STANDARD VENT ARRANGEMENT

3.6 in.

 

 

17 in. (432mm) MIN.,*

 

 

(91mm)

 

2.6 in.

80 in. (2.03m) MAX.

WALL

 

 

 

(67mm)

 

 

 

 

 

 

 

 

 

 

2.1 in. (54.5mm)

FIGURE 17

*If the horizontal distance is less than 30 in. (760mm), the restricter plate must be installed (see Figure 22).

VENT ASSEMBLY

The vent tube and terminal can be assembled as shown in Figure 18. There are springs fastened inside the corrugated tube. When the vent tubes are pulled to a required length, the springs will still be equally spaced.

SPRINGCLAMP

FIGURE 18

SECURING VENT TERMINATION ASSEMBLY TO THE EXTERIOR WALL.

Some models are supplied with trim plates which may be used to cover the holes in the wall (see Figures 1 and 19). Slide one trim plate (if supplied) over the outer corrugated tube, then insert the outer corrugated tube through the clearance hole from exterior wall. Secure the trim plate to the exterior wall, then secure the vent terminal to the exterior wall with 4 screw anchors (included) appropriate for the type of wall construction. Caulk the junction of the vent terminal base plate and the exterior wall with exterior type sealant (not included). Slide the trim plate (inside) over the outer corrugated tube and fasten the trim plate to the interior wall. Caulk the junction of the outer corrugated tube and the trim plate (inside) with suitable sealant.

TRIM PLATE

 

(INSIDE)

SEALANT

TRIM PLATE (OUTSIDE)

FIGURE 19

UNCOMPRESSING THE CORRUGATED TUBING

1.Pull the inner corrugated tube towards the water heater and leave some length over the water heater’s center for bending.

2.Pull the outer corrugated tube toward the water heater and leave it 1 in. (25mm) shorter than the inner corrugated tube.

3.Make sure there are two springs evenly spaced at the bend in the tube.

4.Use metal hangers to keep venting level or with a slope upward from the heater to terminal.

SPRING

REDUCER

H

FIGURE 20

Bend both the corrugated tubes toward the water heater’s flue connection.

FIGURE 21

VENT RESTRICTER PLATE

For short horizontal vent runs (see Figure 17) place the restricter plate over the flue tube reducer before connecting the inner cor- rugated tube to the flue tube reducer. DO NOT use the restricter plate if the horizontal run is greater than 30 in. (760mm).

UPPER AIR

RESTRICTER

INLET BOX

PLATE

FLUE TUBE

REDUCER

FIGURE 22

Pull and connect the inner corrugated tube to the water heater’s flue tube reducer with hi-temp red silicone (included) and gear clamp. Make sure this connection is tight and leak proof.

*The sealant between the inner corrugated tube and water heater’s flue tube reducer must be hi-temp red silicone or other material suitable for 600°F (315°C) continuous service.

17

Image 17
Contents Residential GAS Water Heaters Important Definitions Safe INSTALLATION, USE and ServiceGeneral Safety Introduction Table of ContentsKeep Clear of ALL Obstructions GET to Know Your Water Heater Replacement Parts Typical InstallationHotter Water can Scald Mixing Valve UsageFacts to Consider about the Location Locating the NEW Water HeaterVent Termination Insulation BlanketsVentilation for Appliances Located in Confined Spaces Required Ability Installing the NEW Water HeaterInspect Shipment GeneralValve and Pipe Insulation if Supplied TEMPERATURE-PRESSURE Relief ValveGAS Piping Water Potable Heating and Space HeatingClosed Water System GAS Piping with Flexible Connector Venting High Altitude InstallationsSediment Traps Filling the Water Heater Vent Terminal Clearances Combustion AIR and VentilationVent Connections DV Termination Safety CoverLocating Clearance Hole for Vent High Rise Vent ArrangementSecuring Vent Termination Assembly to the Exterior Wall Vent AssemblyStandard Vent Arrangement Uncompressing the Corrugated TubingOffset Vent Arrangement Figure D TOP KnobTemperature Regulation Temperature RegulationExternal Damage For Your InformationStart UP Conditions Operational ConditionsAIR in HOT Water Faucets Pilot and Main Burner MaintenanceVenting System Inspection Anode ROD Maintenance Temperature & Pressure Relief ValveDraining Cathodic Protection AnodeDrain Valve Washer Replacement Leakage Checkpoints ServiceProblem Possible Causes Correction Troubleshooting GuidelinesERY Slow HOT Water RecovDrip from Relief Valve Thermostat Fails toPage Conditions and Exceptions Series Tank PartsClaim Procedure Service and Labor ResponsibilityInstallation Information Limitation on Implied WarrantiesTennessee Waltz Parkway Ashland CITY, TN

186589-001 specifications

State Industries 186589-001 is a highly efficient water heater designed to meet both residential and commercial hot water demands. Known for its durability and exceptional performance, this unit is a popular choice among homeowners and business owners alike.

One of the standout features of the State Industries 186589-001 is its robust construction. The tank is made from high-quality materials that offer superior insulation, reducing heat loss and improving overall energy efficiency. This ensures a longer lifespan for the unit while minimizing operating costs. The model also features a glass-lined tank, which prevents corrosion and extends the longevity of the water heater.

The 186589-001 employs innovative heating technologies, including an advanced control system that provides precise temperature regulation. This allows users to set their desired water temperature easily, ensuring optimal comfort and safety. With a powerful heating element, the water heater can quickly heat water to desired levels, providing a reliable supply for various applications, from daily bathing to commercial needs.

Furthermore, the State Industries water heater is equipped with multiple safety features. An automatic shut-off function is integrated to protect against overheating, ensuring user safety during operation. Additionally, the model comes with a pressure relief valve, preventing potential hazards from excessive pressure build-up.

In terms of energy efficiency, the 186589-001 meets and often exceeds current industry standards. Its design minimizes energy consumption, which not only lowers utility bills for users but also aligns with environmentally sustainable practices.

The unit is designed for easy installation, making it convenient for both professionals and DIY enthusiasts. Clear instructions are provided, and the compact size allows it to fit in tight spaces, an advantage for those with limited installation options.

Overall, the State Industries 186589-001 stands as a reliable choice for those seeking a quality water heater with excellent features, advanced technology, and safety characteristics. Its commitment to durability and efficiency makes it a valuable investment for anyone in need of consistent hot water supply.