12.Using the four screws previously removed, mount blower assembly to stove by reat- taching blower brackets to rear panel (see Figure 16). Tighten screws securely.

13.Install plastic control knob onto output shaft of speed control housing (see Figure 17). Place speed control housing just inside control com- partment door in front of stove (see Figure 17).

14.Using two screws provided in blower kit, mount blower speed control housing to mount- ing tab in left side of lower control compart- ment (see Figure 18).

15.Check to make sure that the power cord is completely clear of blower wheel and there are no foreign objects in blower wheel.

16.Carefully replace stove top panel. Align holes and replace six screws removed in step 1, page 12.

17.Peel off the backing paper and stick the sup- plied wiring diagram decal on the stove floor as shown in Figure 18.

18.Plug power cord into a convenient 3-prong grounded wall receptacle near the stove.

WARNING:ElectricalGround- ing Instructions: This appliance is equipped with a three-prong (grounding) plug for your protec- tion against shock hazard and should be plugged directly into aproperlygroundedthree-prong receptacle.

Blower

Blower Bracket

Firebox

Top

Figure 16 - Removing Blower Brackets from Stove and Attaching to Blower

19.Using speed control knob, turn blower on and check for operation.

20.All remaining parts from blower kit may be discarded.

Blower Speed

Control Housing

Figure 17 - Installing Blower Control

Housing

Power

Speed Cord

Control

Housing

Control

Knob

WARNING: Never attempt to service heater while it is plugged in, operating or hot. Burns and electrical shock could result. Only a qualified service person should service or repair heater.

If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 105°C wire or it’s equivalent.

WARNING: Label all wires prior to disconnec- tion when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

120 Vac.

 

 

Variable

 

 

 

 

 

60 Hz. .

 

Fan Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

78 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

On

 

 

 

 

 

110/115

 

Black

Black

 

Blower

 

 

V.A.C.

Black

 

 

 

 

Black

Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

White

 

 

 

 

White

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DESA Heating Products, Bowling Green, KY

Wiring Diagram Decal

Figure 18 - Routing Power Cord

110361-01G

www.desatech.com

13

Image 13
Contents What to do if YOU Smell GAS Safety Information Table of ContentsPoisoning may lead to death Safety InformationVent-Free Freestanding Pedestal Stove Product IdentificationLocal Codes Product FeaturesUnpacking Air For Combustion VentilationDetermining FRESH-AIR Flow for heater Location AIR for Combustion VentilationConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceVentilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsClearances to Combustibles Check GAS TypeMinimum Wall and Ceiling Clearances See Figure Installation Items Needed Connecting to GAS SupplyPropane/LP Checking GAS ConnectionsNatural Test Pressures Equal To or Less Than Psig 3.5 kPaPressure Testing Heater Gas Connections Installing LogsInstalling One-Piece Log set Top View Installing Blower Accessory GA3750Installing Blower Control Housing Operating Heater For Your Safety Read Before LightingLighting Instructions Inspecting Burners Operating HeaterBurner Injector Holder and Pilot Air Inlet Hole Cleaning MaintenanceService Hints Cleaning MaintenanceTechnical Service SpecificationsObserved Problem Possible Cause Remedy TroubleshootingMaintenance Cleaning Statement above Gas leak. See WarningModels S26PTA and s26nta Shown Illustrated Parts BreakdownParts List Models S26PTA and s26Nta Illustrated Parts BreakdownParts List Accessories Replacement PartsCleaning KIT CCK Equipment Shutoff Valve GA5010Parts Central Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Pedestal Stove

S26PTA, S26NTA specifications

Desa S26PTA and S26NTA represent the forefront of agricultural technology, offering robust solutions tailored for modern farming needs. These innovative systems cater specifically to agricultural producers looking to enhance efficiency, streamline operations, and improve yields.

One of the main features of Desa S26PTA is its advanced precision agriculture capabilities. Equipped with state-of-the-art GPS technology, it enables farmers to accurately map their fields, monitor crop health, and apply inputs like fertilizers and pesticides with pinpoint accuracy. This not only conserves resources but also minimizes environmental impact, leading to more sustainable farming practices. Additionally, the S26PTA offers real-time data analytics that helps farmers make informed decisions based on current field conditions.

On the other hand, the S26NTA focuses on nutrient management, delivering a comprehensive solution for soil health. Its integrated sensor technology allows for continuous monitoring of soil conditions, assessing moisture levels, pH, and nutrient content. Farmers can access this data through a user-friendly interface, empowering them to optimize their soil management strategies. By fostering healthier soils, the S26NTA contributes to stronger crop development and increased productivity.

Both the S26PTA and S26NTA leverage Internet of Things (IoT) technologies, connecting various sensors and agricultural equipment. This technological integration provides a holistic view of farming operations, ensuring that farmers can monitor and control their systems remotely. The ability to receive alerts and notifications regarding equipment performance or potential issues is invaluable for proactive management.

Moreover, these systems are designed to be user-friendly, with intuitive interfaces that cater to farmers of all tech-savvy levels. Training and support are also integral parts of the package, ensuring that users can maximize the potential of these advanced technologies.

In conclusion, Desa S26PTA and S26NTA exemplify the evolution of agriculture through technology. Their focus on precision farming, nutrient management, and IoT integration offers powerful tools that enhance productivity and sustainability. As the agricultural sector continues to embrace digital transformation, solutions like these will play a crucial role in shaping the future of farming. Farmers adopting these technologies can look forward to optimized operations, improved crop yields, and a positive environmental impact.