State Industries 186589-001 instruction manual Table of Contents, Introduction

Page 4

TABLE OF CONTENTS

SAFE INSTALLATION, USE AND SERVICE . . . . . . . . . . . . . 2 GENERAL SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 TABLE OF CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Preparing for the installation . . . . . . . . . . . . . . . . . . . . . . . 4

INSTALLATION REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS . . . . . . . . . . . . . 5 TYPICAL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Get to know your water heater . . . . . . . . . . . . . . . . . . . . . 6 Replacement parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Mixing valve useage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 LOCATING THE NEW WATER HEATER . . . . . . . . . . . . . . . . 8 Facts to consider about location . . . . . . . . . . . . . . . . . . . . 8 Insulation blankets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Ventilation for appliances located in confined spaces . . . . 9 Vent termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 INSTALLING THE NEW WATER HEATER . . . . . . . . . . . . 10-18 Required ability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Inspect shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Water piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 T & P valve and pipe insulation (if supplied) . . . . . . . . . . .11 Temperature-pressure relief valve . . . . . . . . . . . . . . . . . . .11 Water (potable) heating and space heating. . . . . . . . . . . 12 Closed water system . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Gas piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Sediment traps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Filling the water heater . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Venting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 High altitude installations . . . . . . . . . . . . . . . . . . . . . . . . . 14 Combustion air and ventilation . . . . . . . . . . . . . . . . . . . . 15 Vent terminal clearances . . . . . . . . . . . . . . . . . . . . . . . . . 15 Vent connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Locating clearance hole for vent . . . . . . . . . . . . . . . . . . . 16

High rise vent arrangement . . . . . . . . . . . . . . . . . . . . . . . 16 Standard vent arrangement . . . . . . . . . . . . . . . . . . . . . . . 17 Securing vent termination assembly to the exterior wall . 17 Uncompressing the corrugated tubing. . . . . . . . . . . . . . . 17 Vent restricter plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Offset vent arrangement Condition 1. . . . . . . . . . . . . . . . 18 Offset vent arrangement Condition 2. . . . . . . . . . . . . . . . 18

LIGHTING & OPERATING LABEL . . . . . . . . . . . . . . . . . . . . 19 TEMPERATURE REGULATION . . . . . . . . . . . . . . . . . . . . . . 20 Temperature regulation . . . . . . . . . . . . . . . . . . . . . . . . . . 20 FOR YOUR INFORMATION . . . . . . . . . . . . . . . . . . . . . . . 21-22 External damage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Start up conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Condensate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Smoke/odor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Thermal expansion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Strange sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Operational Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Smelly water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 “Air” in hot water systems . . . . . . . . . . . . . . . . . . . . . . . . 22 High water temperature shut off system . . . . . . . . . . . . . 22 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23-25 Venting system inspection . . . . . . . . . . . . . . . . . . . . . . . . 23 Pilot and main burner. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Temperature & pressure relief valve . . . . . . . . . . . . . . . . 24 Draining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Cathodic protection - anode. . . . . . . . . . . . . . . . . . . . . . . 24 Anode rod maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . 24 Drain valve washer replacement . . . . . . . . . . . . . . . . . . . 25 LEAKAGE CHECKPOINTS. . . . . . . . . . . . . . . . . . . . . . . . . . 26 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 TROUBLESHOOTING GUIDELINES . . . . . . . . . . . . . . . . 27-28 NOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30-31

INTRODUCTION

Thank You for purchasing this water heater. Properly installed and maintained, it should give you years of trouble free service.

Abbreviations Found In This Instruction Manual:

CSA

- Canadian Standards Association

ANSI

- American National Standards Institute

NFPA

- National Fire Protection Association

ASME

- American Society of Mechanical Engineers

GAMA

- Gas Appliance Manufacturer’s Association

UL

- Underwriters Laboratories Inc.

This gas-fired water heater is design certified by Underwriters Laboratories Inc. under American National Standard/CSA Stan- dard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current edition).

PREPARING FOR THE INSTALLATION

1.Read the “General Safety” section, page 3 of this manual first and then the entire manual carefully. If you don’t follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE. This manual contains instructions for the installation, operation, and maintenance of the gas-fired water heater. It also contains warnings throughout the man- ual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL BEFORE

ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.

