Desa S26PTA, S26NTA installation manual Connecting to GAS Supply, Installation Items Needed

Page 9

Installation

Continued

CONNECTING TO GAS SUPPLY

WARNING: A qualified ser- vice person must connect heater to gas supply. Follow all local codes.

CAUTION: Never connect propane/LPheater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the exter- nal regulator between the heater and propane/LP supply.

WARNING: Never connect natural gas heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

*An CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 26.

For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water. If you do not reduce incoming gas pres- sure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 6. Pointing the vent down protects it from freezing rain or sleet.

CAUTION:Useonlynew,black ironorsteelpipe.Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of volume will occur.

Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 7, page 10).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Check building codes for any special require- ments for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Side View

Back View

Front of

Stove

Unit

Gas Regulator

Inlet Connection

Figure 5 - Gas Regulator Location and Gas Line Access Into Stove Cabinet

Propane/LP

Supply TankExternal

Regulator

Vent

Pointing

Down

Figure 6 - External Regulator With Vent

Pointing Down

110361-01G

www.desatech.com



Image 9
Contents What to do if YOU Smell GAS Safety Information Table of ContentsPoisoning may lead to death Safety InformationVent-Free Freestanding Pedestal Stove Product IdentificationLocal Codes Product FeaturesUnpacking Air For Combustion VentilationDetermining FRESH-AIR Flow for heater Location AIR for Combustion VentilationConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceVentilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsCheck GAS Type Clearances to CombustiblesMinimum Wall and Ceiling Clearances See Figure Installation Items Needed Connecting to GAS SupplyPropane/LP Checking GAS ConnectionsNatural Test Pressures Equal To or Less Than Psig 3.5 kPaPressure Testing Heater Gas Connections Installing LogsInstalling One-Piece Log set Top View Installing Blower Accessory GA3750Installing Blower Control Housing For Your Safety Read Before Lighting Operating HeaterLighting Instructions Inspecting Burners Operating HeaterBurner Injector Holder and Pilot Air Inlet Hole Cleaning MaintenanceService Hints Cleaning MaintenanceTechnical Service SpecificationsObserved Problem Possible Cause Remedy TroubleshootingMaintenance Cleaning Statement above Gas leak. See WarningModels S26PTA and s26nta Shown Illustrated Parts BreakdownParts List Models S26PTA and s26Nta Illustrated Parts BreakdownParts List Accessories Replacement PartsCleaning KIT CCK Equipment Shutoff Valve GA5010Parts Central Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Pedestal Stove

S26PTA, S26NTA specifications

Desa S26PTA and S26NTA represent the forefront of agricultural technology, offering robust solutions tailored for modern farming needs. These innovative systems cater specifically to agricultural producers looking to enhance efficiency, streamline operations, and improve yields.

One of the main features of Desa S26PTA is its advanced precision agriculture capabilities. Equipped with state-of-the-art GPS technology, it enables farmers to accurately map their fields, monitor crop health, and apply inputs like fertilizers and pesticides with pinpoint accuracy. This not only conserves resources but also minimizes environmental impact, leading to more sustainable farming practices. Additionally, the S26PTA offers real-time data analytics that helps farmers make informed decisions based on current field conditions.

On the other hand, the S26NTA focuses on nutrient management, delivering a comprehensive solution for soil health. Its integrated sensor technology allows for continuous monitoring of soil conditions, assessing moisture levels, pH, and nutrient content. Farmers can access this data through a user-friendly interface, empowering them to optimize their soil management strategies. By fostering healthier soils, the S26NTA contributes to stronger crop development and increased productivity.

Both the S26PTA and S26NTA leverage Internet of Things (IoT) technologies, connecting various sensors and agricultural equipment. This technological integration provides a holistic view of farming operations, ensuring that farmers can monitor and control their systems remotely. The ability to receive alerts and notifications regarding equipment performance or potential issues is invaluable for proactive management.

Moreover, these systems are designed to be user-friendly, with intuitive interfaces that cater to farmers of all tech-savvy levels. Training and support are also integral parts of the package, ensuring that users can maximize the potential of these advanced technologies.

In conclusion, Desa S26PTA and S26NTA exemplify the evolution of agriculture through technology. Their focus on precision farming, nutrient management, and IoT integration offers powerful tools that enhance productivity and sustainability. As the agricultural sector continues to embrace digital transformation, solutions like these will play a crucial role in shaping the future of farming. Farmers adopting these technologies can look forward to optimized operations, improved crop yields, and a positive environmental impact.