with the manually-modulated gas valve; flame appearance and heat output can be controlled at the gas valve.

Input of millivolt and electronic models is shown in the following table:

Millivolt And Electronic Models with

Manually-Modulated Gas Valve

Natural Gas

Propane Gas

 

Input

 

Input

Model No.

rate

Model No.

rate

 

(BTU/H)

 

(BTU/H)

 

13,000

 

11,500

MPLDV30

to

MPLDV30

to

 

10,000

 

9,000

 

19,000

 

18,000

MPLDV35

to

MPLDV35

to

 

15,000

 

14,000

 

25,000

 

21,500

MPLDV40

to

MPLDV40

to

 

18,500

 

16,500

 

26,000

 

25,000

MPLDV45

to

MPLDV45

to

 

20,000

 

19,000

All Models -

Maximum manifold pressure is 3.5 in. w.c. (0.87 kPa) for natural gas and 10 in. w.c. (2.49 kPa) for LP/Propane gas.

Efficiencies%

 

 

Natural Gas

 

Propane

 

Models

 

 

 

 

 

 

 

 

P4

 

Steady

AFUE

P4

Steady

 

AFUE

 

 

 

 

 

 

State

 

 

State

 

 

MPLDV30

58

 

65

63

58

66

 

64

 

 

 

 

 

 

 

 

 

MPLDV35

60

 

65

63

62

65

 

63

 

 

 

 

 

 

 

 

 

MPLDV40

58

 

67

64

57

67

 

65

 

 

 

 

 

 

 

 

 

MPLDV45

58

 

67

65

60

66

 

64

 

 

 

 

 

 

 

 

 

Note: Power venting of direct vent fireplaces may result in the reduction of efficiencies by as much as ten percent. Consider this in making any venting and heating decisions in any installation application.

Installations at Altitudes of 0 to 4500 ft.- Units are tested and approved for elevations of 0 to 4500 feet (0 to 1372 meters).

Installations at Altitudes above 4500 ft.- For elevations above 4500 feet (1372 meters), install the unit according to the regulations of the local authorities having jurisdiction and, in the USA, the latest edition of the National Fuel Gas Code (ANSI Z223.1) or, in Canada, the latest edition of the CAN1-B149.1 and .2 codes.

Table 1 shows the units' gas orifice size for the elevations indicated.

The millivolt appliances are manually controlled and feature a spark ignitor (piezo) that allows the appliance's pilot gas to be lit without the use of matches or batteries. This system provides continued service in the event of a power outage.

Model

Orifice size

Elevation

Feet

No.

 

 

Nat.

Prop.

(meters)

 

MPLDV30

0.070"

#61

 

(0.039")

 

 

 

 

 

 

 

 

MPLDV35

#45

0.048"

 

(0.082")

0-4500

MPLDV40

#41

#54

(0-1372)

(0.096")

(0.055")

 

MPLDV45

#40

#53

 

(0.098")

(0.0595")

 

Table 1

Do not use these appliances if any part has been under water. Immediately call a qualified, pro- fessional service technician to inspect the ap- pliance and to replace any parts of the control system and any gas control which have been under water.

Ne pas se servir de cet appareil s'il a été plongé dans l'eau, complètement ou en partie. Appeler un technicien qualifié pour inspecter l'appareil et remplacer toute partie du système de contrôle et toute commande qui ont été plongés dans l'eau.

This appliance may be installed in an af- termarket permanently located, manufac- tured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This ap- pliance is not convertible for use with other gases, unless a certified kit is used.

Cet appareil peut être installé dans un maison préfabriquée (É.-U. seulement) ou mobile déjà installée à demeure si les réglements locaux le permettent.

Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique. Ne pas l'utiliser avec d'autres gaz sauf si un kit de con- version certifié est installé.

Test gage connections are provided on the front of the millivolt and electronic gas control valve (identified IN for the inlet and OUT for the manifold side). A 1/8" NPT test gage connec- tion is provided at the inlet and outlet side of the electronic gas control valve.

Minimum inlet gas pressure to these appli- ances is 5.0 inches water column (1.24 kPa) for natural gas and 11 inches water column (2.74 kPa) for propane for the purpose of input adjustment.

Maximum inlet gas supply pressure to these appliances is 10.5 inches water column (2.61 kPa) for natural gas and 13.0 inches water column (3.23 kPa) for propane.

These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve) during any pressure testing of the gas supply piping sys- tem at test pressures equal to or less than 1/2 psig (3.5 kPa).

These appliances and their individual shut-off valves must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of 1/2 psig (3.5 kPa).

These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance.

These heater rated appliances are intended for use as supplemental heaters only. Using these appliances as a primary heat source may void the manufacturers warranty.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Turn off the gas supply to the appliance and have it serviced by a qualified professional, as it may not be op- erating correctly.

3

Image 3
Contents MPLDV-35NM-2 OTL Report No -F-47-5Table of Contents Nat Prop Millivolt And Electronic ModelsAll Models Model Orifice sizeTop Vent Application Typical LocationsLocation Model No Shelf Height inches mmHorizontal Vent Termination Clearances Vertical Vent Termination ClearancesAppliance and Vent Clearances Vent Termination ClearancesHorizontal Vent Termination Clearances Typical Installation SequenceDetailed Installation Steps Routing GAS LineInches 30cm Canadian Installation US InstallationMeter/regulator assembly = Clearance to service regulator vent outlet Feet 91cmCorner Framing with Square Termination SV4.5HT-2 Model No1030 1162 419 1092 45 1/4 67 1/4 47 1/2 19 3/8 33 5/8Model No Install the Vent System These fireplaces must be vented directly to the outsideVertical Termination Systems Roof Vent Section Length Chart 10 1/2 Min 267 mm Vent / 45 Degree Starter Elbow ConnectionConnection Swivel Joint Framing Dimensions for Roof Pitch12/12 If the vent system extends more than 5Ceiling Firestop/Spacer SV4.5VF Detail View Vertical Vent FIGURES/TABLESSupport BracketPlan the vent run Horizontal Outside Wall Termination SystemFour incline channels on the collar refer to on Typical Horizontal Vent InstallationInstall firestop/spacer at ceiling Frame exterior wall openingSlide the collars of the termination onto Install Firestop/Spacer at exterior wallInstall the desired termination Mm as shown in FigureExterior Wall Thickness Horizontal Vent FIGURES/TABLESWall Firestop/Spacer Connection not Directly AT ApplianceConnection Directly AT Appliance WallCeiling Firestop/Spacer SV4.5VF WallRoute Flex Vent Install the Outer Flex PipePull and extend the inner flexible vent pipe Pull and extend the outer flexible vent pipeAfter the wiring is complete, replace the cover plate Field WiringMillivolt Wiring See Figure Electronic Wiring See FigureConnecting GAS Line Installing the Glass Door and Optional Hood Installing the Glass DoorING Embers and Volcanic Stones Wall Details Burner AdjustmentsBurner Adjustment Finishing RequirementsInstallation Accessories Cold Climate InsulationMantel Clearances Cat. No. Model No. Description Cat.2 Installation Code GAS Conversion KitsMillivolt Appliances Model No Orifice size Natural Pilot Orifice Electronic Appliances Dexen Electronic ValvesPage Page West Taft Avenue Orange, CA 850,043M REV. E 06/2008