LG Electronics MP03-VDLPM installation instructions Model No

Page 9

FIREPLACE SPECIFICATIONS

F

G

6 5/8

(168)

TOP VIEW

4 3/4

(121)

LEFT SIDE VIEW

E

13 11/64

(335)

A

C

D

2 9/32

(58)

FRONT VIEW

17

(432)

3 5/16 (100 mm)

10

(254 mm)

B

H

RIGHT SIDE VIEW

1

(25.4)

Unit Dimensions

Model No.

 

A

B

C

D

E

F

G

H

 

 

 

 

 

 

 

 

 

 

MPLDV30

in.

40 1/2

37 1/2

20 5/8

24 1/8

30 1/4

19 3/4

9 7/8

27 1/4

 

 

 

 

 

 

 

 

 

mm

1029

953

534

613

768

502

251

692

 

 

 

 

 

 

 

 

 

 

 

MPLDV35

in.

40 1/2

37 1/2

20 5/8

29 1/8

35 1/4

24 3/4

12 3/8

27 1/4

 

 

 

 

 

 

 

 

 

mm

1029

953

534

740

895

629

314

692

 

 

 

 

 

 

 

 

 

 

 

MPLDV40

in.

45 1/2

42 1/2

25 5/8

34 1/8

40 1/4

29 3/4

14 7/8

32 1/4

 

 

 

 

 

 

 

 

 

mm

1156

1080

651

867

1022

756

378

819

 

 

 

 

 

 

 

 

 

 

 

MPLDV45

in.

45 1/2

42 1/2

25 5/8

39 1/8

45 1/4

34 3/4

17 3/8

32 1/4

 

 

 

 

 

 

 

 

 

mm

1156

1080

651

994

1149

883

441

819

 

 

 

 

 

 

 

 

 

 

 

Figure 11

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

9

Image 9
Contents MPLDV-35NM-2 OTL Report No -F-47-5Table of Contents All Models Millivolt And Electronic ModelsModel Orifice size Nat PropLocation Typical LocationsModel No Shelf Height inches mm Top Vent ApplicationAppliance and Vent Clearances Vertical Vent Termination ClearancesVent Termination Clearances Horizontal Vent Termination ClearancesDetailed Installation Steps Typical Installation SequenceRouting GAS Line Horizontal Vent Termination ClearancesMeter/regulator assembly Canadian Installation US Installation= Clearance to service regulator vent outlet Feet 91cm Inches 30cm1030 1162 419 1092 Model No45 1/4 67 1/4 47 1/2 19 3/8 33 5/8 Corner Framing with Square Termination SV4.5HT-2Model No Install the Vent System These fireplaces must be vented directly to the outsideVertical Termination Systems Roof Vent Section Length Chart 10 1/2 Min 267 mm Vent / 45 Degree Starter Elbow ConnectionConnection 12/12 Framing Dimensions for Roof PitchIf the vent system extends more than 5 Swivel JointSupport Vertical Vent FIGURES/TABLESBracket Ceiling Firestop/Spacer SV4.5VF Detail ViewPlan the vent run Horizontal Outside Wall Termination SystemInstall firestop/spacer at ceiling Typical Horizontal Vent InstallationFrame exterior wall opening Four incline channels on the collar refer to onInstall the desired termination Install Firestop/Spacer at exterior wallMm as shown in Figure Slide the collars of the termination ontoExterior Wall Thickness Horizontal Vent FIGURES/TABLESConnection Directly AT Appliance Connection not Directly AT ApplianceWall Wall Firestop/SpacerCeiling Firestop/Spacer SV4.5VF WallPull and extend the inner flexible vent pipe Install the Outer Flex PipePull and extend the outer flexible vent pipe Route Flex VentMillivolt Wiring See Figure Field WiringElectronic Wiring See Figure After the wiring is complete, replace the cover plateConnecting GAS Line Installing the Glass Door and Optional Hood Installing the Glass DoorING Embers and Volcanic Stones Burner Adjustment Burner AdjustmentsFinishing Requirements Wall DetailsInstallation Accessories Cold Climate InsulationMantel Clearances Cat. No. Model No. Description Cat.2 Installation Code GAS Conversion KitsMillivolt Appliances Model No Orifice size Natural Pilot Orifice Electronic Appliances Dexen Electronic ValvesPage Page West Taft Avenue Orange, CA 850,043M REV. E 06/2008