State Industries 186589-001 Temperature & Pressure Relief Valve, Draining, Anode ROD Maintenance

Page 24

TEMPERATURE & PRESSURE RELIEF VALVE

At least once a year, the temperature and pressure relief valve, Figure 1, must be checked to ensure that it is in operating condi- tion. Lift the lever at the top of the valve several times until the valve seats properly and operates freely.

If water does not flow, remove the valve and inspect for obstruc- tions or corrosion. Have a qualified servicer replace with a new valve of the recommended size as necessary. Do not attempt to repair the valve, as this could result in improper operation and a tank explosion. In areas with poor water conditions, it may be necessary to inspect the T&P valve more frequently.

THE WATER PASSING OUT OF THE VALVE DURING THIS CHECKING OPERATION MAY BE EXTREMELY HOT. AVOID CONTACT AND DISCHARGE SAFELY TO PREVENT WATER DAMAGE.

DRAINING

If the heater is to be shut off and exposed to freezing tempera- tures, it must be drained. Water, if left in the tank and allowed to freeze, will damage the heater.

Turn off the gas and cold water inlet valve to the heater, Figure 1.

Open a nearby hot water faucet and the heater drain valve.

BE CAREFUL TO GRASP THE DRAIN VALVE HANDLE SO THAT THE HAND IS NOT EXPOSED TO HOT WATER. IF DESIRED, A HOSE MAY BE CONNECTED TO THE DRAIN VALVE TO CARRY THE WATER AWAY.

The water CAN BE HOT.

The drain valve must be left open during the shutdown pe- riod.

To restart heater, refer to the FILLING instructions under OP-

ERATION.

Periodically open the drain valve and allow the water to run until it flows clean. This will help prevent sediment build-up in the tank.

It is normal for lime and scale deposits to form within the tank. Such deposits will not be removed by periodic draining. It is necessary to chemically delime the affected parts in water areas where such deposits are encountered. Contact your dealer or plumber for deliming information.

CATHODIC PROTECTION - ANODE

The anode rod within the tank is designed to be slowly con- sumed cathodically, minimizing corrosion in the glass-lined tank. A hydrogen sulfide (rotten egg) odor may result if water contains high sulfate and/or minerals. Chlorinating the water supply should minimize the problem. (See EXTENDED NON-

USE PERIODS).

NOTE: Anode must remain installed (except for inspection) to avoid shortening tank life. See LIMITED WARRANTY. Replace as necessary.

ANODE ROD MAINTENANCE

The anode rod is used to protect the tank from corrosion. Most hot water tanks are equipped with an anode rod. The submerged rod sacrifices itself to protect the tank. Instead of corroding the tank, water ions attack and eat away the anode rod. This does not affect the water’s taste or color. The rod must be maintained to keep the tank in operating condition.

Anode deterioration depends on water conductivity, not neces- sarily water condition. A corroded or pitted anode rod indicates high water conductivity and should be checked and/or replaced more often than an anode rod that appears to be intact. Re- placement of a depleted anode rod can extend the life of your water heater. Inspection should be conducted by a qualified technician, and at a minimum should be checked annually after the warranty period.

24

Image 24
Contents Residential GAS Water Heaters Safe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Table of Contents IntroductionKeep Clear of ALL Obstructions Typical Installation GET to Know Your Water Heater Replacement PartsMixing Valve Usage Hotter Water can ScaldLocating the NEW Water Heater Facts to Consider about the LocationInsulation Blankets Ventilation for Appliances Located in Confined SpacesVent Termination Installing the NEW Water Heater Required AbilityInspect Shipment GeneralTEMPERATURE-PRESSURE Relief Valve Valve and Pipe Insulation if SuppliedWater Potable Heating and Space Heating Closed Water SystemGAS Piping GAS Piping with Flexible Connector High Altitude Installations Sediment Traps Filling the Water HeaterVenting Combustion AIR and Ventilation Vent Terminal ClearancesDV Termination Safety Cover Vent ConnectionsLocating Clearance Hole for Vent High Rise Vent ArrangementVent Assembly Securing Vent Termination Assembly to the Exterior WallStandard Vent Arrangement Uncompressing the Corrugated TubingOffset Vent Arrangement TOP Knob Figure DTemperature Regulation Temperature RegulationFor Your Information External DamageStart UP Conditions Operational ConditionsAIR in HOT Water Faucets Maintenance Venting System InspectionPilot and Main Burner Temperature & Pressure Relief Valve Anode ROD MaintenanceDraining Cathodic Protection AnodeDrain Valve Washer Replacement Service Leakage CheckpointsTroubleshooting Guidelines Problem Possible Causes CorrectionSlow HOT Water Recov ERYDrip from Relief Valve Thermostat Fails toPage Series Tank Parts Conditions and ExceptionsService and Labor Responsibility Claim ProcedureInstallation Information Limitation on Implied WarrantiesTennessee Waltz Parkway Ashland CITY, TN

186589-001 specifications

State Industries 186589-001 is a highly efficient water heater designed to meet both residential and commercial hot water demands. Known for its durability and exceptional performance, this unit is a popular choice among homeowners and business owners alike.

One of the standout features of the State Industries 186589-001 is its robust construction. The tank is made from high-quality materials that offer superior insulation, reducing heat loss and improving overall energy efficiency. This ensures a longer lifespan for the unit while minimizing operating costs. The model also features a glass-lined tank, which prevents corrosion and extends the longevity of the water heater.

The 186589-001 employs innovative heating technologies, including an advanced control system that provides precise temperature regulation. This allows users to set their desired water temperature easily, ensuring optimal comfort and safety. With a powerful heating element, the water heater can quickly heat water to desired levels, providing a reliable supply for various applications, from daily bathing to commercial needs.

Furthermore, the State Industries water heater is equipped with multiple safety features. An automatic shut-off function is integrated to protect against overheating, ensuring user safety during operation. Additionally, the model comes with a pressure relief valve, preventing potential hazards from excessive pressure build-up.

In terms of energy efficiency, the 186589-001 meets and often exceeds current industry standards. Its design minimizes energy consumption, which not only lowers utility bills for users but also aligns with environmentally sustainable practices.

The unit is designed for easy installation, making it convenient for both professionals and DIY enthusiasts. Clear instructions are provided, and the compact size allows it to fit in tight spaces, an advantage for those with limited installation options.

Overall, the State Industries 186589-001 stands as a reliable choice for those seeking a quality water heater with excellent features, advanced technology, and safety characteristics. Its commitment to durability and efficiency makes it a valuable investment for anyone in need of consistent hot water supply.