England's Stove Works PELLET STOVES Ash Removal And Disposal, Daily Ash Maintenance

Page 13
ASH REMOVAL AND DISPOSAL
Bottom Auger Tube
Illustration 2

NOTE: The instructions below concerning the cleaning of the burn pot and wear plate area are especially important to the function of your stove. Failure to follow them regularly can result in burn-back and can damage your unit and/or void your warranty.

ASH REMOVAL AND DISPOSAL

IMPORTANT: While the amount of ash generated by this unit is not excessive compared to log-burning woodstoves, keeping the unit clean and free of ash is essential for peak performance. Too much ash build-up hampers airflow and reduces the unit’s efficiency, and can cause smoke-back. Follow these directions at least as frequently as the schedule below, or more often if needed.

Daily Ash Maintenance

Press the “OFF” touch pad and allow the stove to burn for five (5) minutes prior to opening the door. A long-handled screwdriver or long-handled putty knife can be used to scrape off any build-up or crust in the burn pot area. This can then be pushed to the left or right into the ash storage area.

Semi-Weekly Ash Removal

Twice each week: Shut the unit down by pressing the “OFF” pad and allowing the unit to go through the complete Shut-Down cycle. Allow the unit to completely cool down and then remove the ashes with a scoop. The ashes should be placed in a non- combustible container with an airtight lid and should always be placed on a non-combustible surface or on the ground until completely cooled and free of hot cinders.

Once the ash is removed, the burn pot should be given a thorough inspection. Remove and clean the burn pot wear plate (refer to the exploded diagram in the rear of this manual – Illustration 6, and the close- up diagram shown here), and remove any ash build- up in the area below the wear plate. Also, be sure there are no ashes or obstructions in the tube under

the wear plate. Check for any build-up in the front of the burn area. Clean out all air holes (if necessary a 1/8” drill bit can be used) --these air holes should be kept clean, as they supply combustion air under and around the pellet fuel. The burn pot assembly should also be thoroughly cleaned, including the feed auger and feed tube. When replacing the wear plate, ensure that it lies flat in the firebox and no gaps (from ash residue) are under it.

IMPORTANT: Ash build-up under the wear plate can cause the unit to malfunction.

13

Image 13
Contents SAFETY NOTICE INSTALLATION & OPERATION MANUALPlease Note the Following Precautionary Statements Save These InstructionsThank you for purchasing this fine product from England’s Stove Works A letter from our Technical Support departmentWishing you years of efficient, quality and “comfy” heating A NOTE ON COLD AIR RETURNS AND CENTRAL FURNACES BEFORE RE-STARTING YOUR UNITIN THE EVENT OF SMOKE-BACK Please call Technical Support at 800 245-6489 with any questionsIMPORTANT INFORMATION UNIT PREPARATION Proper Impingement Baffle Plate Placement in Pellet Stove Firebox FLUE SYSTEM NOTE See the installation drawing later in this manual IllustrationBe sure to check local codes in your area Pellet Vent PipeImportant Notes Concerning Installation Mobile Home InstallationThrough the Ceiling Existing Flue SystemFLOOR AND WALL PROTECTION Freestanding Pellet InstallationFloor Protection Wall ProtectionOPERATING INSTRUCTIONS START- UP PROCEDUREHorizontal Feed System Automatic Start-UpE-Codes SHUT-DOWN PROCEDUREuntil the room air blower begins to operate Unit’s State Before Power Loss Power OutageState When Power Returns Refueling the UnitASH REMOVAL AND DISPOSAL Daily Ash MaintenanceSemi-Weekly Ash Removal Monthly Ash Removal Annual CleaningCAUTION UNPLUG THE UNIT PRIOR TO ANY SERVICE WORK MAINTENANCERear Panel Removal Auger MotorsConvection Blower Vacuum SwitchCombustion Blower GasketsControl Board Call Technical Support at 800CAUTION Moving Parts May Cause Injury Do NOT Operate with Panels Off Disconnect Power Before Servicing UnitDANGER Parts May Be Hot. Risk of Electric Shock Illustration 4 PU-CB04 Control Board Diagram WiringIllustration Hopper Lid Latch Adjusting your Hopper Lid LatchesThermostats ACCESSORY ITEMSAC-103, AC-103BN Lip Trim AC-106-P SH-106-P, AC-106-PBN Window TrimOPTIONS service@englanderstoves.comTechnical Support Department P.O. BoxDimensions of your pellet unit Pellet Stove - Exploded View Diagram28 ½”W x 30”H x 28 ½”D 375 lbsProblem TROUBLE-SHOOTING GUIDESolution CauseFROM THE DATE OF PURCHASE TO THE ORIGINAL OWNER LIMITED 5 YEAR WARRANTYProcedure The manufacturer extends the following warrantiesDEALER INFORMATION WARRANTY REGISTRATION for England’s Stove WorksUNIT INFORMATION