State Industries GS675YRVLT Typical Installation, Replacement Parts and Deliming Products

Page 7

TYPICAL INSTALLATION

REPLACEMENT PARTS AND DELIMING PRODUCTS

Replacement parts and recommended delimer may be ordered through authorized servicers or distributors. Refer to the Yellow Pages for where to call or contact the water heater manufacturer at, 500 Tennessee Waltz Parkway, Ashland City, TN 37015. When ordering parts, provide complete model and serial numbers (see rating plate), quantity and name of part desired, see Figure 1. Standard hardware items may be purchased locally.

VACUUM RELIEF VALVE

*INSTALL PER LOCAL

CODES

(A)

VENT PIPE

(O)

INLET DIP TUBE

(B)

ANODE

(P)

TEMPERATURE AND

(C)

HOT WATER OUTLET

 

PRESSURE RELIEF VALVE

(D)

OUTLET (120 VAC)

(Q)

RATING PLATE

(E)

FLUE BAFFLE

(R)

INSULATION

(F)

GAS SUPPLY

(S)

VENT TERMINAL

(G)

MAIN MANUAL GAS

(T)

DRAIN VALVE

 

SHUT OFF VALVE

(U)

IGNITER AND MAIN

(H)

GROUND JOINT UNION

 

BURNER

(J)

DIRT LEG

(V)

FLUE

(K)

OUTER DOOR

(W)

METAL DRAIN PAN

(L)

UNION

(X)

CONTROL

(M)

INLET WATER SHUT

(Y)

CONTROL HARNESS*

 

OFF VALVE

(Z)

MOTOR & BLOWER

(N)

COLD WATER INLET

(AA) CONDENSATE FITTING

INSTALL THERMAL EXPANSION

TANK IF WATER HEATER IS INSTALLED IN A CLOSED WATER SYSTEM.

FIGURE 1.

TEMPERATURE INDICATORS

TEMPERATURE ADJUSTMENT BUTTONS

(U)NATURAL GAS MAIN BURNER WITH IGNITER ASSEMBLY

(U)PROPANE GAS MAIN BURNER WITH IGNITER ASSEMBLY

(SIDE VIEW)

7

Image 7
Contents 197218-002 Whenever maintenance adjustment or service is requiredImportant Definitions Safe INSTALLATION, USE and ServiceGeneral Safety General Safety Introduction Table of ContentsBELOW. Keep Clear of ALL Obstructions Replacement Parts and Deliming Products Typical InstallationMixing Valve Usage Facts to Consider About the Location Locating the NEW Water HeaterInsulation Blankets ALL AIR from Outdoors See Figures 7, 8 ALL AIR from Inside Buildings SeeChemical Vapor Corrosion Installing the NEW Water HeaterWater Piping Valve and Pipe Insulation if supplied Temperature-Pressure Relief ValveGas Piping GAS Piping with Flexible ConnectorFilling the Water Heater Sediment TrapsVenting Vent Pipe Termination Planning the Vent System Horizontal Vent ClearancesVent Hoods MAY be Extremely HOT During Operation Condensate Blower Assembly InstallationVent Terminal INSTALLATION, Sidewall Installation of Vent SystemPower Vent Wiring Schematic Installation of Vertical Vent System Installation of Vent SYSTEM, SidewallRecommended BRUSH* Size for Primer Cement Applications Vent Pipe PreparationStep G Step BStep E Step FDo not TRY to Light the Burner by Hand Power Before ServicingDo not try to light the burner by hand What to do if YOU Smell GASTemperature Setting Temperature RegulationStart UP Conditions For Your InformationOperational Conditions Burner Operation and Inspection Periodic MaintenanceBurner Cleaning Venting System InspectionAnode ROD Inspection Temperature-Pressure Relief Valve OperationDraining Leakage Checkpoints ServicePropane Burner Assembly Natural GAS Burner Repair Parts ListTrouble Shooting Troubleshooting GuidelinesBurner flame, ensure flame is steady see #8 below Troubleshooting Guidelines Page Page Important Information Conditions and ExceptionsTennessee Waltz Parkway Ashland City, TN

GS675YRVLT specifications

The State Industries GS675YRVLT is a highly efficient and reliable water heater designed for residential use. It features advanced technologies and specifications that cater to the needs of modern households, making it an excellent choice for those seeking comfort and convenience in their hot water supply.

One of the standout features of the GS675YRVLT is its Energy Star certification, which signifies that it meets strict energy efficiency guidelines set by the U.S. Environmental Protection Agency. This certification not only ensures lower utility bills for homeowners but also contributes to reduced environmental impact, aligning with sustainable practices.

The unit is equipped with a powerful 67-gallon tank, providing ample hot water for larger families or households with high hot water demands. With its recovery rate, it can deliver consistent hot water, making it ideal for simultaneous use in multiple outlets, such as showers, dishwashers, and laundry machines.

A key characteristic of the GS675YRVLT is its durable construction. The tank is built with a glass lining that resists corrosion, extending the life of the water heater and minimizing the need for frequent replacements. Additionally, the reinforced insulation helps retain heat, improving the overall energy efficiency of the system.

The GS675YRVLT utilizes advanced heating technology. It features a high-efficiency gas burner that accelerates the heating process, ensuring quicker access to hot water. The combination of this burner and the unit's insulation means that users benefit from lower energy consumption without sacrificing performance.

Safety is also a priority in the design of this water heater. The GS675YRVLT includes a pressure relief valve, which prevents excessive pressure buildup, and it is equipped with a flame arrestor, minimizing the risk of combustion. These safety features are essential for ensuring peace of mind for homeowners.

User-friendly controls and a digital thermostat are other notable aspects of this unit. They allow for easy temperature adjustments and monitoring of energy usage.

In summary, the State Industries GS675YRVLT is a top-tier water heater that combines energy efficiency, robust construction, advanced technologies, and safety features. It is an ideal solution for those looking to enhance their home's hot water system while also being considerate of energy consumption and environmental responsibility.