Desa S26NTA, S26PTA Operating Heater, For Your Safety Read Before Lighting, Lighting Instructions

Page 14

Operating Heater

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orangeflamewillalsobepresent. Openawindowtoventsmell.This will only last a few hours.

1.STOP! Read the safety information, above.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the safety information, column 1. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 19).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 15.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

• If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again.

8.Turn control knob counterclockwise to desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

 

Ignitor Button

Control Knob

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 19 - Control Knob and Ignitor

Button Location

14

www.desatech.com

110361-01G

Image 14
Contents What to do if YOU Smell GAS Table of Contents Safety InformationSafety Information Poisoning may lead to deathProduct Identification Vent-Free Freestanding Pedestal StoveUnpacking Product FeaturesLocal Codes Air For Combustion VentilationConfined and Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsMinimum Wall and Ceiling Clearances See Figure Check GAS TypeClearances to Combustibles Connecting to GAS Supply Installation Items NeededNatural Checking GAS ConnectionsPropane/LP Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Logs Pressure Testing Heater Gas ConnectionsInstalling Blower Accessory GA3750 Installing One-Piece Log set Top ViewInstalling Blower Control Housing Lighting Instructions For Your Safety Read Before LightingOperating Heater Operating Heater Inspecting BurnersCleaning Maintenance Burner Injector Holder and Pilot Air Inlet HoleTechnical Service Cleaning MaintenanceService Hints SpecificationsTroubleshooting Observed Problem Possible Cause RemedyMaintenance Cleaning Gas leak. See Warning Statement aboveIllustrated Parts Breakdown Models S26PTA and s26nta ShownParts List Illustrated Parts Breakdown Models S26PTA and s26NtaParts List Cleaning KIT CCK Replacement PartsAccessories Equipment Shutoff Valve GA5010Parts Central Limited Warranty VENT-FREE GAS Pedestal Stove Warranty InformationKeep this Warranty

S26PTA, S26NTA specifications

Desa S26PTA and S26NTA represent the forefront of agricultural technology, offering robust solutions tailored for modern farming needs. These innovative systems cater specifically to agricultural producers looking to enhance efficiency, streamline operations, and improve yields.

One of the main features of Desa S26PTA is its advanced precision agriculture capabilities. Equipped with state-of-the-art GPS technology, it enables farmers to accurately map their fields, monitor crop health, and apply inputs like fertilizers and pesticides with pinpoint accuracy. This not only conserves resources but also minimizes environmental impact, leading to more sustainable farming practices. Additionally, the S26PTA offers real-time data analytics that helps farmers make informed decisions based on current field conditions.

On the other hand, the S26NTA focuses on nutrient management, delivering a comprehensive solution for soil health. Its integrated sensor technology allows for continuous monitoring of soil conditions, assessing moisture levels, pH, and nutrient content. Farmers can access this data through a user-friendly interface, empowering them to optimize their soil management strategies. By fostering healthier soils, the S26NTA contributes to stronger crop development and increased productivity.

Both the S26PTA and S26NTA leverage Internet of Things (IoT) technologies, connecting various sensors and agricultural equipment. This technological integration provides a holistic view of farming operations, ensuring that farmers can monitor and control their systems remotely. The ability to receive alerts and notifications regarding equipment performance or potential issues is invaluable for proactive management.

Moreover, these systems are designed to be user-friendly, with intuitive interfaces that cater to farmers of all tech-savvy levels. Training and support are also integral parts of the package, ensuring that users can maximize the potential of these advanced technologies.

In conclusion, Desa S26PTA and S26NTA exemplify the evolution of agriculture through technology. Their focus on precision farming, nutrient management, and IoT integration offers powerful tools that enhance productivity and sustainability. As the agricultural sector continues to embrace digital transformation, solutions like these will play a crucial role in shaping the future of farming. Farmers adopting these technologies can look forward to optimized operations, improved crop yields, and a positive environmental impact.