2.The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the National Fuel Gas Code ANSI Z223.1/NFPA. This publication is available from the Canadian Standards Association, 8501 East Pleas- ant Valley Road, Cleveland, OH 44131.

3.If after reading this manual you have any questions or do not understand any portion of the instructions, call the local gas utility or the manufacturer whose name appears on the rating plate.

4.Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe instal- lation are very important in preventing death from possible carbon monoxide poisoning and fires, see Figures 1 and 2. Examine the location to ensure the water heater complies with the “Locating the New Water Heater” section in this manual.

5.For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation proce- dures. Instructions may be obtained from California Office of the State Architect, 400 P Street, Sacramento, CA 95814.

6.Massachusetts Code requires this water heater to be in- stalled in accordance with Massachusetts 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00. For more informa- tion see next page.

4

Image 4
Contents Residential GAS Water Heaters Safe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Table of Contents IntroductionKeep Clear of ALL Obstructions Typical Installation GET to Know Your Water Heater Replacement PartsMixing Valve Usage Hotter Water can ScaldLocating the NEW Water Heater Facts to Consider about the LocationVentilation for Appliances Located in Confined Spaces Insulation BlanketsVent Termination Installing the NEW Water Heater Required AbilityInspect Shipment GeneralTEMPERATURE-PRESSURE Relief Valve Valve and Pipe Insulation if SuppliedClosed Water System Water Potable Heating and Space HeatingGAS Piping GAS Piping with Flexible Connector Sediment Traps Filling the Water Heater High Altitude InstallationsVenting Combustion AIR and Ventilation Vent Terminal ClearancesDV Termination Safety Cover Vent ConnectionsLocating Clearance Hole for Vent High Rise Vent ArrangementVent Assembly Securing Vent Termination Assembly to the Exterior WallStandard Vent Arrangement Uncompressing the Corrugated TubingOffset Vent Arrangement TOP Knob Figure DTemperature Regulation Temperature RegulationFor Your Information External DamageStart UP Conditions Operational ConditionsAIR in HOT Water Faucets Venting System Inspection MaintenancePilot and Main Burner Temperature & Pressure Relief Valve Anode ROD MaintenanceDraining Cathodic Protection AnodeDrain Valve Washer Replacement Service Leakage CheckpointsTroubleshooting Guidelines Problem Possible Causes CorrectionSlow HOT Water Recov ERYDrip from Relief Valve Thermostat Fails toPage Series Tank Parts Conditions and ExceptionsService and Labor Responsibility Claim ProcedureInstallation Information Limitation on Implied WarrantiesTennessee Waltz Parkway Ashland CITY, TN

186589-001 specifications

State Industries 186589-001 is a highly efficient water heater designed to meet both residential and commercial hot water demands. Known for its durability and exceptional performance, this unit is a popular choice among homeowners and business owners alike.

One of the standout features of the State Industries 186589-001 is its robust construction. The tank is made from high-quality materials that offer superior insulation, reducing heat loss and improving overall energy efficiency. This ensures a longer lifespan for the unit while minimizing operating costs. The model also features a glass-lined tank, which prevents corrosion and extends the longevity of the water heater.

The 186589-001 employs innovative heating technologies, including an advanced control system that provides precise temperature regulation. This allows users to set their desired water temperature easily, ensuring optimal comfort and safety. With a powerful heating element, the water heater can quickly heat water to desired levels, providing a reliable supply for various applications, from daily bathing to commercial needs.

Furthermore, the State Industries water heater is equipped with multiple safety features. An automatic shut-off function is integrated to protect against overheating, ensuring user safety during operation. Additionally, the model comes with a pressure relief valve, preventing potential hazards from excessive pressure build-up.

In terms of energy efficiency, the 186589-001 meets and often exceeds current industry standards. Its design minimizes energy consumption, which not only lowers utility bills for users but also aligns with environmentally sustainable practices.

The unit is designed for easy installation, making it convenient for both professionals and DIY enthusiasts. Clear instructions are provided, and the compact size allows it to fit in tight spaces, an advantage for those with limited installation options.

Overall, the State Industries 186589-001 stands as a reliable choice for those seeking a quality water heater with excellent features, advanced technology, and safety characteristics. Its commitment to durability and efficiency makes it a valuable investment for anyone in need of consistent hot water supply.