Desa S26NTA, S26PTA installation manual Cleaning

Page 20

Troubleshooting

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

 

Heater produces a whistling

1. Turning control knob to HI

1.

Turn control knob to LO

noise when burner is lit

 

position when burner is cold

 

position and let warm up for

 

2.

Air in gas line

2.

a minute

 

 

 

Operate burner until air is re-

 

 

 

 

moved from line. Have gas line

 

3.

Air passageways on heater

3.

checked by local gas company

 

Observe minimum installation

 

4.

blocked

4.

clearances (see page 8)

 

Dirty or partially clogged

Clean burner (see

Cleaning

 

 

burner orifice

 

and Maintenance,

page 16)

 

 

 

 

or replace burner orifice

 

 

 

 

 

Dark residue on logs or inside

1. Improper log placement

1.

Properly locate logs (see In-

of fireplace

2.

Drafts or other air currents

2.

stalling Logs, page 11)

 

Eliminate source of drafts

 

3.

affecting flame pattern

3.

around heater

 

 

 

Air holes at burner inlet

Clean out air holes at burner

 

 

blocked

 

inlet. Periodically repeat as

 

4.

Burner flame holes blocked

4.

needed

 

 

 

Remove blockage or replace

 

 

 

 

burner

 

 

 

 

 

 

 

White powder residue forming

1. When heated, vapors from

1.

Turn heater off when using

within burner box or on adjacent

 

furniture polish, wax, carpet

 

furniture polish, wax, carpet

walls or furniture

 

cleaners, etc. may turn into

 

cleaners or similar products

 

 

white powder residue

 

 

 

 

 

 

 

 

 

Heater produces a clicking/tick-

1. Metal expanding while heating

1.

This is normal with most heat-

ing noise just after burner is lit

 

or contracting while cooling

 

ers. If noise is excessive, contact

or shut off

 

 

 

qualified service person

20

www.desatech.com

110361-01G

Image 20
Contents What to do if YOU Smell GAS Table of Contents Safety InformationSafety Information Poisoning may lead to deathProduct Identification Vent-Free Freestanding Pedestal StoveProduct Features Local CodesUnpacking Air For Combustion VentilationAIR for Combustion Ventilation Determining FRESH-AIR Flow for heater LocationConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsMinimum Wall and Ceiling Clearances See Figure Check GAS TypeClearances to Combustibles Connecting to GAS Supply Installation Items NeededChecking GAS Connections Propane/LPNatural Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Logs Pressure Testing Heater Gas ConnectionsInstalling Blower Accessory GA3750 Installing One-Piece Log set Top ViewInstalling Blower Control Housing Lighting Instructions For Your Safety Read Before LightingOperating Heater Operating Heater Inspecting BurnersCleaning Maintenance Burner Injector Holder and Pilot Air Inlet HoleCleaning Maintenance Service HintsTechnical Service SpecificationsTroubleshooting Observed Problem Possible Cause RemedyMaintenance Cleaning Gas leak. See Warning Statement aboveIllustrated Parts Breakdown Models S26PTA and s26nta ShownParts List Illustrated Parts Breakdown Models S26PTA and s26NtaParts List Replacement Parts AccessoriesCleaning KIT CCK Equipment Shutoff Valve GA5010Parts Central Limited Warranty VENT-FREE GAS Pedestal Stove Warranty InformationKeep this Warranty

S26PTA, S26NTA specifications

Desa S26PTA and S26NTA represent the forefront of agricultural technology, offering robust solutions tailored for modern farming needs. These innovative systems cater specifically to agricultural producers looking to enhance efficiency, streamline operations, and improve yields.

One of the main features of Desa S26PTA is its advanced precision agriculture capabilities. Equipped with state-of-the-art GPS technology, it enables farmers to accurately map their fields, monitor crop health, and apply inputs like fertilizers and pesticides with pinpoint accuracy. This not only conserves resources but also minimizes environmental impact, leading to more sustainable farming practices. Additionally, the S26PTA offers real-time data analytics that helps farmers make informed decisions based on current field conditions.

On the other hand, the S26NTA focuses on nutrient management, delivering a comprehensive solution for soil health. Its integrated sensor technology allows for continuous monitoring of soil conditions, assessing moisture levels, pH, and nutrient content. Farmers can access this data through a user-friendly interface, empowering them to optimize their soil management strategies. By fostering healthier soils, the S26NTA contributes to stronger crop development and increased productivity.

Both the S26PTA and S26NTA leverage Internet of Things (IoT) technologies, connecting various sensors and agricultural equipment. This technological integration provides a holistic view of farming operations, ensuring that farmers can monitor and control their systems remotely. The ability to receive alerts and notifications regarding equipment performance or potential issues is invaluable for proactive management.

Moreover, these systems are designed to be user-friendly, with intuitive interfaces that cater to farmers of all tech-savvy levels. Training and support are also integral parts of the package, ensuring that users can maximize the potential of these advanced technologies.

In conclusion, Desa S26PTA and S26NTA exemplify the evolution of agriculture through technology. Their focus on precision farming, nutrient management, and IoT integration offers powerful tools that enhance productivity and sustainability. As the agricultural sector continues to embrace digital transformation, solutions like these will play a crucial role in shaping the future of farming. Farmers adopting these technologies can look forward to optimized operations, improved crop yields, and a positive environmental impact.